Tender For corrigendum : supply of hrc fuse, tubular type, 2 amp, 1.2 kv, size : 8x50mm (gg) suitable for use in power panel (ht side) of lhb variant eog coaches as per drawing no. pcee/gs/2amp fuse/02 and confirming to rdso modification letter no. el/7.1.108/sbc dtd. 16.10.2018. accepted make: similar to category no. 184000.2 of siba / hvw-ir (2 amp) of bussmann (eaton)/ wohner/ferraz. [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : supply of fuse base for tubular type hrc fuse, 2 amp, 1.2 kv ac as per drawing no. pcee/gs/2 amp fuse/02 suitable for use in power panel (ht side) of lhb variant eog coaches. accepted make: siba/wohner/ferraz/ eaton bussman. [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : design, manufacturing, supply, installation, testing and commissioning of ht capacitor bank with apfc panel at ferro chrome plant, omc.
Tender For providing 11kv ht cable to the substation, 11kv ht rmu panel and fencing at nium, kottigepalya, bangalore. sh. providing of ups wiring distribution to skin department & miscellaneous at nium, kottigepalya, bangalore
Tender For maintenance of electrical installation & fans, sub-station, diesel generator set at old & new cgo complex, nh-iv, faridabad.subwork/packages:servicing of lt/ht panel, transformer and other allied equipments at sub station cgo complex nh-iv, faridabad.
Tender For e- nit no. micd 15 of 2026-27 dated 20-04-2026servicing / routine maintenance of various electrical gadgets like ht/lt motors of high lift/ low lift, lrs, f.a.s.d. starters, ht panels, lt panel and overhead travelling electric crane at rafiabad lift
Tender For supply of electrical testings - testing of earth pit , testing of relay , thermography of htlt panels , making single line diagramlaminated,past , preparation of earth pit layout , insulation mat testing , battery load tester , transformer oil testing test report , testing of transformer tan delta , testing of transformer partial discharge , routine testing of transformer , routine testing of 11 kv vcb , oti calibration , wti calibration , testing of third harmonic la , test checking vcb bottlehealthiness , vlf testing of cable , testing insulation resistance , electrical safety audit external , calibration of ammetervoltmeter , replacement of ammetervoltmeter , calibration of energy meter , replacement of energymeter , routine testing of acb , partial disch testing of cable ht and lt , testing for ht cable tan delta , type-2 coordination study , arc flash study of ht panel , des spl 11 kv h pole structure
Tender For supply of breakers - 11 kv ct swbd. incomer-breaker retrofit , 11 kv ct swbd. motor feeder retrofit , 11 kv ct swbd. trafo. feeder retrofit , 11 kv ct swbd. seht feeder retrofit , 11 kv ct swbd. bus-pt panel retrofit , installation testing commissioning of switchgear components for refurbishment of abb make 11 kv switchbaord at coastal terminal ht substation including retrofitting of existing sf6 circuit breakers with new vacuum circuit breakers vcbs panelcontrol wiring modifications for numerical relay retrofit and conversion to 110 vdc auxiliary supply as per tender specifications scope of works and directions of engineerincharge