Get complete information related to latest Ht Power Cable Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ht Power Cable Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ht Power Cable Tenders.
Tender For under the capital s.i. head, in the electricity distribution division sitarganj, under 33/11 kv sub-station bara, replacement of old and deteriorated ab cable/weasel conductor at different locations by installation of new ab cable
Tender For corrigendum : supply of sf 11 kv ms dp structure 11kv 200a 3 ph supply as specified , sf 11 kv 200 amp gaob switch as specified , sf 11 kv 200 amp heavy duty dropout fuse set as specified , replacment of ligting arrestor 9 kv, 5 ka as specified , replacement of polymer disc insulator 11 kv as specified , replacement of polymer pin insulator 11 kv as specified , earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick as specified , pvd fixing 25mm x 25mm gi strip in 40 mm dia gi pipe , pvd fixing 25mm x 25mm gi strip on surface or recess , supply laying 3 core 95 sq mm xlpe htpowercable 11kv in rcc hume pipe as specified , supply making indoor cable end termination with heat shrinkable jointing kit for 95 sq mm cable , supply making straight through cable jointing with heat shrinkable jointing kit for 95 sq mm cable , re fixing of existing protection cover arrangeement with wire mesh ms angle structure etc , providing gi or ms wire mesh i.e. netting of weleded or woven gi or ms wires , supply fixing ms structure of suitable size
Tender For supply of xlpe htpowercables and pvc/xlpe insulated with pvc sheathed lt power/control cable for coal to chemical project, bcgcl lakhanpur, odissa.
Tender For supply of fabrication and construction of copper plate earthing details of electrodes and earth pit at akashvani rampur, uttar pradesh , interconnecting earth electrodes with providing, fabrication and fixing of 50mmx3mm copper strip at akashvani rampur, uttar pradesh , copper strip laying for extension of earthing system up to the xtr hall, ups and lt panel and terminating in bus bar by digging the soil and placing the copper strip along the trenches at air rampur , providing of 375x38x6mm copper bus bar with insulators and steel nut bolts and the fixing of 375x38x6mm copper bus bar is to be done to terminate the different earthing system at akashvani rampur. , providing and fixing of nomenclature sign marker for earth pits at akashvani rampur, uttar pradesh , digging of trenches of size 450mmx600mm total length 118mtr for 185 sq mm 3.5core and starting from electricity board energy meter to lt panel inside room and to respectively by digging the path , providing and grouting of 2 nos. of 3inch dia g.i pipes of different length on the cement concrete flooring and along the vertical walls. total length of both pipes is 27 mtr. , providing, grouting and fixing 2 nos. of 4inch dia g.i pipes along the ms stand of main mccb at energy meter. total length of both pipes is 14 mtr. , unwinding roll of 185 sq mm 3.5core al. cable from the cable drum and laying 2 length of this powercable through the trenches and through the gi pipes as laid down at akashvani rampur , reconstructing the cc flooring and repairing the area with cement concrete and stone aggregate mixer and finishing the surface, complete in all respect at akashvani rampur , providing and fixing of lt cable route marker made up of 2.5inch dia signage with 10mm x 2ft long ms rod at akashvani rampur, uttar pradesh fabrication and construction of copper plate earthing details ) /bid number : gem/2026/b/7445375 * /dated: 24-04-2026 & & / bid document 1 / 22
Tender For supply and termination of 20a, 240 v plug and socket with two pin industrial plug with socket confirming to iec 61439-3 suitable for flush mounting and surface mounting with cord end termination suitable for copper cable of conductor size 1.5 sqmm with cord-end termination in shop floor. all electrical works shall be carried out in accordance with the provision of indian electricity act 2003 and indian electricity rules 1956 amended to date and all the safety codes and procedures outlined in the safety codes shall be complied with general and safety requirement shall be governed by is 13947 (pt 1) 1993 and is:8623/1993, amended to date also termination of all cables shall be done with bimetallic terminal connector suitable for 2.5 dia aluminium tubular busbar for 20a copper palm copper cu etp cw 0041a and aluminium barrel aluminium al 99.5 cable connector temperature resilience, corrosion resistance size: 2.5 sqmm confirming to is: 5561-1970 with maximum temperature rise of 90 degree celsius. material shall be confirmed to designation a6 of is: 617-1959. breaking resistance for barrel 85 n/m sq m and for palm 225 n/m sq m with stretching a5% for barrel must be for palm 25. [ warranty period: 30 months after the date of delivery ]