Get complete information related to latest Holiday Detector Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Holiday Detector Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Holiday Detector Tenders.
Tender For bid to ras supply of integrated zangli garrison surveillance system - high definition bullet camera for integrated solution , programmable ptz camera for integrated solution , high definition ip dome camera for integrated solution , high power poe switch , gigabit interface converter , networking switch , interconnect cable , network cable , communication cable , gpu for ai application , enterprise server , smart network video recorder , storage device , power conversion board , power feeding cables , high capacity power backup , security light white with accessories and mounting bracket , ac distribution panel , command and control system , video management system , motion and object detection licenses , gait detection licenses , visitor management system licenses , ip based pa system , sound setup , weather proof rack 9u with mount , camera protection cover incl accessories , 6 meter pole with camera mounts , installation and commissioning
Tender For corrigendum : (1) strengthening/protecting of power supply from surges by providing switching between redundancy and suitable measures for protection of s&t equipment from surges along with detection of low insulation case of communication media(2) provision of eld tracking device, fuse alarm system & various accessories for improving maintenance of signalling assets.
Tender For supply of material and labour for attending of breakdown in fire detection alarm system and fire fighting system at air wing arc sarsawa area. , material and labour for detection of nature of defect including carry out minor repairs, loose connection change of small length of wire as required size to make the machine equipment functional. , material and labour for opening of switch board panel board and refixing the same after necessary repair etc complete all as specified and directed. , material and labour for cleaning of detectors mcp hooter any type in any height as and when required with air blower for making all detection system healthy in any type , material and labour in repair for reprograming of existing fire alarm system installed at airwing arc sarsawa all as directed. , material and labour for loope checking changing of device location name and address of the room and preparing as build drawing all as specified and directed
Tender For rate contract for the procurement of consumables/nonconsumables for the department of hicp unit - office of hospital infection control and prevention unit, anti hcv rapid with test device having flow through technology, sensitivity 99%, specificity >99% (usfda/ who approved) (per box 50 test), hbsag rapid (should detect all the 11 subtype of hbsag. antigen sensitivity-0.1ng/ml. should have diagnostic sensitivity & specificity of >99%) usfda/ who approved kits only will be selected (per kit 25 test), anti hbs ab (quantitative antibody assay) with test device having flow through technology usfda/ who approved (per kit 10 test), chromogenic media for detection of screening for methicillin-resistant staphylococcus aureus (mrsa)(500 gms), the endotoxtin detection kit must have the follwoing items. each of the component of the kit must be suffcient in quantity to run 72 independent single sample. -->lal (limulus amoebocyte lysate) reagent-must have sensitivity of 0.125/0.06 eu/ml (24 vials)-->control standard endotoxin-e.coli endotoxin055:b5 (14 nos.)-->lal (limulus amoebocyte lysate ) reagent water100 ml/bottle (10 bottles)-->pyrogen free dilution tube13x100 mm (30/ pack) - (10 packs)-->pyrogen free assay tube10 x 75 mm (50/ pack) - (8 packs)-->pyrogen free tips20-200ul (100 tips/pack) - (10 packs)-->pyrogen free tips 200-1000ul (50 tips/pack) - (10 packs), mac conkey purple broth (difco, himedia, oxoid, merck, sigma aldrich) (500 gms), brilliant green bile broth (500gms), m-lauryl sulplate broth (hi-meda) (500gms), sterile cotton swabs (individually packed packing 100 swab each box contain), schott duran bottle (500 ml), durhams tube (1 pack of 1000 tube), toothpick (wooden) (pack 10nos. of 250 stick), white glass marking pencil (pack of 10 nos.), sodium dichloroisocyanurate (nadcc) tablets for spill management (2.5g per tablet)
Tender For corrigendum : e-bid for rate contract cum supply and empanelment of surgical and suture items - anti a blood grouping serum ip(anti a monoclonal serum) [225], anti b blood grouping serum ip(anti b mono clonal serum) [226], anti d(rh) blood grouping serum ip/anti d blood grouping serum ip [227], vdrl antigen (with +ve and -ve control) / rpr slide kit :- specification for rpr _rapid plasma regain) slide test for detection of regain antibodies in syphilis1. rapid plasma reagin test kit having non- treponemal cardiolipin antigen coated carbon particles used in the detection of regain antibodies in serum / plasma of suspected cases of syphilis by the flocculation reaction.2. the kit should be meant for qualitative and semi quantitative detection of regain antiboidies against the non-treponemal cardiolipin antigen.3. sensitivity & specificity should be 95% or more.4. positive & negative control serum should be provided with the kit for at least 10% of the tests in each kit.5. the kit should have shelf life of minimum 12 months or more at the time of delivery of consignment. the kit should be stored at 2 c - 8 c.6. adequate literature detailing the principle, components, methodologies, validity criteria. bio-safety, performance characteristics, storage conditions, limitation of assay, manufacture and expiry dates and methods of disposal should be provided with each kit.7. the test should be free from possible interferences with potentially cross reactive sera.8. all the test kits should be provided with necessary / required disposable accessories in sufficient quantity.9. the imported kit should have approval of the statutory authority in its country of origin . the imported kits should have been registered and licensed in india by the cdsco. (central drugs standard control organization), double blood bags with sagm (350ml)general specifications annexure- xvi and specification in annexure-xxiii, laproscopic knotless pga -pcl bidirectional taper point surgical suture self fixation device with autolock mechanism made up of pga -pcl bidirectional taper point 17 mm & 32cm, curved cutter stapler 40 mm linear cutter simultaneous cutting and stapling, aortic punch 4.5 length betwwen 6 to 7 midlength diamond edge sharp, dual cut edge for clean precise removal of aortic tissue, conical tip or round / eliptical tip for easy insertation by straight or button hole tech, should have long and short handle confirguaration, sterile packing, aortic punch 3.6 length betwwen 6 to 7 midlength diamond edge sharp, dual cut edge for clean precise removal of aortic tissue,conical tip or round / eliptical tip for easy insertation by straight or button hole tech, should have long and short handle confirguaration, sterile packing, biopsy gun with compatible co-axial needle 14g x 11cm to 20cm programmable automatic should have 20mm sample notch and thin wall cannula for larger core and echogenic making on both stylet tip and cannula for improved visibility during procedure. should have three programmable firing mode-automatic mode, delay mode and zero throw mode. should have two firing btton on surface of the gun, size 12g, 14g, 16g, 18g, 20g with length 11cm, 15cm, 20cm. should come with compatible coaxial packed with biopsy gun. usfda approved., programmable automatic biopsy gun with compatible co-axial needle size 18gx11cm or above should have 20mm sample notch and thin wall cannula for larger core and echogenic making on both stylet tip and cannula for improved visibility during procedure. should have three programmable firing mode-automatic mode, delay mode and zero throw mode. should have two firing btton on surface of the gun, size 12g, 14g, 16g, 18g, 20g with length 11cm, 15cm, 20cm. should come with compatible coaxial packed with biopsy gun. usfda approved. (size 18gx11cm or above), programmable automatic biopsy gun with compatible co-axial needle size 18gx15cm or above should have 20mm sample notch and thin wall cannula for larger core and