Web Analytics Made Easy - StatCounter

Galvanized Post Shore Tenders

Get complete information related to latest Galvanized Post Shore Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Galvanized Post Shore Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Galvanized Post Shore Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45326916 Due date: 26 Jun, 202626 Jun, 2026 1.16 Crore
Tender For corrigendum : special repair renewal replacment of furniture against exp voucher and conversion of charpoy gi pipe nylon newar to charpoy gi with plywood top under ge n mamun at mamun mil stn

Central Government/Public Sector

CTN :45326868 Due date: 23 Jun, 202623 Jun, 2026 48.13 Lacs
Tender For corrigendum : special repair for replacement of old rusted gi pipe line at chhoti vd and badi vd road at new cantt under ge (west) prayagraj.

State Government

CTN :45543210 Due date: 29 Jun, 202629 Jun, 2026 NA
Tender For supply of materials for maintenance work at 132kv sub station ghatampur under etd-ii kanpur - jaw assembly suitable for 36kv isolator, rating 2000a made of copper strip, aluminium strip, ms housing with spring nut and bolt as per sample., daw assembly suitable for 36kv isolatorrating 1250a made of copper strip, aluminium strip, ms housing with spring nut and bolt as per sample., terminal connector suitable for 36kv ct terminal rod and other end twin zebra conductor. made of lm-6 aluminium alloy with galv. nut & bolts. as per sample., 132kv special type isolator bi-matellic terminal connector (dropper/runthrough type) 50mm dia. and moose conductor as per sample., terminal connector suitable for 36kv ct terminal rod and other end twin panther conductor. made of lm-6 aluminium alloy with galv. nut & bolts. as per sample., terminal connector suitable for 36kv vcb one end terminal plate and other end twin zebra conductor made of aluminium alloy. with galv. nut & bolts. as per sample., terminal connector suitable for 36kv vcb one end terminal plate and other end twin panther conductor made of aluminium alloy. with galv. nut & bolts. as per sample without holes., terminal connector suitable for 36kv rama make isolator jaw plate size 80x80mm & 12mm thick and other twin panther conductor made of lm-6 aluminium alloy with gal. nut & bolts., multipurpose cleaner dc 2-26 spray type 400ml pack of standard make., 400 watt hpsv ballast suitable for high mast light fitting., termminal connector for 132kv pt suitable for panther conductor made of all alloy lm-06 completer with nut-bolt and washer as per sample., indication led ryb (24-110v) ac/dc standerd make suitable for control panle., silica gel 6-12mm granules of blue colour, sealed pack packing., terminal connector suitable for 36kv rama make isolator jaw plate size 80x80mm & 12mm thick and other twin zebra conductor made of lm-6 aluminium alloy with gal. nut & bolts., nut bolt with washer size 10x50 mm (gi), nut bolt with washer size 12x50 mm (gi), nut bolt with washer size 10x65 mm (gi), nut bolt with washer size 12x65 mm (gi), terminal connector lm-06 all. alloy suitable for 132kv ct heptacare make other end twin panther conductor with gi nut & bolt as per sample., terminal connector made of lm-6 alloy suitable for 33 kv g.nandy make solator jaw plate and other end twin panther conductor with galv. nut, bolts & washer as per sample., cb clamp 145 kv suitable for panther conductor with galv. nut & bolts., supply of female contact for 145kv rama make isolator as per sample., supply of male contact for 145kv rama make isolator as per sample.

