Get complete information related to latest Fuse Set Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Fuse Set Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Fuse Set Tenders.
Tender For supply of smc dt metering box in 63kva, box size dimensions- h=700mm, w=480mm, d=210mm, thi ckness of box= 3.5+-5%, color - off white, general tolerance- 10%+_. with internal accesories (200a 415v porcelain kit ket fuse 04nos). the meter box is crafted with anti corrosive, rust proof, dust proof, waterpro of, uv protected and flame-retardant high-grade material that should have great dielectric adn mechanical strength properties. made out of moulding compound by process of hot press compressing moulding, confir ming to is:13410.240x190x4 mm wooden board for fixing meter., 600x400x4mm hylam sheet for meter & f use mounting,32mm pvc gland 03nos with dummy. removable frp angle for sheet mount, mbx40 gi eart hing bolt with 02nut, 2 plain washer .1 spring washer. 20nos on both side with inside wire mesh, cable hol ding clamp -02nos outside. rubber gasket for waterproof. 04nos door closing clamp, foldable handle 1nos, , mszp box mounting flat 02nos per box. mszp pole clamp 02nos per box. acceptable bra nd-epp, sintex, havells, l&t, c&s, indooasion, abb, hpl and similar make [ warranty period: 12 mon ths after the date of delivery ]
Tender For corrigendum : construction of lt fuseset and fencing work for distribution transformers, in the area of e.d.s.d.-ii, hasanganj under the e.d.d. v, hasanganj, unnao. under business plan year 2023-24.
Tender For supply of various types of power & control fuse at wtps, gsecl. - hrc fuse 2 amp for one to one replacement of ee make type ns 2., hrc fuse 4 amp for one to one replacement of ee make type ns 4., hrc fuse 6 amp for one to one replacement of ee make type ns 6., hrc fuse ns10, rating 10 amp., hrc fuse 16 amp. type ca1/ ns, e.e.make hrc fuses 25amp type-ns-25, hrc fuse 16 amp for one to one replacement of ee make type tia-16., hrc fuse 25 amp for one to one replacement of ee make type tia-25., hrc fuse 32 amp for one to one replacement of ee make type tia-32., hrc fuse link tia-50, 50 amp, hrc fuse link tia-63, 63 amp, din type fuse link 16ampx415v type size-00, din type fuse link 25ampx415v type-size-00, din type fuse link 32ampx500v/415vx80ka-ty nh00, hrc fuse 36 amp vsb 36,ee make (gec altron), din type fuse link 50ampx415v type size-00, hrc fuse (din type) 500v ac, s.c. breaking capacity 120ka, size-00, rating 125 amp, type:- 3na3 832 - 7y . siemens make, din type fuse link 63ampx415v/500vx80ka nh 0/1 typ, din type fuse link 80ampx415v type size-1, din type fuse link 125ampx415v type-size-1, hrc fuse 200 amp for one to one replacement of siemense make din type 500v ac s.c. breaking capacity 120ka size-1 rating 200 amp type: 3na3 140 - 7y., siemens make fuse base ( din ) 250 a rated type 3nh3-230, simence make hrc fuse (din type)500vac /120 ka400 amp 3na3 lv hrc fuse link , nh2 ,3 na3 260 - 7y, hrc fuse 2 amp."d" type 500 vac bl make, hrc fuse 4 amp."d" type , 500 v ac, hrc fuse 6 amp " d " type , 500 vac, porcelain kit kat fuse 63 amp, 415 v , ac, porcelain kit kat fuse 100 amp, 415 v , ac, porcelain kit kat fuse 200 amp, 415 v , ac, moulded bakelite fuse fittings , 2 amp to 16 amp , type ns h , e.e. /g.e. make ,440 v ac 5 , bs 88 (bottom& top ), moulded bakelite fuse fittings , 32 amp , type sm-32 h , e.e. /g.e. make ,415 v , (bottom& top ) , is 9224 part i, moulded bakelite fuse fittings , 63 amp , type sm - 63 h , e.e. /g.e. make ,440 v , (bottom& top ), hrc fuse 6 amp for one to one replacement of l&t make type hf cat no 90146., hrc fuse 16 amp for one to one replacement of l&t make type hf cat no 90150., l&t hrc fuse link hf-32 amp,500 v,sf-90142, fuse base type hco suitable for hf- 32 a fuses, hrc fuse 6 amp for one to one replacement of siemense make din type 500v ac s.c. breaking capacity 120ka size-000 rating 6 amp type:- 3na3 801 - 7y., hrc fuse 32 amp for one to one replacement of siemense make din type 500v ac s.c. breaking capacity 120ka size-000 rating 32 amp type 3na3 803 - 7y., moulded backelite fuse base/top for 415 volt a.c.50 hz.suitable for 02 to 32 amp ns type fuse link. list no- nsh and code reference no-sff8111000 of g.e make.bs type fuse holder., hrc fuse 25 amp for one to one replacement of siemense make din type 500v ac s.c. breaking capacity 120ka size-000 rating 25 amp type: 3na3 810 - 7y., hrc fuse (din type) 500v ac, s.c. breaking capacity 120ka, size-1, rating 63 amp, type:- 3na3 122 - 7y . siemens make, hrc fuse 63 amp for one to one replacement of siemense make din type 500v ac s.c. breaking capacity 120ka size-000 rating 63 amp type: 3na78220rc, hrc