Tender For supply of spares refrigerant gas r407c with cylinder qty:-07 kg per cylinder , shaft seal cover, part no.- , ac926100076, make:- voltas for ac plant compressor model no. 05066-s , 5h s.s. assly with ring, part no.-ac926101800, make:-voltas for ac plant compressor model no. 05066-s , pillow block bearing for ahu of service building ac plant , cleaning chemical (copper safe) for chiller/condenser of ac plant , pillow block bearing model-ucp 205 for ahu of switch yard control room ac package , v belt a-28 , seal cover plate , p.no:ac926100076 make: - voltas for ac plant compressor model no. 05086 , shaft seal assembly , p.no:ac926101800 make: - voltas for ac plant compressor model no. 05086 , charging hose 1/4" connecting (set of 3) for central ac plant , 1/4" charging nrv valve for central ac plant , liquid line filter, make: , voltas for ac plant compressor model no:05086 , v belt b 85 , v belt a-30 , liquid line filter model-165 for uniflair and blue star make package ac unit and hydrogen gas dryer unit , dryer model dcl-083. code.02325005.for blue star make package a.c5.5 ton. , tyre element for fenner make f-80 tyre coupling , refrigeration oil charging pump suitable for voltas make ac plant compressor model no. 05086 , connecting valve for refrigeration oil charging pump suitable for voltas make ac plant compressor model no. 05086 , 3-way manifold gauge set with 3 charging hoses for r22, r134a, r407c for central ac plant , gas cylinder valve spindle key , gas cylinder adaptor for r-22 gas cylinder , gas cylinder adaptor for n2 gas cylinder , air cooled condenser model no: dc85s, capacity: 8.5 tr, make: voltas for 132kv switch yard control room ac package , pedstal bearing size-ucp209d1 for cooling tower of contol room ac plant , brass float valve size: 20 mm (3/4??) , ratchet wrench (4 size: 1/2-inch hex, 9/16-inch hex and 1/4-inch square, 3/16-inch square) , fenner make v belt size b-98
Tender For bid to ras tender for supply of job order for urgent repair of transformer of cap 400 kva at mil stn kalka : : - disconnecting ht and lt supply taking down the defective transformer indoor outdoor type from four pole two pole structure or lifting from the outdoor type foundation or taking out from sub station bldg using a crane of suitable capacity and slings ropes etc as required and shifting the same to civil workshop for repairs complete all as directed for transformer capacity 400 kva , shifting back the repaired transformer indoor outdoor type from civil workshop to site reinstalling at original position and fixing properly on four pole two pole structure or outdoor type foundation or inside a sub station bldg using a crane of suitable capacity and slings ropes etc as required making ht lt side connections and testing for satisfactorily working complete all as directed for transformer of capacity 400 kva , draining out transformer oil from the transformer and storing the same in suitable containers to be arranged by contractor without any extra cost opening the top cover and lifting up the core assembly carefully to check the condition of transformer windings and core retanking the same after repairing checking of leakage from transformer body and repairing welding works required for making transformer body leak proof refilling the transformer oil dully dehydrated and filtered dehydration and filteration to be paid separately and making all connections with ht lt side bushings refixing the top cover and testing the transformer with a suitable capacity insulation tester complete all as directed for transformer of cap 400 kva , m and l for rewinding of burnt out defective ht copper coils with new super enamelled heavy duty copper winding wires of size matching to the existing one including varnishing drying in a suitable oven and all insulating material such as cotton sleeves tapes etc and connections with bushing terminals complete all as specified and directed , all as per item no 4 above but lt copper coils complete all as specified and directed , m and l for painting the transformer tank from inside with two coats of zinc chromite after preparing the tank walls bottom top cover inner side by properly cleaning the surfaces oil free complete all as directed for transformer capacity 400 kva , m and l for replacement of defective ht porcelain bushing of suitable size for transformer of cap 400 kva including washers of good quality complete all as specified and directed , m and l for replacement of defective lt porcelain bushing of suitable size for transformer of cap 400 kva including washers of good quality complete all as specified and directed , dehydration and filteration of transformer oil for indoor outdoor type transformers of any capacity at site using transformer oil filteration plant to improve di electric strength not less than 45 kv at 2 point 5 mm electrode gap complete all as directed note unit rate quoted shall be deemed to include the charges for hiring of oil filteration plant shifting to different locations at cantt area testing of samples of oil as per requirement and nothing extra will be paid on this account , s and f new transformer oil for replacement or topping up the level of oil having dielectric strength not less than 45 complete all as specified and directed
Tender For corrigendum : - supply & installation of various items under the scheme “installation of 220kwp on grid solar power plant at sidco, leh under sdp 2025-26” - complete 1 set also refer the tender documents for requirement. 2. installation of existing solar panel mono perc at sidco office leh (60kwp)2.module mounting structure for ground mounted for 35kwp with clamps & fastener etc3.supply & installation of 60kwp grid tie solar inverter 4.net metering5.al armored cable 3.5c, 35sqmm, 550mtr 1c, 4sqmm, 1200mtr copper cable, mc4 connectors6.inverter device remote monitoring system7.gi tray, pipes etc8.array junction boxes, acdb, dcdb, earthing , la etc9.civil works as per requirement for 35kwp solar panel installation,
Tender For auction sale of dslam 480 port with card-9 with subs cable upto mdf, etc,ewsd dlu rack two nos with 50 cards and subs cable, etc,ewsd dlu one rack and 10 cards with subs cable upto mdf,power plant 100 ah-01 with one module, etc,power plant, etc,210 single band gsm 900/utms 2100 antenna as is where is basis,12 dslam of utstarcom make with 27 cards and subs cable, etc,2 dslam of huawei make with 17 cards,0.5 k 6 dlu of seimens make with 75 cards,ewsd dlu one rack make with 16 cards,pijf duct cable (800 pair-72 meter) as is where is basis,five scrap pkg ac units (along with copper pipping & cables from indoor, etc,three scrap capcaitor panels of 50 kvar,8 nos of scrap dgs control panel (conventional type),40 mtr gbt, as per lot description,old iron scrap
Tender For supply of pdg high energy efficiency solar photovoltric module of 15 kwp or above manufactured in india etc complete , power conditioning unit pcu suitable for 15 kwp solar photo voltricpower generation system etc as required , module mounting structure on the roof top solar plant generation unit shall be installed , real time online web interfaced data monitoring system complete with accessories of 15 kwp solar photovoltric module etc , array junction box and main junction box with ip 65 protection and termination arrangement for incoming and outgoing cable , lightning surge voltage protection earthing protection etc , cables connections and interconnections by required size ir or uv protected xlpe insulated copper conductor cable , dc distribution board and ac distribution panel board ip65 free standing, metal cladded etc
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - onboard in ships at naval dockyard, mumbai; repair rate agreement (rra) for 01 year and extendable upto 02 more years for repair/ renewal of copper & copper nickel pipes..
Tender For corrigendum : supply of 6.6 kv epr insulated flexible trailing power copper cable for elecon make stacker cum reclaimer machine of coal handling plant at wtps