Tender For supply of blood bank chemicals and accessories to district govt. hospital of udupi district. - syringe 2ml_, syringe 5ml_, plastick roller_, portable doner bed_, temperature cloth humidity digital_, in out thermohygrometer_, distilled water _, vdrl elisa_, ahg coombs test gel card_, abd blood grouping card reagent_, binocular microscope with battery back up_, double bucket equilizer_, automated blood component extractor_, automated hematology analyzer_, donor couch with blood collection monitor_, fully automated eliza processer_, apheresis machine_, hot air oven_, eliza washer_, automated eliza reader_, tube sealer_, cryo bath_, laminar air flow chamber_, auto clave_, thermographs godrej refrigerator 2minus8 with fibre tip pen each_, thermographs remi minus 40c_, autoclave indicators strips tape_, slipper half shoe type_, leukocyte deduction filtar_, room thermometer digital_, plasma expressor _, douner couch_, platelet ageteter with incubator_, minus 80 de freezer_, minus 40 de freezer_, minus 20 de freezer_, refrigerator 2 to 8c _, refrigerated centrefuge 16 bucket_, refrigerated centrefuge 12 bucket_, refrigerated centrefuge 8 bucket_, incubator_, vdrl rotatary shaker_, sponge balls_, marcuryless bp appartus led_, wrist bp appartus_, centrefuge double pan bucket equalizer_, qc hcv eliza_, qc hbsag_, qc hiv eliza_, pippettes 100 to 1000ul variable_, pippettes 20 to 200ul variable_, pippettes 10 to 100ul variable_, pippettes 05 to 100ul variable_, centrifuge 12 tubes _, dispossable donor couch sheets_, gelcard monitor analyser_, table top centrifuge_, du test gel card_, blood grouping gel card_, factor 9 assay reagent factor 9 defecient plasma_, factor 8 assay reagent factor 8 defecient plasma_, aptt reagent_, pt reagents_, circulating water bath 08ltrs_, hb machine_, blood weighing thing scale manual_, donor weighing scale manual_, cryo gloves_, plasma expressor_, multy channel micropipette_, thermographs thermopenpol 2 to 8 degree c each_, bar code sticker each_, lables small each_, vinyle gloves powder free each_, thermographs thermopenpol minus 80c with fibre tip pen each_, thermographs thermopenpol minus 40c with fibre tip pen each_, thermographs remi 2 to 8c with fibre tip pen each_, thermographs jewet 2 to 8c with fibre tip pen each_, bullet tubes each_, hb percent strips hemocue each _, anti human globulin ml_, bovine albumin ml 22 percent _, clamping clips each_, ph strips each_, tube connecting wafers_, anti d igm igg bounded compound 5ml pack_, anti d igg 5ml_, ors l_, blue tips 1000u each_, eliza printer role each 57 mm_, anti ab ml_, anti h ml_, anti a1 ml_, anti d ml_, anti b ml_, anti a ml_, blood transfusion sets each_, normal saline ml_, glass slide each_, glass test tube 5ml_, glucose powder 500 grm_, button activated safety lancets each_, non vaccume edta tubes each_, non vaccume plain tubes each_, yellow tips 200m_, tissue role 2ply 10cmx40mtrs_, hand plaster round each_, mp spot kits per test_, rpr kits per test_, vdrl spot kits per test_, hcv spot kits per test_, hcv eliza kits per test_, hbsag spot kits per test 4th generation kits_, hbsag eliza kits per test 4th generation kits_, hiv spot kits per test 4th generation kits_, hiv eliza kits per test 4th generation kits_, liss solution per ml_, ortho bio vue igg per test_, pediatric bag_, penta bags_, triple blood bag 450ml_, triple blood bag 350ml_, double blood bag 350ml_, double blood bag 450ml_, quadraple blood bag 450ml_, quadraple blood bag 350ml_, single blood bag 350ml_
Tender For corrigendum : various routine/preventive and breakdown maintenance work on as and when require basis at chp-gtps - replacement of hammer rings for stage ii crusher , replacement of hammer rings for stage i crusher , replacement of screen plate / breaker plate/kick off plate of stage i and ii crushers , replacement of rotor of stage i crusher with disassembling of removed rotor and assembling of new/repaired rotor , replacement of drive end side bearing / pedestal of crusher rotor or complete gear coupling set of crusher or repositioning of dislocated rotor of crusher , replacement of non drive end side bearing/pedestal of crusher rotor or