Get complete information related to latest Fuse Alarm System Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Fuse Alarm System Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Fuse Alarm System Tenders.
Tender For electronic thermostat sensor to rdso specification no: rdso/pe/spec/ac/0020,latest alt. make: venusbasio / analog electronics/a. paul instruments. note: 1) item should be suitable for 2t capacity roof mounted cab ac of make daulatram / fedders lylord /sidwal fitted on conventional electric locos to rdso specification no -rdso/2007/el/spec/0055 rev.2 of nov 2007/revised on 07.10.2014. 2) one sample to be got approved before effecting bulk supply.
Tender For supply of spares for trimos height gauges - measuring interface , display vt mt mestra touch vectra , suspension sensor , machine electronic card , connection cable instrument , electronic card of the measuring system , new v line charges
Tender For supply, installation and commissioning of electronic card module and boost pressure sensor for 500 kva perkins make diesel generator set at jalandhar terminal
Tender For supply of sitc of 7tr copeland model zr108kce scroll compressor , providing nitrogen pressure testing and vacuumising the entire refrigerant system , supplying and charging of refrigerant gas r407 in the existing ac package unit , sitc of blower motor electronic commuted 3 phase 380 to 480 v 50 60 hz 3 point 1 kw 1560 rpm for emerson make 7 tr bottom feed precision ac , sitc condenser motor with axial fan blade , electronic expansion valve driver unit evd evolution user interface unit without display of carel make , expansion valve carel make , high pressure gas solenoid valve unit suitable for emerson make 7 tr hpac , lp cut out switch for emerson make 7 tr hpac , hp cut out switch for emerson make 7 tr hpac , crankcase heater for scroll compressor of copeland model zr108kce , ioc card controller icom board for emerson make 7 tr hpac , evd pressure switch for emerson make 7 tr hpac , sitc of 4p 63a 25ka breaking capacity mccb 3vti siemens or ss , fuse set pcb card , contactor 4 pole 32 amps mcx03 coil supply 220v , contactor addon block , return air sensor , control transformer primary 380 v to 415 v secondary 1 0 to 22 v 2a sec 2 0 to 24 v 6 a , attending defects in control wiring , sitc of 7 tr copeland model zr108kce scroll compressor , providing nitrogen pressure testing and vacuuming the entire refrigerant system , ioc card controller ie icom board for emerson make 15 tr hpac , lp cut out switch for emerson make 15 tr hpac , hp cut out switch for emerson make 15 tr hpac , v belt for blower of 15 tr emerson make hpac unit , 4 pole 32 amp contactor for blower motor , 3 pole 40 amp contactor for compressor , rewinding of blower motor rating 3 phase 415 v induction motor 3 hp 1430 rpm , condenser motor with axial fan blade , attending defects in control wiring , providing nitrogen pressure testing and vacuumising the entire refrigerant system , electronic expansion valve driver unit evd evolution user interface unit without display of carel make suitable for stulz make 7 tr hpac , high pressure gas solenoid valve unit suitable for stulz make 7 tr hpac , lp cut out switch for stulz make 7 tr hpac , hp cut out switch for stulz make 7 tr hpac , sitc of condenser motor with axial fan blade and safety grill , crankcase heater for scroll compressor , sitc of precision ac display unit assembly suitable for 7tr stulz make precision ac , sitc of 7 tr copeland, model zr108kce scroll compressor , ioc card controller i.e. icom board for emerson make 15 tr hpac , 4 pole 32 amp, contactor for blower motor , rewinding of blower motor, rating 3 phase 415 v induction motor, 3.0 hp, 1430 rpm , electronic expansion valve driver unit evd evolution user interface unit without display of carel make suitable for stulz make 7 tr hpac. , high pressure gas solenoid valve unit suitable for stulz make 7 tr hpac.
Tender For purchase of various apparatus/instruments required for department of chemistry, chaudhary ranbir singh university, jind - stirrer the stirrer should be made up of ceramic coated aluminium alloy top with digital speed and temperature control. the stirring speed should be 50-1500 rpm or better. the stirrer should be operational up to a temperature range of 300oc with an accuracy of 1.0oc and ip 42 protection class. the input power should be 600 w or above. the stirrer should be supplied with hemispheric bowl (100 ml= 1 no; 250 ml= 1 no) to replace oil baths and mantles in order to perform clean and safe analysis with round bottom flasks., electronic balance the electronic balance should have a maximum weighing capacity of 200 g or more with a resolution and repeatability of 0.1 mg, and a response time of 5 sec or better. the system should have automatic internal calibration with touch screen display. the system should have internal database capacity of 2500 or more with multiuser password protection feature. , vacuum pumpthe pump should be operational at a maximum power of 65 w or more with a max. vaccum of 99 mbar or more. the pump should be fitted with vacuum and filter cartridge., hot air oventhe inner chamber should be made of stainless steel and the outer chamber should be m.s powder coated. the maximum capacity of the oven should be 100 ml or more. the operational temperature should be between ambient to 250 oc or more with a temperature accuracy of 1o c. pid based digital temperature control., double distillation unitthe unit should be pyrogen free with a distillation water output capacity of 1.5 l/h. the minimum cooling water requirement should be 1lt/min. auto-power cut facility in case of halted supply of water., circulating oil baththe oil bath should be made up of stainless steel with 4 digit 7 segment led display for temperature and time. the bath should have s.s perforated tray for holding flasks. the bath should have a capacity to accommodate flask of 1l. the working temperature range should be +5 to 240 oc (0.1 oc increment) with a temperature stability of 1oc., water baththe water bath should have a capacity of 20 l within built water level sensor. the bath should be made up of stainless steel and supplied with 8 concentric rings. the bath should have digital temperature control with pt100 sensor. the system should have stirring capability with ptfe magnetic bars. , ph conductivity meter operational between a ph range of -2 to 16.00 with a resolution of 0.01 ph and an accuracy of 0.02 ph. 5 points calibration. the ec range should be in between 0.00 to 29.99 s/cm, uv cabinet operational at two uv wavelengths (254 and 365 nm). the cabinet should also be equipped with one visible light. the external body should be coated with ms powder/epoxy., flame photometerapplication: the flame photometer is used for qualitative and quantitative determination of several cations, especially for metals that are easily excited to higher energy levels at flametemperature. these metals include na+, k+, ca2+, ba2+ and li2+.specification requirementmeasuring range na+: 0 to 99.9 ppm k+:0 to 99.9 ppm ca2+ :0-99.9 ppmli2+: 0 to 99.99 ppmsensitivity na+= 0.1 ppmk+ = 0.1 ppmspecificity less than 0.5% interference when concentrations are equal to test sample concentrationsgas control-adjustable with knobsignition system-auto ignition systemflame failure-auto detectiongas cut off-automaticreproducibility-less than 1% coefficient of variation for 20 consecutive samplesusing 10 ppm na set as maximum standardlinearity-less than 1%display led, 12.5 mm (1/2")fuel supply-high-grade propane/butane mixture regulated at approximately30 psiair supply-6 l/min at 12 psi; oil and moisture freerecorder-output 0.05 to 5 v (switchable)operating manuals, service manuals, other manuals should provide user, technical and maintenance manuals in english language list of equipment and procedures required for local calibration and routine maintenance service and