Tender For corrigendum : tender for the supply of various equipments required for upgradation of district food laborartory, karnal - muffle furnace, "al2o3 sample plate, al2o3 furnace door block, protection glove, crucible clip, crucibles", karl fischer titrator, "titration vessel, detector electrode with lead, generator electrode (with frit) with lead, desiccant tube and cap, injection septa (pack of 10), gas tight syringe 1.0ml , luer needle 17-gauge, dust cover, results manager software, main power pack, fuse, karl fischer titration reagent(s), nist calibration standard", refrigerated centrifuge (bench top),, bottles/falcon tubes/adapters for 0.2ml tubes, one set of other items (adapters) required for improving the applicability/system performance should to be quoted, nitrogen evaporator, evaporation tubes, gas fuse , water purification system including water softner, cartridges, filters etc. for , bomb calorimeter, "ignition wire, cotton thread, combustion crucible, bomb, nist certified benzoic for calibration, any other accessories required for analysis of food samples.", gas chromatograph with ecd, tcd, fid with autosampler, "pesticide column (30 m x 0.250mm x 0.25µm (5ms (95% dimethyl-, 5% diphenyl-polysiloxane / 1ms (100% dimethyl polysiloxane or equivalent) 100 mm column for fatty acid profiling with main concern of trans fatty acid application, column for cholesterol application, stationary phase: 95% dimethyl-, 5% diphenyl-polysiloxane (30 m x 0.250mm x 0.25µm),", "vial sets (1, 2 ml, crimp type, amber and clear glass), vials (10, 20ml crimp type with cap & septa), 300/500 µl recovery vials, septa ptfe/silicone (for 1, 2 ml vials), septa ptfe/silicone (for 10, 20 ml headspace vials), ergonomic crimping tools for different vial types, ergonomic decapping tools for different vial types, head space vials 10,20 ml capacity, suitable syringes for quoted autosampler, suitable headspace syringe /valve/loop, quechers kits for pesticides and herbicides in following matrices:matrices with high fat, matrices with high water content, matrices with high pigmented, spe cartridges for water.", ultra performance liquid chromatography (uplc) with photodiode array (pda), fluorescence (fld) and refractive index detector (rid), sample vials with 1.5 ml or greater, stainless steel ultra sonic bath with the capacity of 5 l or more, with time setting (min) 1-30min or continuous operation with led and push button (should be ip 33 protection class) for sonication of spare parts as well as solvents, fittings, frits, ferules and tubing’s, tubing cutter, solvent bottles (1000 ml capacity), solvent filters (glass & ss both, compatible manual syringes -10 µl, 20 µl, 50 µl, standards for hplc calibration for pda, ri and fluorescence detector, consumables required for each detector must be provided., "hplc columns: one each ofc8 = 250 × 4.6 × 5μm c18 = 250 × 4.6 × 5μmcyano = 250 × 4.6 ×5μm. amino = 250 × 4.6 × 5μmphenyl = 250 × 4.6 ×5μm. silica = 250 × 4.6 × 5μm.all columns must be supplied with respective guard column and holder. ", uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate.", uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate.", ft-ir with atr & liquid cell, "• hydraulic press with kbr die and pellet holder• suitable mortar pestle (dia 5-6 cm)• suitable portable de humidifier to maintain 30- 60% rh• temperature and relative humidity digital indicator with calibration certificate from iso 17025 accredited lab.• ref
Tender For supply, installation, testing and commissioning of gaschromatography system - 10 units at different dairies of comfed as per technical specification of tender document under scheme npdd cum state plan 2024-25.
Tender For supply of gaschromatography spares d d - cic make gaschromatography model dhruva, temperature controller , cic make gaschromatography model dhruva, ssr 25amp dc to ac , cic make gaschromatography model dhruva, mol sieve 5a column , cic make gaschromatography model dhruva, heater coil , cic make gaschromatography model dhruva, tc-k sensor , cic make gaschromatography model dhruva, spares installation and commissioning charges , cic make gaschromatography model dhruva,tcd amplifier pcb
Tender For corrigendum : supply of gcms ms cost of equipment plus man power 7 years plus cmc 5 years plus excluding gst 18 perc , lcms ms cost of equipment plus man power 7 years plus cmc 5 years plus excluding gst 18 parc , icpms cost of equipment plus man power 7 years plus cmc 5 years plus excluding gst 18 perc , gc fid , hplc uv detector , hplc pda detector , uv spectro photometer , gas liquid chromatography , digital polarimeter , fourier transform infrared specrophotometer , highperformance thin layer chromatography system , dissolution apparatus
Tender For corrigendum : online tender for supply and installation of gaschromatography mass spectrometer with head space to dept. of biological control, king institute of preventive medicine and research, chennai