Get complete information related to latest Generator Panel Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Generator Panel Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Generator Panel Tenders.
Tender For supply of electrically operated lifting barrier with hand generator each set consisting of 2 no s. of lifting barrier pedestals, each with 8 contact circuit controller with top roller type limit seitches (as per design given in specification & approved by rdso) hand crank, electric motor 110v dc, 2 gi sheet booms of 32 ft length (4 section of 8 ft long each) with new octagonal shape as per rdso approved drg. no. rds o/s-11600 without fringes, with 2 stop boards and boom light boxes, ms counter weights and 02 nos. of bo om supports with motorized/ solenoid boom locking along with 01 no. of hand generator cum control panel to operate 2 barries of a set with 1 selector switch, 3 buttons and 5 indicating lamps, contractors mcb's an d relays as per rdso spec no rdso/spn/208/2012 or latest. [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : repairs/ day to day maint of street lights/solar street light/ pole/ cable junction boxes/ timer switches/ search lights rusted steel poles alongwith repairs/ day to day maint of standby dg set/ amf panel/control panels /cable/dg set earthing at darj
Tender For supply of fire bucket,water co2 extinguisher 9ltr,dry chemical powder extinguisher 5kg,dry chemical powder extinguisher 10kg,co2 extinguisher 4.5 kg,co2 extinguisher 2.5 kg,abc extinguisher 5 kg,abc extinguisher 2 kg,abc extinguisher 1 kg,hydrant valves,mains,hose pipe,branch pipe nozzles,hose boxes double door,hose reel,main pump and motor,diesel pump,fire jockey pump,suction and delivery valves of pump,sprinkler 68 degree,manual call point,hooter,smoke detector,twenty zone wise control panel,fire alert hot line security system,fire pipes,comprehensive annual maintenance of existing firefighting system
Tender For repair / maint of mcb / db, submain wiring, earthing, control panel, meter boxes in certain md accn and otm accns at af-i under ge (af) jamnagar no.2
Tender For corrigendum : custom bid for services - repair and maintenance of ac modules dc modules and various pcbs of all departmental drilling rigs of ongc tripura asset-work includes but not limited to supply of men, materials, testing equipment / tools etc for fault finding (trouble shooting), repairing, calibration and functional testing of ac modules, dc modules and various pcbs in e1400 series drilling rigs of tripura asset. broad details of the activities to be carried out are as below: a. following jobs are to be carried out in pcbs i. physical checking of healthiness of components & cleaning of the pcbs. ii. checking of voltages at different points in the pcbs after powered up through simulator. iii. replacement of faulty components, limited to 50% cost of the pcb, to make it operational. iv. calibration of pcbs v. on load testing of 12 hrs. continuous loading for satisfactory operational vi. fixing of pcbs in the respective panels b. following jobs are to be carried out in ac module i. visual inspection of module for any loose hardware & cleaning of the module. ii. checking of circuit by using simulator. iii. checking of over frequency tripping. iv. checking of under frequency level. v. under frequency voltage cut back test vi. idle-run ramp and idle trip test vii. throttle regulation check viii. master slave and command circuits check ix. current demodulator check x. automatic voltage regulator check xi. meter circuit check xii. over voltage trip check xiii. reverse power trip check xiv. frequency demodulator check xv. module panel meter check xvi. replacement of faulty components, limited to 50% cost of the ac module, to make it operational. xvii. on load testing of 12 hrs. continuous loading for satisfactory operational xviii. fixing of ac modules in the generatorpanel c. following jobs are to be carried out in dc-module i. visual inspection of module for any loose hardware & cleaning of the module. ii. dead band and current limit calibrations iii. zero throttle interlock circuit test iv. firing circuit test v. speed feedback circuit test vi. power limit circuit test vii. slave circuit test viii. manual voltage circuit test ix. over current trip calibration test x. meter circuit check xi. replacement of faulty components, limited to 50% cost of the dc module, to make it operational. xii. on load testing of 12 hrs. continuous loading for satisfactory operational xiii. fixing of dc modules in the dcpcr panel d. following jobs are to be carried out in battery charger i. visual inspection and cleaning of components such as transformer, voltmeter, ammeter, pcbs, rectifier, indication lamps and tightening of loose hardware, if any. ii. checking of tripping logics, dc under voltage, dc over voltage, reverse polarity, ac mains fail, over current, over temperature etc. iii. replacement of faulty components, limited to 50% cost of the battery charger, to make it operational.-msme exemption - no | startup exemption - no
Tender For operation and maintenance of led street lighting and centralised control monitoring sysytem (ccms) boxes for a period of two (02) months in yelamanchili municipality under municipal general fund.
