Web Analytics Made Easy - StatCounter

Half Wiper Tenders

Get complete information related to latest Half Wiper Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Half Wiper Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Half Wiper Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :41554033 Due date: 31 Oct, 202531 Oct, 2025 4.32 Lacs
Tender For bid to ras tender for supply of mpcb and mcb make siemeans or schnieder : : - motor protection circuit breaker asper iec 947 having magnetic thermal release with 1no aux contact range 2.5 - 4 amps make siemens or schnider , motor protection circuit breaker asper iec 947 having magnetic thermal release with 1no aux contact range 0.25 - 0.4 amps make siemens or schnider , motor protection circuit breaker 10-16 amps 3pole over load range 10 -16 amps 1n0 make siemens or schnider , air break contactor ac3 duty 4kw dol minimum current rating 9a aux.contacts 2no+2nc coil voltage 220v 50/60 hz along with suitable coil suppressor make siemens or schnider , air break contactor ac3 duty 5.5kw dol minimum current rating 12amps aux contacts 2no + 2nc coil voltage 220v 50/60 hz make siemens or schnider , air break contactor ac3 duty 4kw dol minimum current rating 9 a aux contact 1no coil voltage 220v 50/60 hz along with suitable coil suppressor make siemens or schnider , miniature circuit breaker as per is 8828 1966 iec 898 c type 1amp sp breaking capacity 10 ka make siemens or schnider , miniature circuit breaker asper is8828-1996 iec 898 c type 2amps sp breaking capacity 10 ka make siemens or schnider , miniature circuit breaker as per is 8228 1996 iec 898 c type 6amps sp breaking capacity 10 ka make siemens or schnider , miniature circuit breaker as per is8828 1996 iec 898 type c 4 amps dp breaking cap 10ka make siemens or schnider , miniature circuit breaker , asper is8828 1996 iec 898 c type 6 amps dp breaking capacity 10 ka make siemens or schnider

Central Government/Public Sector

CTN :41705612 Due date: 31 Oct, 202531 Oct, 2025 NA
Tender For bid to ras supply of mcb and air break contactor d d - e4653101_1-bp9047585925-mcb 4 pole, 63a, 440vac, 45- 65 hz, curve c type as per bhel spec no. cee23016 rev-00 item 001. , 2-bp9047585933-mcb 4 pole, 32a,440vac, 45-65 hz, curve c type as per bhel spec no. cee23016 rev-00 item 002. , 3-bp9047585941-mcb 2 pole, 6a, 240vac, 45-65 hz, curve c type as per bhel spec no. cee23016 rev-00 item 003. , 4-bp9047585968- mcb 2 pole, 20a, 240vac, 45-65 hz, curve d type as per bhel spec no. cee23016 rev-00 item 004. , 5- bp9047585976-mcb 2 pole, 6a, 220dc, as per bhel spec no. cee23016 rev-00 item 005. , 6-bp9047585984-mcb 2 pole, 2a, 220dc, as per bhel spec no. cee23016 rev-00 item 006. , 7-bp9047585992-add-on contact block for mcb item 1 - item 6, 1 co, 6a as per bhel spec no. cee23016 rev-00 item 007. , 8-bp9047586000-mpcb 3 pole, 2-4a, 415v ac, 45-65 hz, 1 no and 1 nc, as per bhel spec no. cee23016 rev-00 item 008. , 9- bp9047586018-mpcb 3 pole, 6-10a, 415v ac, 45-65 hz, 1 no and 1nc, as per bhel spec no. cee23016 rev-00 item 009. , 10-bp9047586026-mpcb 3 pole, 4-6a, 415v ac, 45- 65 hz, 1 no and 1 nc, as per bhel spec no. cee23016 rev-00 item 010. , 11-bp9047585119-contactor 3-pole, rating 9a ac3 duty with 2 no and 2 nc aux. contacts as per bhel spec no. cee22020 rev-00 item-1. , 12- bp9047585127-contactor 3-pole, rating 16a ac3 duty with 2 no and 2 nc aux. contacts as per bhel spec no. cee22020 rev-00 item-2 , 13-bp9047585100-off load isolating switch 4-pole, 150a with 2 no and 2 nc aux. contacts as per bhel spec no. cee22020 rev- 00 item-3 ) /bid number : gem/2025/b/6643801 * /dated: 04-09-2025 & & / bid document 1 / 16

CTN :42187478 Due date: 29 Oct, 202529 Oct, 2025 NA
Tender For supply of air break contactor, 415 v, 50 hz, 3 phase, ac - 3 rated current - 140 a, 2 no+ 2 nc, type: 3tf51 0 , contactor, 3tf50, 110 a, 230 v ac coil, aux. 2 no+ 2 nc. make: si , contactor, 3tf49-22-0a-m0-za01, 85 a, 220 v ac coil, aux. 2 no+ 2 nc. , contactor, 3tf48, 75 a, 230 v ac coil, aux. 2 no+ 2 nc. make: sie , air break contactor rated current ac3, 70a, 415 - volts, 50 hz, with a. c. coil operating coil voltag
 Loading, Please wait...

Connect us via What's Up