Get complete information related to latest Gel Dryer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Gel Dryer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Gel Dryer Tenders.
Tender For supply of drum assembly canon ir 2006n - drum assy of canon ir-2006n , book folders , printed book with laminated paper 300 gm , water bottle , rope navi 10 mm , borosil glass , ice box 5 kg , broom , grass desert cooler , water dispenser , thermos steel 1 ltr , tray , food carrier hot box , mattress
Tender For erection and fabrication work a c c - mill mein lage scraper hetu discharge chute ke jo bhag kamzor evam kat gaye hain. unhe kaatkar hatana tatha nai 12 mm ki plate se taiyar kar punah sthapit karna. sath hi scraper ko baandhne hetu profile ke anusar hole wali plate lagakar/welding karke fix karna evam karya poorn hone ke pashchat trial dena. , cane carrier ke gale/ghise runner base ko kaat kar hatana. 100 mm ke channel se box banakar runner base ko lagana evam fit karna va purane channel ko nikal kar seedha karke palat kar lagana. , cane unloader ke purane ghise/kate 40/50 mm size ke sq. bar ko kaat kar hatana tatha yathasthan poorv ki bhanti naye sq. bar ko lagana evam santoshjanak trial dena. , cane carrier/rake carrier/bagasse elevator/r.b.c. ke ghise/kate runner ko kaatkar hatana. uske sthan par purane ko palat kar athva naye runner ko poorvanusar lagana. , cane carrier/rake carrier/r.b.c. ityadi chains ke side ki kati/ghisi/kamzor plate ko kaatkar hatana. uske sthan par purani athva nai plate ko lagana. , fibrizer hood ki side ki ghisi/kamzor plates ko kaatkar nikalna tatha yathasthan nai plate ko lagakar andar va bahar se welding kar santoshjanak trial dena. , bagasse baling machine ki sampoorn overhauling. testing evam trial dena. , s.r.c./i.r.c. ki purani racks ki vanchhit marammat karna. , bagasse elevator/r.b.c. ki chains ki nai racks sample anusar taiyar karna. , t.r.p.f. ke gale/kamzor bottom/top cover ko badalne ke liye naye cover poorvanusar banakar lagana evam santoshjanak trial dena. , s.r.c./i.r.c. ke gale/kamzor tail end boots ko kaatkar hatana tatha sample anusar 8.0/10.0 mm moti purani/nai plate se taiyar kar lagana evam leak.proof welding kar santoshjanak trial dena. , cane unloaders ke panjon ke vibhinn parts ko dismantle karna. dismantle kiye gaye grabs ke sabhi parts ki vanchhit marammat karna. fingers par nirdeshanusar hardfacing kar panjon ka punah assembly karna. , mills ke compound imbibition hetu lagi juice tray mein se gali/kamzor juice tray ko kaatkar hatana. nai plate se sample anusar taiyar kar yathasthan lagana evam samast connection karna. , cane carrier/s.r.c./i.r.c. tatha bagasse elevator chains ko upar uthne se rokne ke liye lagi hui guides mein se ghisi/kamzor guides ko kaatkar hatana. nirdeshanusar nai guide taiyar kar yathasthan lagakar santoshjanak trial dena. , cane unloaders ke bridge/trolley drive ke ghise/kate wheels ko nirdeshanusar welding karna. , t.r.p.f. ke gale/kamzor donali chutes ko kaatkar hatana tatha purane anusar naye donali chute fabricate kar yathasthan erection karna. , cane carrier ke liye lagi idler wheel par nirdeshanusar m.s. ke ring fabricate kar lagana. , mill head stock evam t.r.p.f. head stock ke beech nirdeshanusar 25.0 mm plate se support banakar lagana. , fibrizer ke purane hammer shanks ko nirdeshanusar welding evam hardfacing kar marammat karna evam balance karna. , cane chopper/leveller ke gale hue/kamzor hoods ko kaatkar hatana tatha nai plate se naya folding type banakar lagana. , fibrizer ke pocketed type anvil plate ki pockets ki tooti plates ko nai plates se badalna. mudi hui plates ko seedha karna tatha welding kar taiyar karke nirdeshanusar