Tender For s/i of additional safety items for krishi radio station at main campus shalimar, skuast-k.(capex) - fire detection & alarm system, supplying, installation, testing & commissioning sector control panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per is:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required., 4 zone, supplying, installation, testing & commissioning of heat detector each operating at 54 c/57 c with rate of rise cum fixed tempreature (dual thermistor) type with mounting base complete with all connection etc. as required., supplying, installation, testing & commissioning of smoke detector each with builtin led and mounting base complete with all connections etc. as required., supplying, installation, testing & commissioning of manual call each boxes of ms construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as recuired, supplying, installation, testing & commissioning response indicator each on surface/recess ms box having two leds metallic cover complete with all connections etc. as required., supplying, installation, testing & commissioning fire alarm sounder each with facility to make announcement, mounted in a.b.s. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required., supplying, installation, testing & commissioning talk back slave station in surface/recess suitable for operation on simplex mode complete with p.t.t. knob & speaker/microphone enclosed in a m.s.(16 swg)/ abs box with break glass in front etc. complete as required., supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000v rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of cross linkable ethylene propylene rubber (epr) insulation and lszh inner bedding, steel wire armouring & lszh outer sheath complete as required., supplying and fixing of co2 type fire extinguisher isi marked confirming to is: 15683 capacity 4.5 kg complete with delivery hose horn, squeeze grip release valve , locking arrangement, operation manual, bracket with two screw and sleeve including transportation cartage upto various post in kashmir region of sib as per anexure attached etc complete as required. (make : life guard/minimax/safeguard), providing and fixing abc type (dry power type ) extinguisher as per is: 15683 consisting of welded ms cylindrical body, with discharge hose, discharge valve, suspension bracket, initial filling, pressure gauge including transportation cartage upto various post in kashmir region of sib as per anexureattached.etc complete as required. (make : life guard/minimax/safeguard), capacity 6 kg., fabrication, supply, installation, testing & commissioning of indoor type compartmentalized feeder pillar having front area not less than 0.60 sqmtr (900 mm x 900 mm) and depth 45 cm (ns) made out of 2mm thick crca sheet with tappered roof having separate cable and bus bar alley, 1 door arrangement i/c locking arrangement, having 400 amp four pole aluminium bus bar of full length with base frame made out of 50mmx50mmx6mm (thick) angle iron having 80cm legs for erection in ground with construction of cement concrete suitable foundation size complete with connections and interconnections with copper conductor pvc insulated cables/ insulated aluminium busbar strips of appropriate size and terminal blocks (on outgoing) including supplying & fixing following switchgears & accessories there in, powder coating, labelling, earthing etc. complete as required. providing and fixing following accessories in existing cubical panel board i/c making connection etc. as reqd.details as under panel powder coated 2.0mm mccb 160 a 4p 50ka , ther
Tender For procurement of helo starting rectifier and associated sub assemblies for fss - transformer - rectifier 28.5 plus or minus 0.5v dc, 17kw, 600a , dc contactor box , dc flight deck socket box fitted with one socket of suitable rating , dc hanger socket box having two sockets of suitable rating , socket box water tight for remote positive sensing , start or service switch in watertight housing , power panel with mcb type 126c 60a , power panel with mcb type 113c 30a , power panel with mcb type 115c 40a , bench power outlet box , dc switch socket 15 amps , connection box 3 way , connection box 4 way , dc flexible cable assemblies along with suitable nato plug or adapter for starting and servicing , a suitable capacity portable rechargeable 28v dc power source along with adequate length of charging cables, connectors and adapters suitable , cable reel drum for stowage of dc flexible cable assembly , ac contactor box , ac control box , ac overload box , ac flight deck socket box 6 pole, 200v, 400hz, 3phase, 4wire water tight complete with matching plug , ac hanger socket box , power panel for helo