Get complete information related to latest Galvanized Pipe Sale Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Galvanized Pipe Sale Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Galvanized Pipe Sale Tenders.
Tender For supply of spares for filter water and chlorination pump - lock nut, part no. 2 for filter water pump make: sam turbo industry pv.ltd., model: vo 65/200+chc, cap-106 cu.m/hr, head-46.3 m as per enclosed drg-850-06/tm/0/3083-r-0 earlier pump s.no.:417-418 plant tag no-3,4-7151-p#1001 & 1002, lock washer, part no. 3 for filter water pump make: sam turbo industry pv.ltd., model: vo 65/200+chc, cap-106 cu.m/hr, head-46,3 m as per enclosed drg-850-06/tm/0/3083-r-0 earlier pump s.no.:417-418 plant tag no-3,4-7151-p#1001 & 1002 , drive column pipe-i & ii (1 set 2nos), part no-17 & 17a for filter water pump make: sam turbo industry pv.ltd., model: vo 65/200+chc, cap-106 cu.m/hr, head-46.3 m as per enclosed drg-850-06/tm/0/3083-r-0 earlier pump s.no.:417-418 plant tag no-3,4-7151-p#1001 & 1002 , pump column pipe-1 & ii (1 set=2nos) part no-17.1 & 17.1a for filter water pump make: sam turbo industry pv.ltd., model: vo 65/200+chc, cap-106 cu.m/hr, head-46.3 m as per enclosed drg-850-06/tm/0/3083-r-0 earlier pump s.no.:417-418 plant tag no-3,4-7151-p#1001 & 1002, delivery pipe assembly, part no-25 & 3 (1 set2nos) for filter water pump make: sam turbo industry pv.ltd., model: vo 65/200+chc, cap-106 cu.m/hr, head-46.3 m as per enclosed drg-850-06/tm/0/3083-r-0 earlier pump s.no.:417-418 plant tag no-3,4-7151-p#1001 & 1002, coupling sleeve set (1 set consist of :-coupling sleeve-1 no., coupling ring-2 nos. & coupling nut-2 nos.), part no-19,18 & 22 for filter water pump make: sam turbo industry pv.ltd., model: vo 65/200+chc, cap-106 cu.m/hr, head-46.3 m as per enclosed drg-850-06/tm/0/3083-r-0 earlier pump s.no.:417-418 plant tag no-3,4- 7151-p#1001 & 1002, shaft sleeve (p.end), part no-31 for filter water pump make: sam turbo industry pv.ltd., model: vo 65/200+chc, cap-106 cum/hr, head-46.3 m as per enclosed drg-850-06/tm/0/3083-r-0 earlier pump s.no.:417-418 plant tag no-3,4-7151-p#1001 & 1002, bush bearing (pump), part no-32 for filter water pump make: sam turbo industry pv.ltd., model: vo 65/200+chc, cap-106 cum/hr, head-46.3 m as per enclosed drg-850-06/tm/0/3083-r-0 earlier pump s.no.:417-418 plant tag no-3,4-7151-p#1001 & 1002 3, circlip, part no. 14a, part no-14a for 6 filter water pump make: sam turbo industry pv.ltd., model: vo 65/200+chc, cap-106 cu.m/hr, head-46.3 m as per enclosed drg-850-06/tm/0/3083-r-0 earlier pump s.no.:417-418 plant tag no-3,4-7151-p#1001 & 1002, gasket (impeller/ sleeve), part no-40 6 for for filter water pump make: sam turbo industry pv.ltd., model: vo 65/200+chc, cap-106 cu.m/hr, head-46.3 m as per enclosed drg-850-06/tm/0/3083-r-0 earlier pump s.no.:417-418 plant tag no-3,4-7151-p#1001 & 1002, gasket (impeller nut), part no-41 for 6 filter water pump make: sam turbo industry pv.ltd., model: vo 65/200+chc, cap-106 cum/hr, head-46.3 m as per enclosed drg-850-06/tm/0/3083-r-0 earlier pump s.no.:417-418 plant tag no-3,4-7151-p#1001 & 1002, coupling set-dia.: 180 (with rubber bush & pin) for filter water pump make: sam turbo industry pv.ltd., model: vo 65/200+chc, cap-106 cu.m/hr, head-46.3 m as per enclosed drg-850-06/tm/0/3083-r-0 earlier pump 1 s.no.:417-418 plant tag no-3,4-7151-p#1001 & 1002, drive shaft, part no.16 for filter water 2 pump make: sam turbo industry pv.ltd., model: vo 65/200+chc, cap- 106 cu.m/hr, head-46.3 m as per enclosed drg-850-06/tm/0/3083-r-0 earlier pump s.no.:417-418 plant tag no-3,4-7151-p#1001 & 1002, pump shaft, part no.28 for filter water 2 pump make: sam turbo industry pv.ltd., model: vo 65/200+chc, сар-106 cu.m/hr, head- 46.3 m as per enclosed drg-850-06/tm/0/3083 earlier pump s.no.:417-418 plant tag no-3,4-7151-p#1001 & 1002, impeller, part no-36 for filter water pump make: sam turbo industry pv.ltd., model: vo 65/200+chc, cap-106 cu.m/hr, head-46.3 m as per enclosed drg-850-06/tm/0/3083 earlier pump s.no.:417-418 plant tag no-3,4-7151-p#1001 & 1002 , wearing ring (casing), part no-3