fuse 80 amp for one to one replacement of siemense make din type 500v ac s.c. breaking capacity 120ka size-000 rating 80 amp type: 3na3 824 - 7y., e.e.make fuse link 630a/500v/80ka/g-ii/vst/630 size 3 skd 8350630, rating-315 amp,size-1 ,breaking capacity-100 ka ,voltage-415 v ac,mounting-din type blade contact with indicator for fuse failure. utilization category-gg, rating-250 amp,size-2 ,breaking capacity-80 ka ,voltage-500 v ac,mounting-din type blade contact with indicator for fuse failure. utilization category-gg, hrc fuse 100 amp for one to one replacement of ee make type vsb-100., cylindrical hrc fuse 2 amp, voltag-500v,class of operation-gg, breaking capacity 120ka, size 10x38., cylindrical hrc fuse 4 amp, voltag-500v,class of operation-gg, breaking capacity 120ka, size 10x38., cylindrical hrc fuse 6 amp, voltag
Tender For corrigendum : for running contract for hon,ble sansad nidhi/vidhayak nidhi and other deposit works under edd-budaun (semi turnkey). - cartage of following material from store center nawada, budaun to je store/je store to site of work including loading & unloading at both ends maximum distance up to 30 km., a) pcc pole 8.5 mrt long/st pole 11 mtr long., b) 11 kv xlpe cable of 3x70/3x120/3x185/3x300 sq.mm., c) 250/400 kva t/f., d) 11 kv ct/pt unit of different size, e) 11 kv jointing kit of different size, f) 11 kv pilfer proof cubical of different size, g) lt abc cable of size 1x16, 3x50, 3x95, 3x120 sq.mm., cartage of line material (11 kv pin insulator, disc insulator, stay set, cross arm, gi wire, earthing rod, ms channel, ms angle, etc) from store centre to dump site & then dump site to site of work on day to day basis, including loading & unloading at both ends maximum distance up to 30 km., cartage of 10 kva & 25 kva transformer from store centre to site of work including loading & unloading at both site, the work of safe carriage 11 kv o/g vcb store center nawada budaun to work of site distance up to 0 to 30 km including safe loading & unloading., cartage of 63 kva to 100 kva transformer from store centre to site of work including loading & unloading at both site., earthing of each 11 kv line pole & t/f properly after drive of electrodes if size 20mmx250mm and connection the earthing point with gi wire., erection of pcc pole 8.5 mtr long after digging a pit of size 1.20 x 0.60 x 1.6 mtr in all type of soil including back filling of the pole with proper ramming after completion of work., erection of stp pole 11 mrt long after digging a pit of size 1.20 x 0.60 x 1.6 mtr in all type of soil including back filling of the pole with proper ramming after completion of work., fabrication and fixing of all 11 kv h.t/l.t. line accessories., erection of double pole on pcc pole 8.5 mtr/stp 11 mtr. long after digging of pit of required size including fabrication and fixing of top channel, droper channel & base channel alongwith, fixing all 11 kv accessories, fuseset 11 kv pin insulators and making connection properly., construction of new plinth for 250/400 kva as per uppcl norms, mounting of 250/400 kva t/f on plinth as per uppcl norms, providing and fixing wiremess fencing for 250/400 kva, erection/installation of following of vcb o/g in consumers site and cable joint of the panel to including earthing, grouting, anchor bolt of panel of making/repairing of pocket for cable to insert in panel form trench and fixing taping of busbar with wiring for ac,dc connection including providing ac and dc supply., chemical earthing for 250/400 kva t/f neutral and body complete, chemical earthing for vcb o/g, mounting of 10 & 25 kva t/f with proper jumping of ht side and fixing of cable on lt. side of t/f making connection properly., mounting of 63 & 100 kva t/f with proper jumping of ht side and fixing of cable on lt. side of t/f making connection properly., mounting of ct/pt unit with proper jumping of ht side and fixing of cable on lt. side of meter cubical properly, fixing of meter cubical as per uppcl norms, making a section pole to exist pole after fabrication & fixing of t channel fixing of all 11 kv accessories., erection of stay rod complete after digging a pit of size 1.20 x 0.60 x 1.6 mtr and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming., laying lifting stringing of proper sagging of acsr weasel/rabbit/dog conductor for 3 phase, 3 wire 11 kv line including binding & jumpering properly., laying lifting stringing of proper sagging of 11 kv xlpe cable of 3x70, 3x120, 3x185, 3x300 sq.mm., laying of underground 11 kv xlpe cable of 3x70, 3x120, 3x185, 3x300 sq.mm. sizes with open trench by brick & sand as per uppcl norms., filling the 11 kv jointing kit (joint kit providing by c