Web Analytics Made Easy - StatCounter

Geochemical Survey Tenders

Get complete information related to latest Geochemical Survey Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Geochemical Survey Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Geochemical Survey Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :38465433 Due date: 04 Jan, 202504 Jan, 2025 92.81 Crore
Tender For design, engineering, manufacturing, quality surveillance, testing at manufactures works, packing, supply, delivery f.o.r bidadi site, erection, testing, commissioning and conducting performance guarantee tests for 26.5mwp /20 mwac ground mounted solar project at bidadi, ramanagara dist 562109 with all civil, structural, mechanical, electrical works, insurance towards transit risk storage intra site transportation with all civil, structural, mechanical, electrical, control instrumentation works including five years of comprehensive operation and maintenance, on the basis of single point responsibility, completely covering the activities and services in respect of all the equipment works specified and covered under the specifications

CTN :38526292 Due date: 08 Jan, 202508 Jan, 2025 39.38 Crore
Tender For segregation of 11 kv mixed feeders at tonk circles of jaipur discom of rajasthan state under revamped reforms-based and results linked distribution sector scheme (rdss) on turnkey basis against tn-583 - pcc poles, pcc pole 9 mtrs long (400 kg), pcc pole 9 mtrs long (200 kg), outdoor 11 kv o/d vcb kiosk complete with accessories including use of special tools, armoured cable of size 2c x 4 sq.mm. 1100 volts pvc insulated including supplyof ferrules, control cable of size 12c x 2.5 sq.mm. 1100 volts pvc insulated including supply of ferrules, overhead steel cored aluminum acsr dog[100sqmm(6+7) /(4.72+1.57)] conductor complete in all respect as per latest specification and drawing, overhead steel cored aluminum acsr rabbit conductor in all respect, earthing rod sets for s/s made with ms rod (galvanized ) 20 mm dia, 3 meter length with gi wire and clamp as per latest specification and drawing adopted & approved by nigam., ctpt structure set (galvanized), 11kv ct pt set(200/5 amp.), mip meter box for meter with ttb, go double break without eb isolator on existing bracket complete in all respect as required including hardware, nut, bolts & washer etc., 11kv ( with 9 x 24 kv post insulator ) 400 amp., horn gap sets on existing brackets in all respect as required including hardware nut & bolt & washer etc., 11kv ( with 6 x 24 kv post insulator ) 1 set=3 nos, supply of insulators, 11kv porcelain disc.insulators b&s type 45kn, hardware for 11kv disc insulator b&s type 45kn, composite polymer insulators, 11kv polymer disc.insulators t&c type 45kn, hardware for 11kv disc insulator t&c type 45kn, 11 kv composite polymer pin insulator complete in all respect, pg clamps for suitable acsr dog conductor, pg clamps for suitable acsr rabbit conductor, 11 kv danger plate of size 200 x 250 mm complete in all respect, supply of angle and channel, m.s channel 100x50x6 mm, m.s channel 75x40x6 mm, m.s. flat 50 x 6 mm (galvanized), 1.4 mtr channel bracket with clamp, supply of lightening arrestors, substation type 9kv, 10ka station class (1set=3 nos.) lightening arrestors., 11kv double pole line structure set for cut point complete on existing poles in all respect with clamp, as required made from m.s.channel 100 x 50 x ismc ( 9.56 kg. per mtr.) isa m.s.angle 65 x 65 x 6 mm, m.s.angle 50 x 50 x 6 mm and m.s.flat 50 x 6 mm (galvanized as per is), gi stay set (galvanized) complete (stay rod 16 mm dia,1.8 m long,anchor plate 300x300x4 mm,12 mm dia turn buckle) including stay clamps,, strain/guy insulator for stay set, 7/10 swg gi stay wire, gi wire 8swg, underground cable for working voltage of 11kv aluminium conductor (is 7098) cable xlpe armoured, under ground cable of size 3x185 sq.mm for 11 kv, g.i. pipe of 125 mm diameter, b-class (is:1239 mark), gi pipe for cable support at pole ( each 3.3 mtr ), cable for11 kv aluminum conductor xlpe armoured ht cable, xlpe 3x185 sq.mm h.s. on indoor type, xlpe 3x185 sq.mm h.s. on outdoor type, xlpe 3x185 sq.mm h.s.s.t. joint, 11.4 mtr. long lattice tower made of 50 x 50 x 6 mm m.s. angle with 50 x 6 mm m.s. flat for bracing as per nigam specification, 11kv cross arm with top hamper with clamps made of ms angle 65x65x6mm, clamp 50x6 mm, earth clamp 50x6 mm (galvanized), fixing of 11/0.4 kv substation structure set for three phase 63 kva transformer on double poles in all respect. weight (as per specification and drawing with go channel) approx=219.54 kg (all galvanized as per relevant is), 11 /0.4 kv al wound, three phase distribution transformer (completely self protected with provision of lt bushing box), 25 kva, 63 kva, 6.35/0.24kv s/s structure set for single phase transformer on single 9mtr, 400kg pcc pole in all respects., 11kv 100 amp drop out cum isolator with 3.0 amp. fuse & 12 kv post insulators., lt xlpe cable, size 4cx70 sq. mm, size 4cx120 sq. mm, aerial bunched cable, aerial bunched cable 3cx25+1x25 sqmm, aerial bunched cable 3cx50+1x35 sqmm, lt distribution pillar