starting and servicing supplies 200v, 400hz, 3phase, 4wire , power panel for helo starting and servicing supplies 115v, 400hz, 1phase , switch sockets 200v, 400hz, 3phase, 5amps with matching plug , ac junction boxes , ac flexible cable assemblies along with suitable nato plug or adapter for starting , ac flexible cable assemblies along with suitable nato plug or adapter for servicing , cable reel drums for stowage of ac flexible cable assemblies 01 each for starting and servicing cable , cable entry glands, gland plates, shock mounts as required , technical documentation or manuals 09 sets for 1st ship and 05 sets each for balance 4 ships , training , on board spares , service support design, stw, commissioning and trials
Tender For sitc of various essential equipments for the use of various municipal maternity homes - 200/250 amp. 415v tpn switchfuse unit with crca sheet steel powder coated enclosure with hrc fuses & switch links and padlockable arrangement., cable end boxes 200/250 amp. tpn switch fuse, 200 amp. 415v fp on load changeover switch with crca sheet steel powder coated enclosure., supply, installation, testing and commissioning of 50kva dg set comprising of cpcb iv mech, built in amf panel, 1500 rpm, 4 stroke, 3 cylinder inline type, water cooled with radiator diesel, 1st category al armoured cables frls outer sheathed- 3.5c x 95 sq.mm, cable end termination for aluminium cables 3.5c x 95 sq.mm, 3 noss. single core cu pvc insulated flexible cable of 50 sq.mm. for phases & 1 single core cu pvc insulated flexible cable for neutral of 25 sq.mm for 100/125 amp. tpnss switch., cement concrete foundation using m-20 cement concrete mix with j shaped foundation bolts where required, supply & laying of double wall corrugated ( dwc) pipe 125 mm od / 109 mm i.d., concrate excavating the trenches and refilling the same after the cable is laid in approved manner (size of trench: 750 mm deep, 600 mm wide) in concrete/ masonary / asphalt. 1 cu. mtr. = 2.2 rmt., soil excavating the trenches and refilling,reinstatement of the same after the cable is laid in approved manner (750 mm deep, 600 mm wide),in all types of soils 1 cu. mtr. = 2.2 rmt., providing, detailing, composite fabricating members like trusses, ngirders,girders, bracings, supports, purlins, runners, and similar structural steel members fabricated using m.s. hollow tubular steel, bare galvalume/zincalume sheets for roofing, earthing station with 600 mm x 600 mm x 6 mm galvanised iron plate, 25 x 3mm gi, bare g. i. conductor size 10 swg., removal of switchgears/ dbs upto 200 amp., removal of switchgears/ dbs above 200 amp to 400 amp., removal of busbar chamber above 100 amp tpn to 800 amp tpn., removal of cable above 3-1/2 core x 35 sq. mm. to 3-1/2 core x 70 sq. mm, removal of cable from 1.5 sq.mm to 3-1/2 core x 35 sq.mm., refixing of 2 core/ 3 core/ 3-1/2 core / 4 core/ 6 core copper / aluminium conductor armoured / unarmoured cable 1.5 sq.mm. to 16 sq.mm. size on wall / ceiling etc., refixing of 2 core / 3 core / 3-1/2 core / 4 core/ 6 core copper / aluminium conductor armoured / unarmoured cable above 16 sq.mm. to 150 sq.mm. size on wall / ceiling etc., 415v main distribution panel 1 short circuit reating 50ka for 1 sec. 400a (thermal magnetic overload, short circuit release) mccb with rotary operating mechanism as incomer with digital ammeter,, 200a 4p mccb, 100a tpn mccb, 3 noss. single core cu pvc insulated flexible cable of 95 sq.mm. for phases & 1 single core cu pvc insulated flexible cable for neutral of 50 sq.mm for 200 amp tpnss switch., g.i. cable tray with all other accessories 150 x 25mm (w x h) - (16 swg - 1.6mm) without cover, cable end termination for aluminium cables 3.5c x 50 sq.mm, cable end termination for aluminium cables 3.5c x 120 sq.mm, cable end termination for aluminium cables 3.5c x 70 sq.mm, cable end termination for aluminium cables 3.5c x 50 sq.mm, 20w led flood light luminaire ip65, 1st category al armoured cables frls outer sheathed- 2c x 6.0 sq.mm, gun metal gate valves (screwed):-50 mm dia., gun metal non - return valve: (screwed):-50 mm dia., gun metal gate valves (screwed):-15 mm dia., gun metal foot valve 50 mm dia., automatic pump control panel, hose oil cooler to water pump, worm drive hose, fuel supply pipe, injector overflow pipe (return pipe), hose for oil cooler inlet, hose clip thermostat, vent hose (epdm) for gens, ax-45-cogged belt, hose water manifold to ther, dse 6120/ 4520 controller, battery exide 12v 110ah, oil filter 4 cyl -, fuel filter 4 cyl -, air filter element outer 4 cly m&m, centrifugal oil filter 4c, radiator aluminium, radiator exhaust fan, radiator core, charging alternator, alternator winding main, alternator ar