Tender For various repair jobs of emd - overhauling/dismantling of the existing w ater drainer by isolating the drainer by putting blank plate after isolation valve. purging/removal of trapped gas from the seal pot/pipe line by injecting st eam/nit rogen. revisioning of all parts & cleaning of pot. if required, the complete seal pot w ith pipe line has to be new ly fabricated & erected as per the instruction of o.a. or as per draw ing. after erection, testing of pot by injecting st eam/nit rogen and de-isolation/commissioning. the condensate pipe from w ater drainers has to be laid to the nearest storm w ater manhole or as directed by o.a.s representative. painting of w ater drainer and pipes to be done after the erection job , "technical cleaning of gas pipeline water drainers. the w ork involves closing/blanking of valves, st eam purging of pipe/drain pot and opening of f langes of seal pot and removal of muck/deposit from pots, revisioning of gas inspection valve,w ater filling valves,condensate valves. fixing of new packing and tightening of f langes. filling of w ater in the seal pot and de-blanking of w ater drainer/opening of valves. checking for any leakages and rectification of the same " , the job involves cutting/dismantling of corroded structures like column, platforms, w alkw ays, staircases etc. at height. before cutting of any structure, the nearby pipe lines or any other equipment to be supported f irst. the dismantled structures should not be throw n from height. all the dismantled structure to be kept at one place as directed by o.a.s representative for disposal by bsp , the job involves fabrication of st eel structures like column, platforms, w alkw ays, staircases etc. by type 1 electrode, as per approved draw ing / specification or as directed by oa/oa¿s representative complete in all respect including painting. fabricated structures w ill have to be erected by the contractor at height as per the direction of operating authority , the job involves w elding of tack w elded pipes, gland compensators, disc compensators, flanges, st eel structures, gas pipeline equipment, plates, pipes, structures w ith type 1 w elding electrodes , dismantling of gas pipe line or any other pipe line by cutting, including handling and stacking, cutting into pieces and sections as directed by oa/oa¿s representative & stacking at designated location. before cutting the nearby pipe lines/platforms/equipment to be supported. all dismantled structural items to be kept at a particular place, as show n by o.a.s representative for disposal by bsp , job involves erection of fabricated/available pipes at locations show n by o.a./o. a' s representative, including dia. 100mm at heights. erection job involves, lifting of standard length of pipes supplied by bsp free of cost, w elding w ith the existing pipes/valve f langes and testing of pipe w ith st eam/nit rogen and defect rectification w ith type i electrode. any accessories like bleeder pipe, drainer pipe, purging nipples, valves,compensators, saddle supports etc. also to be erected, as directed by o.a , fabricated/available pipes at locations show n by o.a./o.a. s representative, above dia. 100mm and up to dia. 200mm at heights. erection job involves, lifting of standard length of pipes supplied by bsp free of cost, w elding w ith the existing pipes/valve f langes and testing of pipe w ith st eam/nit rogen and defect rectification w ith type i electrode. , fabricated/available pipes at locations show n by o.a./o.a. s representative, above dia. 200mm and up to dia. 500mm at heights. erection job involves, lifting of standard length of pipes supplied by bsp free of cost, w elding w ith the existing pipes/valve f langes and testing of pipe w ith st eam/nit rogen and defect rectification w ith type i electrode. any accessories like bleeder pipe, drainer pipe, purging nipples, valves, compensators, saddle supports etc.also to be erected, as directed by o.a. , overhauling of valves up to d
