Get complete information related to latest Fuse Wire Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Fuse Wire Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Fuse Wire Scrap Tenders.
Tender For corrigendum : replacement of security equipment installations at dmde office complex under ge i rnd kanchanbagh, hyderabad - supply and fixing of electric fencing - 520 rm as specified below as per site requirement including taking down existing fencing with all connected accessories viz. energizer, boom barrier, hydraulic tyre killer, turnstile gate, swing lane barrier, fencing posts, fencing wire, insulators, door frame metal detector etc, complete all as specified and directed by engineer-in-charge., (a) general description(a) this scope involves, design, supply, installation, testing and commissioning of a non-lethal high security. electrical fencing for the purpose of deterrence, detection, and movement control of people / unwarranted trespassing into the premises for 520-meters perimeter length.(b) anyone who touches the power fencing when the system is armed shall be repelled by a short, sharp, painful, but safe pulsed dc high voltage shock. alarms shall be generated when someone touches, tries to climb through or tampers with the power fencing system., (c) the electric fencing shall be divided into two zones.(d) this system should be able to alert security personnel of an attempted intrusion and identify the zone around the perimeter of the site.(e) the electric fence is to be installed on the existing wall and the height of the fence will be 1.1 meters from top of the wall with 11 nos. of fence wires having 100mm gap between adjacent wires and it measure 1mtr.(f) electric fence posts are to be hot dip galvanized., (g) distance between strain fence posts spacing shall not exceed 50-meter nominal.(h) distance between intermediate fence posts spacing shall not exceed 3-meter nominal.(j) the electric fence shall incorporate uv stabilized intermediate post insulators.(k) warning signs shall be mounted around the fence line at intervals not exceeding 10m or at every turn on the physical fence.(l) dual zone fence energizer shall be installed to create 2 zones at site., (m) one dual zone led keypad shall be connected to fence energizer for local control and programming purpose.(n) a touchscreen controller should be placed in control room. fence energizer should communicate with touch screen controller over rs485 network.(o) the space between adjacent wires on the electric fence shall be no more than 10cm.(p) anti-climb configuration at strain points shall be provided. electric fence wire shall be looped around the strain post and connected back onto itself.(q) all high voltage impulse wiring shall be run in conduit separate from any other wiring.(r) the fence energizer shall be mounted in the weatherproof enclosure.(s) the energizer should comply with iec 60335-2-76 and is302-2-76 standards., (b) technical specification (electric fence system):energizerthe fence energizer should have the following minimum features: energizer should be dual zone with independent zone control. energizer should communicate with control room on rs485 network. energizer should have lcd display with background colours which changes according to the status of the energizer. green colour should indicate that all is fine, orange indicate that attention is required and red indicates an alarm condition., energizer should display the following information when specific codes are inserted from keypad: fence health on a scale of 1 to 9 for each zone independently, fence output voltage, fence return voltage, energy stored, capacity used and battery voltage. output energy 3.7 joule with 500 ohms load. pulse interval 1 sec. pulse duration should be less than 0.1ms. energizer should have apt - adaptive power technology functionality. which means the energizers should offer a unique technology to detect how much power a fence can accept and handle before it starts to arc and waste energy. this maximises the power on the fence and minimises false alarms., individual high voltage transformer for each zone. magnetic tag switch should be provided for on/off the ene
Tender For supply of supply of 3d printed reinforced concrete panels along with steel , supply of box sections of size 100x100x5mm , supply of 16mm tmt bars , pcc solid block class a bricks , stone patti slab each of size 900x300x50mm thick , paver block m 20 grade 60mm thickness , flexible polyurethane foams sealant 750ml , exterior weather proof paint , ms loop hole of size 900x400mm , ms door of size 900x1850mm , sand bag 18 inch x34 inch hdpe as per is 11652 , pbs roll , bitumen primer , opc 53 grade cement , well graded sand , all in one aggregate , 0 point 5 mm thick metal deck ppgi sheets , 12 mm tmt rebar fe 500 grade , binding wire , steel cutting blade 4 inch dia , distemper oil emulsion obd , w2 panel , clay bricks fly ash brick aac blocks pcc block cm 1colon 4
Tender For supply of 215mm air washing gun high pressure , metal air dust blow gun , digital insulation tester , air impact adapter , magnetic socket organizer , cordless led flexibal inp light , electrician scissor , hak saw frame with 06 x blades , hbl bty vent value check up complete set , sliding trolley , hydrometer , distill water plant 5 to 6 ltrs , stanley 10 bits screwdriver , clamp meter , bosch screw driver set , led flood light 200w , tri pod stand for lights , 2.5 mm 2 core copper wire , compressor hose pipe rubber upto 300psi
