Tender For tender for supply of supply and installation commissiong d d -supply installation testing and commissioning of 2tr 24000 btu per hour minimum bee 3 star rated confirming to is 1392 part 2 2018 inverter type cassette split ceiling mount air conditioner having wireless remote controller led display for indoor unit motorized vertical horizontal swing controls air filters uto restart with memory features inbuilt drain pump rotary scroll hermetically sealed compressor and initial charge of eco friendly refrigerant condensor and evaporator coils of copper material suitable for operation on 230v 10 single phase 50hz ac power supply the indoor unit shall be suspended from the ceiling using threaded rods including clamps bolts nuts etc and the outdoor unit shall be mounted on floor complete as required , supply and laying of soft drawn copper refrigerant pipe of suitable size for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation including necessary brazing jointing etc as required for cassette split air conditioner as required for item no 1 , supply laying of 4c x 25 sqmm frls pvc insulated 1 1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 25 mm dia minimum thickness of 1 2mm pvc drain pipe along with accessories and necessary clamps with an u trap at the end as required , supply and fixing of 75mm dia minimum 18mm thickness pvc covering pipe using necessary bend colloc clamps threded rod supports accessories etc for laying copper refrigernt line electrical cable and drain line as required. , supply and installation of floor mounted powder coated ms 25 x 25x5mm l angle frame including clamps bolts nuts vibrating dampers as required , drilling of hole using core cutting machine of size up to 100 mm dia in concrete stone wall ceiling for laying refrigerant lines etc and finishing the same with cement mortar after laying , dismantling shifting of old 2tr cassette split air conditioner having indoor and outdoor units associated refrigerant pipes electrical wires and drain pipes including pump down of refrigerant. , making of necessary alteration of existing gypsum false ceiling for installation of cassette air conditioner indoor units including necessary aluminium channel support gypsum board necessary accessories including painting to match for the existing false ceiling , supply installation testing and commissioning of 2tr 24000 btu per hour and iseer value five star rated and compliance with is 1391 part 2 2018 wall mounted inverter type hi wall split cooling inverter air conditioner having wireless remote controller with led display hermetically sealed scroll rotary compressor and eco friendly refrigerant initial charge of refrigerant condensor and evaporator coils of copper material air filter with auto swing auto restart features suitable for operation on 230v single phase 50hz ac power supply the indoor unit shall be fixed rigidly on wall using necessary frame the outdoor unit shall be mounted on floor laying and interconnection of standard length copper refrigerant piping as supplied by the oem between indoor and outdoor units complete in all respects as required necessary drilling of hole and finishing the same to match for the surrounding as required. , supply and laying of beyond the standard length supplied by the oem copper refrigerant pipe of size suitable for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation for hi wall split air conditioner as required for item no 1 , supply laying of 4c x 25 sqmm frls pvc insulated 1 1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 75mm dia minim
Tender For supply of spares-brass female threded spray nozzle suitable for 3/8" dia coupling/sockets provided with stand pipe for air washery ,metalic fresh air filter having size: 630 mm (l) x 630 mm (h) x 50 mm thick with fixing frame, internal construction: 7 ply gi wire netting and frame made from 20 gauge hot dip galvenized gi sheet for air washery
Tender For supply of spares refrigerant gas r407c with cylinder qty:-07 kg per cylinder , shaft seal cover, part no.- , ac926100076, make:- voltas for ac plant compressor model no. 05066-s , 5h s.s. assly with ring, part no.-ac926101800, make:-voltas for ac plant compressor model no. 05066-s , pillow block bearing for ahu of service building ac plant , cleaning chemical (copper safe) for chiller/condenser of ac plant , pillow block bearing model-ucp 205 for ahu of switch yard control room ac package , v belt a-28 , seal cover plate , p.no:ac926100076 make: - voltas for ac plant compressor model no. 05086 , shaft seal assembly , p.no:ac926101800 make: - voltas for ac plant compressor model no. 05086 , charging hose 1/4" connecting (set of 3) for central ac plant , 1/4" charging nrv valve for central ac plant , liquid line filter, make: , voltas for ac plant compressor model no:05086 , v belt b 85 , v belt a-30 , liquid line filter model-165 for uniflair and blue star make package ac unit and hydrogen gas dryer unit , dryer model dcl-083. code.02325005.for blue star make package a.c5.5 ton. , tyre element for fenner make f-80 tyre coupling , refrigeration oil charging pump suitable for voltas make ac plant compressor model no. 05086 , connecting valve for refrigeration oil charging pump suitable for voltas make ac plant compressor model no. 05086 , 3-way manifold gauge set with 3 charging hoses for r22, r134a, r407c for central ac plant , gas cylinder valve spindle key , gas cylinder adaptor for r-22 gas cylinder , gas cylinder adaptor for n2 gas cylinder , air cooled condenser model no: dc85s, capacity: 8.5 tr, make: voltas for 132kv switch yard control room ac package , pedstal bearing size-ucp209d1 for cooling tower of contol room ac plant , brass float valve size: 20 mm (3/4??) , ratchet wrench (4 size: 1/2-inch hex, 9/16-inch hex and 1/4-inch square, 3/16-inch square) , fenner make v belt size b-98
