Get complete information related to latest Gis Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Gis Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Gis Tenders.
Tender For repair and maint of 33 kv ahr and r grid including 33 kv gis and 11 kv ais panel repair and maint of 8/10 mva power transformer 11 kv rmus and connected items under age elect supply (sldc) under ge (u) elect supply delhi cantt-10
Tender For construction of 132/33 kv, 2x50 mva gis substation at hathi bhata (ajmer) alongwith associated transmission lines including survey, supply of all equipment/mate rials, erection (including civil works), testing and commissioning.
Tender For survey work with dgps and gis mapping of demjok village preparation of site contour plan for development of model village plan and other necessary features
Tender For rate contract for supply of copper items ( 7 types) - rate contract for supply of copper items (14 types) for gis breaker application for 24 months from approval at bhel, bhopal. evaluation shall be doen itemwise. reverse auction applicable., connector (spacer for size 2 bushing) to drg. 45176600524-001 rev.05. pvc factor of copper is 1:1.28 at base rate of bme copper index total value (a) as rs. 847.793/kg. (refer bme circular dated 02-05-2025)., earth contact to drg. no. 35170300528 - 002 rev. 10. pvc factor of copper is 1:0.42 at base rate of bme copper index total value (a) as rs. 847.793/kg. (refer bme circular dated 02-05-2025)., earth contact to drg no. 35170300528-001 rev.10. pvc factor of copper is 1:0.48 at base rate of bme copper index total value (a) as rs. 847.793/kg. (refer bme circular dated 02-05-2025)., bus plate (flower -3) to drg. 45176600512-001, rev-05. pvc factor of copper is 1:1.4 at base rate of bme copper index total value (a) as rs. 847.793/kg. (refer bme circular dated 02-05-2025)., isolator fixed contact to drg no. 25170300505-002 rev.10. pvc factor of copper is 1:1.8 at base rate of bme copper index total value (a) as rs. 847.793/kg. (refer bme circular dated 02-05-2025)., breaker side fixed contact for dbb gis to drg no- 35170300106-001. pvc factor of copper is 1:7.12 at base rate of bme copper index total value (a) as rs. 847.793/kg. (refer bme circular dated 02-05-2025)., busbar to drg no. 35176500085-001, rev-00. pvc factor of copper is 1:8.26 at base rate of bme copper index total value (a) as rs. 847.793/kg. (refer bme circular dated 02-05-2025)., earth contact for 2000a to drg 35176300014-001 rev.01 pvc factor of copper is 1:0.62 at base rate of bme copper index total value (a) as rs. 847.793/kg. (refer bme circular dated 02-05-2025)., bus plate (2 leaf) to drawing no 45176600525-001, rev-04. pvc factor of copper is 1:0.800 at base rate of bme copper index total value (a) as rs. 847.793/kg. (refer bme circular dated 02-05-2025)., breaker side fixed contact (1250a) for gis to drg no-35171000195-001 rev.00 for sbb. pvc factor of copper is 1:2.64 at base rate of bme copper index total value (a) as rs. 847.793/kg. (refer bme circular dated 02-05-2025)., top fixed isolator contact (2000a) to drg 25176300005 v00 rev00. pvc factor of copper is 1:1.58 at base rate of bme copper index total value (a) as rs. 847.793/kg. (refer bme circular dated 02-05-2025)., finger contact assembly (3 finger) to drg. 35176300174 v00 rev. 00. pvc factor of copper is 1: 0.72 at base rate of bme copper index total value (a) as rs. 847.793/kg. (refer bme circular dated 02-05-2025)., finger contact assembly (4 finger) to drg. 35176300172 v00 rev 00. pvc factor of copper is 1:0.96 at base rate of bme copper index total value (a) as rs. 847.793/kg. (refer bme circular dated 02-05-2025)., spacer for interrupter (gis) to drg. 35171000177-001 rev-00. pvc factor of copper is 1:2.84 at base rate of bme copper index total value (a) as rs. 847.793/kg. (refer bme circular dated 02-05-2025).
Tender For dismantling, transportation (to & fro), repair, testing, assembling, erection & commissioning of sick power transformer of 31.5mva, 66/11kv bbl make, sl.no4934/5 power transformer failed at 220/66/11kv iti gis pertaining to hoody operation division in the jurisdiction of transmission (o) circle, south, bengaluru on total turnkey basis on percentage tender basis