hardfacing karna. , cane leveller/chopper ke rotor assembly ki ghisi hubbo ke working side evam top sides ko welding kar samatal karna evam nirdeshanusar hardfacing karna. , cane unloaders par lage reduction gear evam motors ke kamzor beds ko kaatkar naye modify karke naye bed banakar lagana tatha gear evam motor ka alignment kar trial dena. , cane carrier ki structure ke gale/kamzor columns ko nirdeshanusar plate lagakar welding kar majbooti pradan karna. , mill rollers mein sample anusar juice ring fabricate kar fit karna. , t.r.p.f. evam mill ke beech mein lage pressure chutes ki vanchhit marammat karna. , mills ke gale/kamzor juice receiving tank ko kaatkar hatana. 8.0/10.0 mm moti plate se sample anusar tank fabricate kar yathasthan fit karna evam samast connection kar leak.proof trial dena. , mill ke ju
Tender For corrigendum : supply of 2.5 inch, 5tb internal hard drive , hard drive carrier tray (caddy) for 2.5-inch sata ssd/hard disk , 3.5 inch, 8tb internal hard drive , hard drive carrier tray (caddy) for 3.5 inch sata hard disk
Tender For corrigendum : rate contract for medicine - stainless steel abdominal hysterectomy set, n.s.v set (s.s), g.v set, self abdominal detractor, m.t.p set., vaccine carrier (small size), x-ray digitalisation with high-end cr system (with installation & 1 yers. warrenty) console software with mulitmodality work station the cr system should have advances workstation provided with 17" high resolution monitor, keyboard & ouse, with the fol., digital ultrasound machine colour dopler (high resolution ) with 4 probe, semi auto analyzer, fully automated bio-chemistry analyzertechnical specificationsthroughput-150t/hr (constant with both mono and double reagent)system function-random access/stat/batchtest method-end point, fix time, kinetic, (single/double reagents chemistry, mono/ bio-chromatic measurements)calculation methods-1 point linear, 2 point linear, exponential, logit log3p, logit log 4 p, logit log 5p, spline, line graph, k factorblank-reagent blank, sample blank, pre sample blank, pre reagent blanksample tray-40 position, sample volume :2-30 ui, 0.1 ul increment, micro cup, & test tube can be used for samplereagent tray-80 position, reagent volume: 20-300 ul, 1 ul incrementmixing system-teflon coated mixersample probe-1 needle with liquid detector, shock sensoroptics-halogen-tungsten lamp, absorbance range: 0-4.0 abs resolution: 0.0001 abs.diffraction photometry with wave length: 340, 405, 450, 505, 546, 578, 630, 700nm & 4 more optionswash station-12 step washing, 4 needle wash station, 1 dry pad, external needle cleaningcalibration-linear and non-linearqc-multi-level qc setup with levy-jennings graph and westgrads multi rules with mean sd, and cvwater consumption-not more than 6l/hrtemperature-reagent: 2-14 c (24 hr refrigeration), reaction cuvette: 37c 0.1 humidity- 80%system interface-usbpower requirement-ac 220v 10%, 50/60 hzdimensions-750 mm*560mm*530mm, hotair oven, binocular microscope (olampus), centri fuge machin (good quality), micropipette (0-50 microliter), micropipette (0-500 microliter), micropipette (0-1000 microliter), microtips (0-50 microliter), microtips (0-1000 microliter), bed side screen with cloth 1"round pipe with wheel, sponge holding (all size), artery forceps 6" curved, artery forceps 6" straight., artery forceps 8" curved, artery forceps 8" straight., artery forceps 4" straight., alliys tissue forcep (all size curved straight), mosquito forcep (all size curved straight), scissor 6 " curved (all size), scissor 6 " straight (all size), scissor mosquito straight. (all size curved, straight), diatheromy (machine), laparoscopic instrument full set (best