Web Analytics Made Easy - StatCounter

Gritty Sale Tenders

Get complete information related to latest Gritty Sale Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Gritty Sale Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Gritty Sale Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :38566490 Due date: 20 Dec, 202420 Dec, 2024 NA
Location: Goa - Goa Goa - Goa
Tender For item based annual maintenance contract of air conditioner works for csir nio institute building campus and csir science centre, dispensary and international hostel etc., at nio colony, dona paula, goa

State Government

CTN :38578529 Due date: 21 Dec, 202421 Dec, 2024 NA
Tender For 3d printing technology for anganwadi building (online quotation) non dsr item.

Central Government/Public Sector

CTN :38526735 Due date: 31 Dec, 202431 Dec, 2024 48.00 Lacs
Tender For repair maint of lt panel, feeder pillar boxes, junction boxes to building, lt distribution system and connected item in zone b tech area under ge (af) tech area agra

Central Government And Public Sector

CTN :38292574 Due date: 19 Dec, 202419 Dec, 2024 68.32 Lacs
Tender For providing of custom bid for services - ustom bid for services -enabling contract for erection & commissioning of ba/bb board for unit # 3 & unit # 6 (mc-5261)- item 1 dismantling & removal ba: dismantling and removal of existing installation of floor mounted cubical type 6.6 kv, 3 phase, 50 hz, vacuum circuit breaker ba board containing 16 nos breaker panel, and approximate size 14000 mm x 2150 mm x 2800 mm (lxdxh) at ei. 7.5 mtr in unit switchgear room at electrical annex building of power house. all the scrap generated from this is to be shifted to the designated place at scrap yard as per the direction of the mic. 2.00 set, item 2 dismantling & removal bb: dismantling and removal of existing installation of floor mounted cubical type 6.6 kv, 3 phase, 50 hz, vacuum circuit breaker bb board containing 17 nos breaker panel, and approximate size 14500 mm x 2150 mm x 2800 mm (lxdxh) at ei. 7.5 mtr in unit switchgear room at electrical annex building of power house. all the scrap generated from this is to be shifted to the designated place at scrap yard as per the direction of the mic. 2.00 set, item 3 installation including issue-ba: installation including issue from nalco s store, transportation to erection site, storage at site, erection of floor mounted cubical type 6.6 kv, 3 phase, 50 hz, vacuum circuit breaker ba board containing 16 nos breaker panel, and approximate size 14000 mm x 2150 mm x 2800 mm (lxdxh) at ei. 7.5 mtr in unit switchgear room at electrical annex building of power house including supply of all erection accessories and consumable etc for complete and satisfactory installation of the switchboard in all respect.testing of all the 6.6kv panels including ct, pt, breakers, spds, logics and interlocks, auxiliary relays, numerical relays, cables(both ht and lt) 2.00 set, item 4 installation including issue-bb: "installation including issue from nalco s store, transportation to erection site, storage at site, erection of floor mounted cubical type 6.6 kv, 3 phase, 50 hz vacuum circuit breaker bb board containing 17 nos breaker panel, and approximate size 14500 mm x 2150 mm x 2800 mm (lxdxh) at ei. 7.5 mtr in unit switchgear room at electrical annex building of power house including supply of all erection accessories and consumable etc for complete and satisfactory installation of the switchboard in all respect.. testing of all the 6.6kv panels including ct, pt, breakers, spds, logics and interlocks, auxiliary relays, numerical relays, cables(both ht and lt) 2.00 set, item 5 dismantling of 6.6kv 3cx185 sqmm: dismantling of 6.6 kv (ue) grade xlpe insulated, armoured, aluminium conductor frls cables of following sizes on cable trays at cable trench/structures after removal of clamps, trefoil clamps etc. the cables shall be kept properly at the designated place as per the direction of mic and later hand over the same at the central store scrap yard. 3cx185 xlpe cable 3000.00 meter, item 6 dismantling of 6.6kv 1x500m: dismantling of 6.6 kv (ue) grade xlpe insulated, armoured, aluminium conductor frls cables of following sizes on cable trays at cable trench / structures after removal of clamps, trefoil clamps etc. the cables shall be kept properly at the designated place as per the direction of mic and later hand over the same at the central store scrap yard. 1cx500 xlpe cable 2500.00 meter, item 7 cable laying including issue 3cx185sqmm: cable laying including issue from nalco s store, transportation to erection site, storage at site of 6.6 kv (ue) grade xlpe insulated, armoured, aluminium conductor frls cables of following sizes on cable trays in cable trench/structures including supply of cable installation accessories viz clamps, trefoil clamps, nylon ties, identification tags, hooks, saddles, spaces, rawl plugs, anchor fasteners, bolts, nuts, washers, sealing materials for pipe sleeves, etc and all other consumable materials to render the system complete in all respect. 3cx185 sqmm xlpe cable. 3000
 Loading, Please wait...

Connect us via What's Up