Get complete information related to latest Glass Filter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Glass Filter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Glass Filter Tenders.
Tender For corrigendum : 9060c26a70 rprc265074 annual rate contract for deputation of field service expert for inspection health assessment trouble shooting maintenance and overhauling of mkk make rotary vacuum filter and tsk make cta pta steam tube dryers of pta unit at panipat refinery - rprc265074 rate contract for deputation of field service expert for inspection, health assessment, trouble shooting, maintenance and overhauling of mkk make rotary vacuum filter and tsk make cta/pta steam tube dryers of pta unit at panipat refinery & petrochemical complex.
Tender For purchasing spares for minimac make oil filtration machines installed in turbine governing system skid and hplp bypass hpsu skid installed in turbine area in unit 5and6 (2x660 mw) csctpp, chhabra is proposed to be procured through single source - - air release valve, modelno:-dbv-14, 1/2"bsp ,brass, nbr seat,0-7kg/cm2,230v ac, 9w, h class 230 ac coil, filter clogging indicator for cu series filter, first stage10-micron filter element with 99.8% efficiency, beta-1000, make: minimac, part no: mscufefa10, foam sensor, lbfs, low level switch, mfps-n15c, differential: ±3 mm, switching voltage max:140vac/200 vdc, switching current max:0.5a, middle level switch, mfps-n15c, differential :±3 mm, switching voltage max:140 vac/200 vdc, switching current max:0.5a, n2 filter (tmr unit), n2 flow meter (tmr unit), pre-heater, 6000-watt heater element, 415 v,3 ph, length 460mm, ms flange od 160 mm, pcd-134 mm,6 hole size 9.5 mm filter elemen for pre-heater, pressure gauge 63 mm dia, pump oil seal and o-ring (rotary gear pump) (white tone), resin for trix machine, part no: mspl-rsn100, safety level switch, mfps-n15c, model no. mfps-n15c(m), level indication, low levels, 1/2" bsp liquid sp.gr.min:0.8, temperature max: 130°c test pressure max:5kg/cm2, moc: ss304 float:ø17, connection: 1/2"bsp(m), second stage 03-micron filter element with 99.8% efficiency, beta-1000, make: minimac, part no:mscufefa03, solenoid valve with diaphragm, model no:mcv-43., 1" bsp, cf8,0.5-12 bar pressure, 24 v dc coil, solenoid valve, modelno:-dbn-14z, 1/4" bsp,brass,nbr seat,0-7kg/cm2,230v ac, 9w, h class 230 ac coil, suction strainer 149-micron filter element, make: minimac, part no: ms20-m 149, temperature gauge 63 mm dia, temperature sensor, vacuum gauge 63mm dia, vacuum pump with oil seal, o-ring, filter, nrv, vacuum switch with fitting, model no:-mg-v-00-ka10, vacuum switc
Tender For corrigendum : tender for the supply of various equipments required for upgradation of district food laborartory, karnal - muffle furnace, "al2o3 sample plate, al2o3 furnace door block, protection glove, crucible clip, crucibles", karl fischer titrator, "titration vessel, detector electrode with lead, generator electrode (with frit) with lead, desiccant tube and cap, injection septa (pack of 10), gas tight syringe 1.0ml , luer needle 17-gauge, dust cover, results manager software, main power pack, fuse, karl fischer titration reagent(s), nist calibration standard", refrigerated centrifuge (bench top),, bottles/falcon tubes/adapters for 0.2ml tubes, one set of other items (adapters) required for improving the applicability/system performance should to be quoted, nitrogen evaporator, evaporation tubes, gas fuse , water purification system including water softner, cartridges, filters etc. for , bomb calorimeter, "ignition wire, cotton thread, combustion crucible, bomb, nist certified benzoic for calibration, any other accessories required for analysis of food samples.", gas chromatograph with ecd, tcd, fid with autosampler, "pesticide column (30 m x 0.250mm x 0.25µm (5ms (95% dimethyl-, 5% diphenyl-polysiloxane / 1ms (100% dimethyl polysiloxane or equivalent) 100 mm column for fatty acid profiling with main concern of trans fatty acid application, column for cholesterol application, stationary phase: 95% dimethyl-, 5% diphenyl-polysiloxane (30 m x 0.250mm x 0.25µm),", "vial sets (1, 2 ml, crimp type, amber and clear glass), vials (10, 20ml crimp type with cap & septa), 300/500 µl recovery vials, septa ptfe/silicone (for 1, 2 ml vials), septa ptfe/silicone (for 10, 20 ml headspace vials), ergonomic crimping tools for different vial types, ergonomic decapping tools for different vial types, head space vials 10,20 ml capacity, suitable syringes for quoted autosampler, suitable headspace syringe /valve/loop, quechers kits for pesticides and herbicides in following matrices:matrices with high fat, matrices with high water content, matrices with high pigmented, spe cartridges for water.", ultra performance liquid chromatography (uplc) with photodiode array (pda), fluorescence (fld) and refractive index detector (rid), sample vials with 1.5 ml or greater, stainless steel ultra sonic bath with the capacity of 5 l or more, with time setting (min) 1-30min or continuous operation with led and push button (should be ip 33 protection class) for sonication of spare parts as well as solvents, fittings, frits, ferules and tubing’s, tubing cutter, solvent bottles (1000 ml capacity), solvent filters (glass & ss both, compatible manual syringes -10 µl, 20 µl, 50 µl, standards for hplc calibration for pda, ri and fluorescence detector, consumables required for each detector must be provided., "hplc columns: one each ofc8 = 250 × 4.6 × 5μm c18 = 250 × 4.6 × 5μmcyano = 250 × 4.6 ×5μm. amino = 250 × 4.6 × 5μmphenyl = 250 × 4.6 ×5μm. silica = 250 × 4.6 × 5μm.all columns must be supplied with respective guard column and holder. ", uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glassfilters for wavelength calibration & nist traceable, nist traceable potassium dichromate.", uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glassfilters for wavelength calibration & nist traceable, nist traceable potassium dichromate.", ft-ir with atr & liquid cell, "• hydraulic press with kbr die and pellet holder• suitable mortar pestle (dia 5-6 cm)• suitable portable de humidifier to maintain 30- 60% rh• temperature and relative humidity digital indicator with calibration certificate from iso 17025 accredited lab.• ref
Tender For supply of consumables for sps lab e e - mounted superachromatic quarter wave plate , fiber collimation package , mounted led 365 nm , mounted led 415 nm , mounted led 530 nm , mounted led 780 nm , mounted led 850 nm , mounted led 1100 nm , mounted led 1550 nm , aluminum breadboard , led driver , colored glassfilter kit