complete alignment of crusher motor with crusher rotor , replacement of broken hammer rings of stage i and ii crushers (stage i crusher up to 12 nos.of hammer rings and stage ii crusher up to 06 nos. of hammer rings at a time) , replacement of rail of rail table of wagon tipplers 1/2/3/4 (in one side full length) , replacement of clamping rubber pads of clamp for wagon of wagon tipplers , replacement of whole resting pads for wagon of side beam of wagon tipplers , replacement of spill plate roller of wagon tipplers , repairing/preparation/ fitting and replacement of hooks/rods/turn buckle, chain, sling rope ,spring assembly etc. of vibrating trays and crusher house trays , spillage control at various locations , miscellaneous cutting/welding work require at various locations , replacement of gearbox in conveyor no. 2a/b,11a/b,12a/b,13,14/15,16a/b,17a/b ,18a/b,drc/apron/rg/,wagon tipplers,stacker-reclaimer , replacement of gearbox in conveyor no.,5a/b,8a/b,10a/b,shuttle conveyor 1/2,belt feeder 1/2 ,roller screen, mrc 3/4/5,wobbler feeder ,dribble conveyor 1/2 , replacement of slow speed coupling set (two halves) of drive pulley , replacement of coupling bolts and rubber bushes of slow/high speed coupling(input/output coupling ) in conveyor no.2a/b,11a/b,12a/b,13,14/15,16a/b,17 a/b,18a/b,drc/apron/rg/,wagon tipplers,stacker-reclaimer , replacement of coupling bolts and rubber bushes of slow/high speed coupling(input/output coupling ) in conveyor no.,5a/b,8a/b,10a/b,shuttle conveyor 1/2,belt feeder 1/2 ,roller screen, mrc 3/4/5,wobbler feeder ,dribble conveyor 1/2 , replacement/removing/refitting of various size and type of fluid coupling , replacement or removing & refitting of any internal/bearing/input/ output oil seal of various size and type of gear box , overhauling of dismantles old/used gearbox in all respect with fitment of input and output coupling. , replacement of drive pulley , replacement of drive end side bearing of drive pulley or repositioning of dislocated drive pulley , replacement of non drive end side bearing/any side pedestal of conveyor drive/non drive pulley , alignment of motor/ gearbox/drive pulley including decouple/couple of coupling , nut bolt and drive system checking with replacement of broken nut bolt in all 04 wagon tipplers no.1/2/3/4 as per scope , lifting and releasing of gravity take up of any conveyor belt for locking and de locking of belts for other than belt replacement work , loosening and tightening of horizontal type screw take assembly of any conveyor belts for other than belt replacement work , work of dismantling and re erection of new/repaired apron pan from existing apron feeder of wagon tippler , repairing of upper/lower structure/cone plates of damaged/bend apron pan , replacement of carrying roller of apron feeder , replacement of worn out/ damaged ti roller and garland rollers. , replacement of worn out/ damaged impact rollers , replacement of worn out/ damaged return rollers , replacement of various worn out/ damaged ti roller stands , replacement of various worn out/ damaged impact roller stands , replacements of various worn out/ damaged return roller stands , replacement of various worn out skirt rubbers [10 m each] and skirt rubber with angle , preparation and replacement of guide rollers with bracket in place of worn out/ damaged gu
Tender For supply, installation & commissioning of hydraulic job clamping wise for fixing of avm pads to 60kva lhb ac transformers on table (with work table, power pack, panel box & clamping wise with cylinder) with accessories consisting the following items and drawing en closed. 1) work table of size:1900x800x750 with top ms sheet of 8mm thickness 2) clamping wise with cylinder (heavy duty). 3) hydraulic p ower pack of electrical pump operated for hydraulic operation with foot pedal switch with 3hp motor, 5lpm pump, m28 coupling, bell hou se, manifold block, valve 240v, relief valve, suction strainer, breather, oil level indicator, pressure gauge, 70lts reservoir, oil grade syste m-68, electrical control panel with electrical safety for men working and equipment. [ warranty period: 30 months after the date of deliver y ]