Central Government/Public Sector

CTN :38456951 Due date: 26 Dec, 202426 Dec, 2024 25.00 Lacs
Tender For repair/replacement of lt ug cable, lt poles, control panels board, change over switches and allied items at af station naliya under ge(af) naliya - taking out old unserviceable lt cable of any size any type from trench/duct/ poles / roof/pipe etc and keeping aside for segregation of serviceability. serviceable cable will be re-laid at same place or other place as required complete all as specified and directed., supply, laying and connecting xlpe insulated, armoured, heavy duty electric cable multi stranded aluminum conductors, 1100v grade, of size 06 sqmm 2core with proper size of lugs and laid in trenches / ducts / through gi pipe / fixed to poles etc complete all as specified and directed. note: excavation earthwork, cable covers, sand cushioning and gi protection pipe shall be measured and paid separately under relevant item., all as per serial item number 2.00 here-in-before but of size 16 sqmm 4 core., all as per serial item number 2.00 here-in-before but of size 35 sqmm 3.5 core, all as per serial item number 2.00 here-in-before but of size 50 sqmm 3.5 core, all as per serial item number 2.00 here-in-before but of size 70 sqmm 3.5 core, all as per serial item number 2.00 here-in-before but of size 95 sqmm 3.5 core, re-laying of old serviceable cable of any size obtained from item above. note:- excavation earthwork, cable covers, sand cushioning and gi protection pipe shall be measured and paid separately under relevant item., excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth and getting out in soft/ loose soil, for laying of under ground electric cable, pipes etc complete all as specified and directed. note:-(i) authorised width & depth shall only be excavated, measured and paid as specified in clause 3.2.3 of ssr part ii and 19.74.1 of ssr part i for cable/pipe laying portion.(ii) serviceable pcc /rcc cable cover obtained during excavation shall be stacked separately carefully without any extra cost to the deptt., material and labour for river bed sand filling in trenches/ ducts 15 cm above cable and 8 cm under the cable for cushioning/protection to cable including spreading, leveling and get thick 18cm after hand punning complete all as specified and directed, laying only serviceable un-reinforced precast concrete cable cover class lv, type 1, flat, of 250 mm x 150 mm x 40 mm obtained from trenches, abetting each other with gap between adjacent slab not exceeding 10 mm over under cable for protection complete all as specified and as directed., supply and laying un-reinforced precast concrete cable cover, class lv, type 1, flat, size 250 mm x 150 mm x 40 mm abetting each other with gap between adjacent slab not exceeding 10mm over under cable for protection complete all as specified and as directed., returning, filling in, including spreading, leveling, watering and well ramming in layer not exceeding 25cm thick each complete all as specified and directed., removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified and directed., material and labour for cutting under the road /pavement /hard standing or in any other situation with the manual labour for crossing of u/g cable through it and making both the end good complete all as specified and directed ., supply and laying gi water tubing of 80 mm bore, light grade, is-1239 marked with all fittings is marked and laid in trenches/under roads/in drains with suitable size flat iron/gi clamps, bolts, nuts and washers etc for cable protection complete all as specified and directed., supply and laying gi water tubing of 50 mm bore, light grade, is-1239 marked with all fittings is marked and laid in trenches under roads/in drains, fixed to poles/walls with suitable size flat iron/gi clamps, bolts, nuts and washers etc for cable protection, complete all as specified and directed ., supply and laying gi water tubing of
 Loading, Please wait...

Connect us via What's Up