Get complete information related to latest Guide Pole Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Guide Pole Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Guide Pole Tenders.
Tender For supply of ptz cameras , led monitor , ip based network thermal imaging cameras , pole mounting stand 10 mtrs , cctv camera power supply , supply, laying of cctv cable in existing cable trenches through pipes , client workstation with graphic card , server with 20tb storage capacity , turnstiles with door controllers , biometric reader , smart cards , server , software for access control system , 24 port l2 or l3 manageable switch , supply of cat-6-utp cable , single information outlet with smb having shutter facility , supply of cat 6 utp patch cord-1mtrs , supply of cat 6 utp patch cord-3mtrs , 24 port cat 6 utp jack panel with cable manager , 6 core sm double sheath, csta, unitube, outdoor cable , sc-lc duplex fibre patch cord , 6 port sm liu fully loaded with 06 simplex sc couplers and 06 sc connector , 19 inch 6u 600mm depth rack with accessories , 42u rack with 1000m depth with accessories , hdpe pipe 32 mm , pvc pipe , casing and capping , supply of gi pipe , fixing of 24 port utp cat6 jack panel , fixing of rack , fixing of liu , digging of hard soil , sc connectorisation per core , fiber laying per meter , laying of utp cable per meter , fixing of information outlet per unit , 2 kva ups with 60 min backup , transceiver , supply of rj-45 connectors as per requirement , newn junction boxes , supply of telephone exchange , supply of 2 kva ups with 1 hr back up , cli telephone instruments , supply of telephone cable 2 pair 0.5mm stealth with polythene cover , 50 pair mdf with modules, metal enclosure with lock and key , 100 pair mdf with modules, metal enclosure with lock and key , 200 pair mdf with modules, metal enclosure with lock and key , supply of rj-11 boxes , supply of casing and capping per meter 1.5 inch , laying of telephone cable along with casing and capping , installation and commissioning charges
Tender For corrigendum : supply of electrical equipment's and fire equipment's systems-, winng bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface recessed steel conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc as reqd. , group c , wiring for light/ power plug with 2x4 sq mm frls pvc insulated copper conductor single core cable in surface/recessed steel conduit along with 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. , wiring for light/ power plug with 4x4 sq. mm frls pvc insulated copper conductor single core cable in surface/recessed steel conduit along with 2 nos. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. , supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface/recessed steel/ pvc conduit as required. , 3 x 1.5 sq. mm , 6 x 1.5 sq. mm , 3 x 4 sq. mm , 6 x 4 sq. mm , 3 x 6 sq. mm , wiring for circuit/ submain wiring along with earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed steel conduit as required. , 2x1.5 sq. mm 1x1.5sq. mm earth wire , 2 x 2.5 sq. mm 1x2.5 sq. mm earth wire , 4 x 2.5 sq. mm 2 x 2.5 sq. mm earth wire , 4 x 4 sq. mm +2 x 4 sq. mm earth wire , supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. , 20 mm , 25 mm , supplying and fixing suitable size gl box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pins 5/6- & 15/16-amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. , supplying and fixing suitable size gl box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos 3 pin 5/6 amps modular socket outlet and 2 nos 5/6 amps modular switch, connection, painting etc as required. , supplying & fixing suitable size gi box with modular plate and cover in front on surface or in recess including providing and fixing 25 a modular socket outlet and 25 a modular sp mcb, "c" curve including connections, painting etc. as required., )8 way (4+24), double door , 2, supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. , supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. , 5/6 a switch , - 2-way 5/6 a switch , 15/16 a switch , )3 pin 5/6 a socket outlet , 6 pin 15/16 a socket outlet , telephone socket outlet , tv antenna socket outlet , 4, supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , 5, 1, ( , supplying and fixing following size/ modules, gl bax along with modular base & cover plate for modular switches , in recess etc. as required. 8 module (125mmx125mm) , 12 module (200mmx150mm) , supplying and fixing 3 pin, 5 a ceiling rose on the existing junction box/ wooden block including connections etc. as required. , providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface/recessed conduit/ submain wiring/ cable as required , supplying and fixing cable route marker with 10 cm x 10 cm x 5 mm thick g.i. plate with inscription there on, 8 bolted/welded to 35 mm x 35 mm x 6 mm angle iron, 60 cm long and fixing the same in ground as required. , providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders in existing cub