Tender For providing of calibration services - medical; medical device calibration; nabl labs, any other government approved labs / service provider; buyer premises (onsite)
Tender For supply of digital pensky martens closed cup apparatus for measurement of flash point a nd fire point as per is:1448 electrically heated with fhp stirrer and digi.... digital pensky ma rtens closed cup apparatus for measurement of flash point and fire point as per is:1448 ele ctrically heated with fhp stirrer and digital temperature controller with two years warr anty and calibration certificate traceable to nabl. equipment to be suitable for operation on 220 v ac single phase. 50 hz. make-globolytics or equivalent.. firms accepted offer: rap-128 digital pensky martens flash point apparatus elect. digital temp. indicator and regulator constant speed stirring device geared motor stirrer oil test jet. [ warranty period: 30 months after the date of delivery ]
Tender For digital wheel diameter gauge fitted with digital dial indicator, specification:-range 800 to 1100 mm accuracy through ver nier scale0.1 mm, dial indicator accuracy 0.01mm dial indicator range 12 mm. gauge should be suitable to measure wheel dia in open an d in fitted condition for all type of railway coaches and wagon. fitted with spring loaded dial indicator plunger with locking device, supply in suitable carry box. with 01 year calibration certificate from nabl approved lab. make:- aoge / pie /ganapathy. [ warranty perio d: 30 months after the date of delivery ]
Tender For supply of electronic toe load measuring device (etlmd)no.tm/sm/etlmd/218 (fourth revision-2022), offensive extended warranty of machine & calibration charges for 18 months (after standard warranty of 1 2 months) as per attached specification. make- pujara engineers or similar [ warranty period: 30 months after the date of delivery ]
Tender For supply & installation of water proof-ph meter for bio-toilet lab with technical specifications of 1 iso 9001 -2008 certified auto deluxe ph meter with automatic temperature compensation. 2. includes a combination ph electro de and rtd probe, with a large lcd display. 3. should be useful for ph and redox potential measurements. 4. measurin g range from 0.00 to 14.00. 5. the device should support touch button calibration and should come with a rotational ele ctrode stand. 6. the device must include 3-point calibration along with calibration certificate. [ warranty period: 30 m onths after the date of delivery ]
Tender For providing of calibration services - load testing of pod handing device; load testing of pod handing device; load testing of pod handing device; load testing of pod handing device