quality), needle holder 8 "curved, needle holder 8 " straight, needle holder 6 "curved, needle holder 6 " straight, needle holder 4 "curved, needle holder 4 " straight, doner couch (3 motor), blood weighting mechine, blood band refrigerator (300 bag) temp.display outside, elisa reader with washer mechine with printer & ups., doner couch (3 motor), blood weighting mechine, blood band refrigerator (300 bag) temp.display outside ( best quality), fully automated chemiluminescence analyzer(clia) 1. system should be fully automated walk -away with continuous loading facility.2. analyzer should have able to perform thyroid, bone, cardiac, fertility, diabetes and anemia profile test.3. working principle of system should be micron super paramagnetic particles platform with alp labeled reagents and amppd substrate.4. must have 3 phase magnetic separation with precisely controlled temperature.5. analyzer should have photon counting detection mode with photomultiplier photo counter with led reference module.6. the analyzer must have vortex non-touch mixing which can reduce carryover., 7. throughput of the system should be more than 180 tests in a hour.8. system should have 15 reagents onboard with onboard 2 -8 nonstop refrigeration facility 9. system should have at least 50 sample positions and continuous loading facility.10. system should have cont
Tender For supply of sized ii medium sized fine tipped iii fine plain 4 each , forceps dissecting forcep adson heavy medium sized medium sized fine tipped fine tipped four each , forceps dissecting plain 12 pt 5 cm , forceps dissecting plain 18 cm , forceps dissecting toothed 12 pt 5 cm , forceps dissecting toothed 18 cm , forceps nasal dressing , forceps ovum heywood smith 25 cm , forceps sinus 18 cm , forceps sterilizer cheatle , forceps tongue , foreign body forceps hooks , gall stone holding forceps , hartman tuning fork , health aural forceps , heany hystectomy forceps 20 cms st and curved , kelly curved on flate box joint 14 cms haemostatic forceps , kidney tray ss 10 inch , kidney tray ss 8 inch , knife bard parker handle no 3 , knife bard parker handle no 4 , kochars intestinal forceps , kochar s intestinal forceps curved on flat 23 pt 8 cm , mayes curved in flat 16 pt 5 cms scissors , mayo artery forceps on pin , mayo peen curved on flat box joint 16 pt 3 cms haemostatic forceps , mcindoe scissors , metzenbaum scissors straight and curved , mosquito artery forceps curved , nasal dressing forceps , needle cutting and non cutting for suture tray , needle holder 19 cm , needle holder for suture tray , right angle mixter forceps long , right angle mixter forceps medium , right angled forceps laheys , scissor curved on flat mayo 19 cm , scissors counter 18 cm , scissors dressing straight both point blunt 12 pt 5 cm , scissors dressing straight both point sharp 12 pt 5 cm , scissors straight mayo 19 cm , speculum nasal second largest , splint knee thomas collapsible 25 inch , stand transfusion metal iv stand , steriliser electric for surg instrument 430 mm into 150 mm internal ac 230 volts 2000 watts complete , steriliser steam high pressure drum shallow for size 28 pt 5 cm into 12 cm , sterization drums , surgeon hydraulic chair , suture scissor for suture tray , suture tray , syringe enema higginson , table dressing , tilleys forceps , tissue cutting scissor , torch light , tray ss 10 inch into 8 inch with lid , tray ss kidney shaped 25 cm , tray ss shallow size 27 pt 5 cm into 22 pt 5 cm , tray ss shallow size 35 cm into 30 cm , tray with wrapper for suture tray , tuning fork , umbilical cord scissors , vaccine carrier , vascular forceps angular , vascular forceps straight , weighing machine