Tender For supply of set of return & fresh air filter for lhb type ac coaches, conf. to rdso spec. no. rdso/pe/spec/ac/0055-2003 (rev.2) with drg no. rdso/pe/sk/ac/0073-2004 (rev-1) and rdso/pe/sk/ac/0074-2004,(rev-1) or latest. as per drg.no. rdso spec. no. rdso/pe/spec/ac/0055-2003 (rev.2) w specn: rdso spec. no. rdso/pe/spec/ac/0055-2003 (rev.2) with drg no. rdso/pe/sk/ac/0073-2004 (rev-1) and rd
Tender For supply of pneumatic lower repair kit part no. 344555 , pneumatic motor repair kit part no. 344666 , injector cap and o ring part no. 400128 , pneu solenoid valve part no. 350006 , 3000mm hose with stud both side part no. 530042 , follower plate part no. 350503 , fm-01 injector part no. 400100 , 2 bank injector with manifold part no. 400117 , 3 bank injector with manifold part no. 400118 , 4 bank injector with manifold part no. 400119 , zerk fitting part no. 400127 , pneu vent valve part no. 400400 , pneumatic vent valve repair kit part no. 400475 , lubrication controller lc-02 part no. 400702 , pipetube rs part no. 400706 , 1700mm hose with stud both side part no. 530041 , polyamide hose 8. 4mm od-4mm id 50m part no. 801001 , 1500mm hose with stud both side part no. 530043 , 1400mm hose with stud both side part no. 530044 , 8000mm hose with elbow and swivel nut part no. 530045 , hose stud part no. 600004 , hose sleeve part no. 600005 , ddr part no. 600013 , pressure gauge 0 - 400 bar part no. 600016 , spray valve nozzel part no. 600041 , elbow we 1 by 8m npt x 7 by 16 unf m part no. 600119 , elbow we 1 by 4m npt x 7 by 16 unf m part no. 600120 , straight ge 1 by 4m npt x 7 by 16 unf part no. 600310 , extension adaptor 1 by 8m x 1 by 8f 15mm part no. 600202 , quick release coupler part no. 601001 , muffler part no. 333029 , fm-01 injector repair kit part no. 400175 , jaguar head repair kit part no. 344888 , air filter regulator unit frl part no. 600020 , jaguar pump station assy 50 kg part no. 350500
Tender For supply of jaguar pump station assy 27 kg part no. 350270 , lubrication controller lc-02 part no. 400702 , air filter regulator unit frl part no. 600020 , fm-01 injector part no. 400100 , fm-01 injector repair kit part no. 400175 , pneumatic motor repair kit part no. 344666 , pneumatic lower repair kit part no. 344555 , polyamide hose 8. 4mm od-4mm id 50m part no. 801001 , jaguar head repair kit part no. 344888
Tender For corrigendum : tender for supply of led indicators for ryb phase 220 v , 22 , mcb / isolators at mains 3 phase 440 v ac 10a , transformer 415/220 ac 45 va , led indicators 220 v , rtd 3 wire pt100 for evaporator pt100 rtd (platinum resistance temperature detector) temperature range -20 degc to +850 degc (+328 deg f to +1562 deg f) , rtd 3 wire pt100 for h2 in or out pt100 rtd (platinum resistance temperature detector) temperature range -20 degc to +850 degc(+328 deg f to +1562 deg f) , cyclic timer (220v ac , setting at 2 hr. on-0.5 hr off) , auto/manual selector dpdt , 6a , 220v ac) allows switching between automatic and manual control modes. , toggle switch auto manual selector & on/off , remote /control card with ac to dc convertor (220v ac to 24v dc) , digital temprature indicator (3.5 digit to 0-99.9 deg rtd class b pt 100 3 wire rtd as sensor) , digital temprature controller with delay timer (3.5 digit 0-10 deg adjustable , dual set point with 10 deg hysterisis and 2 set points , time delay adjustable 0-100 sec sensor 3 wire rtd) , voltmeter (300v , 72x72) , amp. meter (ammeter 0-10a , 72x72) , contactor for compressor (coil 220v 50 hz) , contactor for motor (coil220 v 50 hz) , over load relay for compressor 3 phase , 440v ac) , over load relay for motor (3 phase , 440 v ac) , compressor (3 phase , 440 v 4360 kcal/hr) , fan motor 3 phase , 440v flame proof 0.5 hp is2148 , fan blade (15 inch) typically features aerodynamically designed blades for efficient air moement and reduced noise. , condensor (4 row 16x18 , 3/8 copper with copper with al fins ) , freon receiver (1.5 ton , steel fabricated with copper connection) , freon drier filter (3/8 dcld63) , accumulator (1.5 ton , steel fabricated with copper connection) , hand shut off valve1/2 inch (brass body with ss pin) , hand shut of valve 1/4 inch (brass body with ss pin) , hand shut off valve 3/8 brass body with ss pin) , pressure guage 500 psi (350 psi operation value 20 psi to 35psi) , pressure guage 500 psi (500 psi operation value 200 psi to 70 psi) , water collection chamer ss 316 (fabricated complete in stainless steel , including 2 nos of ss drain valve & complete ss drain line nb20 from evaporator recommended by the oem 0 chance of break and escape of hydrogen. , capillary (0.64 copper tube with stainer) , drain valve (dn15 , cs body ss ball , teflon seat) , hp/lp pressure switch (kf -15/mp-15 , low set point at 5 psi and high set point at 350 psi) , complete precooler in (ss316) with inbuilt copper bundle , end plates and flanges , complete evaporator in (ss316) with spiral form cooling coil ( only with 4 joints instead of 104) , h2 interconnections ss316 welded with 4 flanges , spiral form cooling coil only for evaporator (only with 4 joints instead of 104) , refrigerant gas (r-407) (8 kg) in cylinder , gaskets (1 set) (neoprene) made from high-quality rubber of silicone) , flare nuts (1 set) refrigeration brass flare nuts , designed to fit standard refrigeration tubing sizes and flare fittings. , thermostatic expansion valve 3by8 function regulates the flow of refrigerant into the evaporator coil based on temperature and pressure conditions. , theromowell in ss316 250 mm , solenoid valve 3by8 flare fitting