Tender For providing of custom bid for services - various repair jobs of emd - overhauling/dismantling of the existing w ater drainer by isolating the drainer by putting blank plate after isolation valve. purging/removal of trapped gas from the seal pot/pipe line by injecting st eam/nit rogen. revisioning of all parts & cleaning of pot. if required, the complete seal pot w ith pipe line has to be new ly fabricated & erected as per the instruction of o.a. or as per draw ing. after erection, testing of pot by injecting st eam/nit rogen and de-isolation/commissioning. the condensate pipe from w ater drainers has to be laid to the nearest storm w ater manhole or as directed by o.a.s representative. painting of w ater drainer and pipes to be done after the erection job , "technical cleaning of gas pipeline water drainers. the w ork involves closing/blanking of valves, st eam purging of pipe/drain pot and opening of f langes of seal pot and removal of muck/deposit from pots, revisioning of gas inspection valve,w ater filling valves,condensate valves. fixing of new packing and tightening of f langes. filling of w ater in the seal pot and de-blanking of w ater drainer/opening of valves. checking for any leakages and rectification of the same " , the job involves cutting/dismantling of corroded structures like column, platforms, w alkw ays, staircases etc. at height. before cutting of any structure, the nearby pipe lines or any other equipment to be supported f irst. the dismantled structures should not be throw n from height. all the dismantled structure to be kept at one place as directed by o.a.s representative for disposal by bsp , the job involves fabrication of st eel structures like column, platforms, w alkw ays, staircases etc. by type 1 electrode, as per approved draw ing / specification or as directed by oa/oa¿s representative complete in all respect including painting. fabricated structures w ill have to be erected by the contractor at height as per the direction of operating authority , the job involves w elding of tack w elded pipes, gland compensators, disc compensators, flanges, st eel structures, gas pipeline equipment, plates, pipes, structures w ith type 1 w elding electrodes , dismantling of gas pipe line or any other pipe line by cutting, including handling and stacking, cutting into pieces and sections as directed by oa/oa¿s representative & stacking at designated location. before cutting the nearby pipe lines/platforms/equipment to be supported. all dismantled structural items to be kept at a particular place, as show n by o.a.s representative for disposal by bsp , job involves erection of fabricated/available pipes at locations show n by o.a./o. a' s representative, including dia. 100mm at heights. erection job involves, lifting of standard length of pipes supplied by bsp free of cost, w elding w ith the existing pipes/valve f langes and testing of pipe w ith st eam/nit rogen and defect rectification w ith type i electrode. any accessories like bleeder pipe, drainer pipe, purging nipples, valves,compensators, saddle supports etc. also to be erected, as directed by o.a , fabricated/available pipes at locations show n by o.a./o.a. s representative, above dia. 100mm and up to dia. 200mm at heights. erection job involves, lifting of standard length of pipes supplied by bsp free of cost, w elding w ith the existing pipes/valve f langes and testing of pipe w ith st eam/nit rogen and defect rectification w ith type i electrode. , fabricated/available pipes at locations show n by o.a./o.a. s representative, above dia. 200mm and up to dia. 500mm at heights. erection job involves, lifting of standard length of pipes supplied by bsp free of cost, w elding w ith the existing pipes/valve f langes and testing of pipe w ith st eam/nit rogen and defect rectification w ith type i electrode. any accessories like bleeder pipe, drainer pipe, purging nipples, valves, compensators, saddle supports etc.also to be erected, as directed
Tender For supply of 60-62 hp, 3 phase submersible pump energy efficient, 2860 to 3000 rpm, 03/04 stage, discharge: 2016 lpm (max.), head: 70-80 meter, rated current: 85.5 a (max.), efficiency: 58%, outlet: 125 mm, suitable for 6 inch dia 3 mtrs column pipe, with threaded ms flange should have tight in both threaded ends of column pipe, thickness of flange 1/2 inch each ms flange should have 8 nos 5/8 inch dia holes & suitable ms reducer or expander with the pump. make- ksb pumps ltd or similar [ warranty period: 12 months after the date of delivery ]
Tender For repair of trash rack gate of size 3.x 2.1 mtr 1 no., fabrication and erection of m.s. structure for monorail, anticorrosive painting to column pipe etc. at lower terana lis stage 2 arani.