corporations/Associations/Others

CTN :45502867 Due date: 30 Jun, 202630 Jun, 2026 21.93 Lacs
Tender For material supply for the installation of 4 line hanging solar power fence at perambra estate - hanging solar power fence, p.p reel insulator-must be of virgin plstic material.polypropylene or equivalent with break down voltage of 15 kv(weight 25gm avh, length 4.6 cm avg), strain insulator- must of poly polypropylene plstic rated for 15 kv uv stabilized,(weight 40gm avg, length 7 cm avg), gi post 12 feet-2" gi pipe guage thickness, total 14.5 ft length modified to 12 feet length and cut and welding to 90 degree bend 2.5 feet length at top end and having diametrically opposite holes of size 6mm at end of bend pipe, intermediate post (t angle post)-6ft.,paited(25mmx25mmx3mm)having holes of size 6mm at required interval of fencing installation, supporting post- 10ft., gi-1",14 guage thickness,painted, stay (t angle)-2 ft., painted(25mmx25mmx3mm), 12 swg ht wire-12 guage,25mm dia high tensile with zinc coating for use as conducting wires for binding strain inulator, 14 swg binding wire- high quality zinc coating wire for binding reel insulators,tighing support post with corner post, 1.5 mm stainless steel wire rop 304 grade-1.5 mm stainless steel wire rop 304 grade, aluminium ferruel- aluminium ferrule inner dia 3mm, wire tightner- permanent wire tightner made of special aluminium alloy designed for kv,uv stabilized, earth rod- copper plated earth rod 14mm -3 ft. length, earthing compound- earthing compound 8kg, gate handle- gate handle and spring assembly. handle made of polyethyelene, leadout cable- lead out cable for fencie system double insulated gi cable inner core wire 2 sq.mm. hot dipped galvanlsed steel core, cable of with standing 15 kv should be provided to prevent bimetal salt formation at connections, single core 2.5 mm sq. cable- 2.5 mm2 single core copper cable for connecting the solar panel to the tuber battery through charge control unit with required terminal sockets, nut and bolt, washer, lightining diverter- 15 kv rod gap arrester,must be capable of diverting stray lightining and adjustable for spark raps adequate earthing to be provided, 100 watt solar panel- 100 watt/12 volt and above poly crystalline with 10 year warranty having iec/mnre certification, charge control unit- 20a, 12/24 v pwm charge controller unit of standard make suitable to control the charging of the tubular battery, energizer- energizer with 10 kv output safety standerds to be followed and bis 302-2-76 iec60335-2-76. switch high,medium and low power of settings, fence alarm system- fence alarm system conering area of 1.5 km, solar panel supporting stand with metal box painted ( for battery and energiser)- 18 guage thickness metal box (lockabe). gi sheet, painted should be capable of housing battery, charge controller and energizer and fixed with required clamps and nud and bolt on solar panel support stand made of gl pipe of 50mm daimeter and b class type with suitable arrangement for holding the panel, warning sign- polyethylene plastic with satuatory warning with signs, tubular battery 12v,100ah- 12v, 100 ah c10 rating with full 5 year replacement warranty(tower battery) for energising the energiser

CTN :45535749 Due date: 29 Jun, 202629 Jun, 2026 4.63 Lacs
Tender For providing, laying and jointing 50 and 32 mm dia g.i. pipe with special such as bends, elbows, tees nrb and gate valve at site ward no. 01 kishan bagh to baale mayian ki sahib ki dargah(molik nidhi). file no. 49/26x9/1. 2nd call

Central Government/Public Sector

CTN :45231373 Due date: 20 Jun, 202620 Jun, 2026 29.12 Lacs
Tender For corrigendum : special repair to replacement of old unserviceable gi pipe lines and allied works in eme zone and engr zone area at kpg mil stn under ge 867 ews

Central Government/Public Sector

CTN :45537909 Due date: 03 Jul, 202603 Jul, 2026 38.83 Lacs
Tender For special repair to external gi pipe line of otm and md accn at se falls under ge shillong

Central Government/Public Sector

CTN :45171339 Due date: 18 Jun, 202618 Jun, 2026 37.48 Lacs
Tender For corrigendum : special repair to gi/ ppr water supply distrbution line of certain md accns of north zone mil stn under ge (s) binnaguri

State Government

CTN :45523938 Due date: 19 Jun, 202619 Jun, 2026 23.14 Lacs
Tender For special repair to r/c building known as hanuman prasad, in e-2 division, mumbai. repairs to drainage line and p.v.c, g.i. pipe

Central Government/Public Sector

CTN :45542259 Due date: 29 Jun, 202629 Jun, 2026 43.00 Lacs
Tender For special repairs to building no iv at mh wellington and special repair replacement of gi pipes into di pipes of ava hill and lake view area and certain minor work under ge wellington
 Loading, Please wait...

Connect us via What's Up