Tender For tender for supply of electrical items - 20/36 watt led tube fitting , non integral type , 4x1 feet length having minimum luminous efficacy of 3600 lumen/watt , 9/10 w led lamp having minimum luminous efficacy of 100 lumen/ watt , 90-95 watt led street light luminaire with ip 66 protection and having minimum luminous etticacy 120 lumen/watt , 40-45 watt led post top lumiaire with ip 65 protection , 12 watt recessed/ surface mounted round led light fitting , having luminous efficacy of minimum 199 lm/w , 100 watt led flood light luminaire with ip 66 protection and having minimum luminous efficacy 120 lumen/watt. , surface/recess mounted 600x600 mm led light fitting , 36 watt having/luminous efficacy , recessed/ surface mounted round led light fitting , 18 watt having luminous efficacy of minimum 100 lm/w , 450 mm sweep pvc blade wall fan (heavy duty) , 1200 mm sweep bee e star rated , ceilling fan with brush less direct current (bldc) motor , 225 mm sweep light duty metallic body exhaust fan including louvers , fancy wall bracket fitting along with 9w retrofit led lamp , 5/6 a modular switch , 15/16 a modular switch , 3 pin 5/6 amp socket outlet , 6 pin 15/16 amp socket outlet , ac starter switch 25 amp , 5/6 a , 3-modular switch socket combined box , 5/6 amp , 3-pin plug top , 15/16 amp 3-pin plug top , stepped type modular fan regulator (2m) , call bell , modular call bell pushy , iron screw 40 mmx 6 mm , pvc gitti (1.5 inch) , cable clip with metal nails (8/10/12 mm) , casing capping (25x16 mm) , 1 sq. mm frlsh copper wire , 90 metre roll , 1.5 sq. mm. frls copper wire , 90 metre roll , 2.5 sq. mm frls copper wire , 90 metre roll , 4 sq. mm. fels copper wire , 90 metre roll , 3- core 6 sq. mm btc cable , 3-core , 1.5 sq. mm unarmoured copper cable , 3-core , 2.5. sq. mm unarmoured copper cable , 3-core , 4 sq. mm unarmoured copper cable , 6 - 32 amps single pole c miniature circuit breaker , 2.5 mfd fan capacitor , 3.15 mfd fan capacitor , pvc black tape , ampere tape/ bitumen tape , 33 kv lightening arrestor gl clamps bolts and nuts with washers , 36 kv 20 ka , class - 1 , 50 hz , 33 kv pin insulator with pin washers and nuts , 33 kv drop out fuse element , 63 amp , single phase energy meter , 5-30 amp , 3- phase energy meter , 10-60 amp , 9-10 watt led mirror light fiting having luminous efficacy of minimum 100 lm/watt , heating element of 15/25 ltrs capcity water heater , brass batten holder , 15/16 a , 3- modular switch socket combined box , 2 pin male female adapter plug top , casing pin , 6 mm x 75 mm steel fastner , 40 amps dp c miniature circuit breaker , 63 amps tpn c curve , miniature circuit breaker , 20 a wire connector , 400 amps , 33 kv drop out fuse connector
Tender For corrigendum : supply of m4 x 1p x 25 mm lg. hex. hd. screw with nut & 2-nos. washer, matl. is: 1367, cl. 4.6 & 4, length-75mm(,pvc flexible pipe, size 1/2 inch. required for all type of single phase machine. make-reputed.,15 amp. 3 core flex. pvc copper wire, 3core, 1.5sqmm pvc insulated flexible cable. make-mescab,socket 20 amp 3 pin, required for all single phase machine. make- schnieider, model elctra as20.,socket metal 10 amp, required for all single phase machine. make- schnieider, model elctra as10.,20 amp plug (metal) , 3 pin, required for all single phase machine. make- schnieider, model elctra ap20,10 amps metal plug, required for all single phase machine. make- schnieider, model elctra ap10.
Tender For corrigendum : supply of copper conductor, main switch and other electrical materials at contai (a-m) sub-divisional store under tamluk (a-m) division under non-plan programme 2024 - 2025. - 63 amps ac tpn sheet metal enclosed rewireable type fuse main switch 415 volts 3 phase 50 cycles ac supply conforming to is 60947, 32 amp ac tpn sheet metal enclosed re-wireable type fuse, main switch, 415 vlts, 3 phase, 50 cycles ac supply confirming to is 13947(part-3) 1993., fusewire for 63 amps. as per sample., 20 swg tinned copper fusewire -32 amp. as per sample., 10 sq mm. 3 core flexible copper conductor (flexible) pvc/xlpe insulated heavy duty industrial (sheathed), 1100 volts grade for earthing of electric installation on barge.conforming to is; 1554 ( part i & ii) & is : 7098 (part i & ii) isi marked., 3core x2.5 sq.mm copper cable (flexible) pvc/xlpe insulated heavy duty industrial (sheathed), 1100 volts grade.conforming to is; 1554 ( part i & ii) & is : 7098 (part i & ii) isi marked. make: havells/ finolex/ polycab& equivalent reputed makes., voltmeter (0-500 volt) (as per sample), magnetic no volt coil (dry type) make bmc (as per sample), magnetic over load relay 28-35 amp for make- bmc starter (as per sample), terminal plate with 6 nos bolts ,12 nos nut and washer(20hp kirlosker motor) (as per sample), gi earthing rod(20 swg ) (as per sample), gi earthing wire (10 swg)(as per sample), pvc insulated1.5 sqm single core copper wire- 1.1kv , isi marked as per is694, fr grade, line analog electic tester 6. as per sample., 15 amp male plug (as per sample), 15 amp. female plug (as per sample), bulb holder (as per sample), 9 watt- white led bulb (as per sample), 18 watt - white led bulb (as per sample), flexible electric wire 2 core pvc coated any make brand. as per sample., pvc insulation tape- 1.80cm x 9m x 0.125 mm make: steelgrip. as per sample., electrical plier with wire cutter any make brand (as per sample), wooden pannel board (6x 4x1 " 2) with coat of panting of app.quality (as per sample), dashpot oil 50ml (as per sample)