Tender For design, engineering, manufacture, factory testing, supply, transportation, supervision of installation and commissioning of 22kv indoor vcb switchgear panel with 3 incomers, 2 bus couplers and 15 feeders for 220kv ss palakkad under transmission north
Tender For combined package of 1. work a-balance portion of providing additional 1x8mva, 66/11 kv transformer at 220/66/11 kv muguluvalli substation in chikkamagaluru taluk, chikkamagaluru district- work code-ce1047 2. work b- providing sas panel for 11kv bus coupler & sas integration for 11kv switchgear and other left out works of additional 8mva, 66/11kv transformer-2 at 220/66/11kv muguluvalli receiving station in chikkamagaluru taluk, chikkamagaluru district
Tender For supply and installation of lt panel at ozone switchgear, relocation of power supply distribution panel and laying of power supply cables to office, colony, canteen, pump house at yccp plant, yelahanka
Tender For corrigendum : self-priming non clog submersible pump with 25hp with 200cum/hour flow rate, 20m head, 1440 rpm pump , control panel with switchgear for 25hp submersible motor pump (any reputed make)
Tender For supply installation wiring & testing of programming controller variable frequency drive panel with powder coating siemens grey-7035 for mh-14 hp, ct-1.5 hp, lt-3hp, double speed for all motion with joystick with rrc master controller pendent operating with eot crane brake light arrangement along with dbr panel, along with protection switchgear consisting mcb of 6 amp, 18ka, sp/dp control transformer of 300va, 0-440-415-410/0-110 vac, relay with base, 3-ph line choke, dbr-2.75e,27.5kw break contactor along with suitable cables, terminations, etc. confirming to is 13408 or latest, supply for 5 ton eot crane at lower parel workshop. accepted make: yaskawa | siemens | schineder or equivalent [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : expression of interest (eoi) from any reputed manufacturers for budgetary quotations for supply of electrical equipment materials within the jurisdiction of dhbvnl on for destination basis- heat shrinkable termination kit for 11 kv xlpe cable (outdoor type) , 3cx50mm2 , 3cx95mm2 , 3cx120mm2 , 3cx185mm2 , 3cx300mm2 , 3cx400mm2 , scx630mm2 , heat shrinkable termination kit for 11 kv xlpe cable (indoor type) , 3cx50mm2 , 3cx95mm2 , 3cx120mm2 , 3cx185mm2 , 3cx300mm2 , 3cx400mm2 , scx630mm2 , 11 kv 3/c cable heat shrink type straight through joint of sizes , 3/cx50mm2 cable , 3/cx95mm2 cable , 3/cx120mm2 cable , 3/cx185mm2 cable , 3/cx300mm2 cable , 3/cx400mm2 cable , s/cx630mm2 cable , sleeve , sleeve, 11 kv insulated medium voltage line cover (mvlc) for acsr conductor (sleeve) suitable for size upto 100 mm2 as per nigam's technical specification /relevant iss and latest amendments thereof , un-armoured copper control cable , 2c x 4mm2 , 2c x 6mm2 , 3c x 4mm2 , 4c x 4mm2 , 6c x 4mm2 , 7c x 2.5mm2 , 10c x 2.5mm2 , lt xlpe armoured cable , lt xlpe mm2 cable un-armored 1c*300 , lt xlpe armoured 2c*16 mm2 cable , 33 kv ht tr-xlpe cable , 3/c 300mm2 , 3/cx400mm2 , 11 kv h.t. tr-xlpe cables , 11 kv 3c*400 mm2 tr-xlpe armoured cable(hdpe extruded cable duct) co- , 11 kv 3c*300 mm2 tr-xlpe armoured cable(hdpe extruded cable duct) co-, , 11 kv 3c*185 mm2 tr-xlpe armoured cable(hdpe co-extruded cable duct), , lt feeder panel and lt switchgear, , 400 amps acb, 4 pole, manual operated, fixed type with enclosure, , 200 amps mccb with enclosure, , 100 amps mccb with enclosure, , 7 way distribution feeder panel with 2 nos. mccbs, 4 pole, 3phase, 415 v, 400 amps for incoming and 5 nos. outgoing mccbs 4 pole, 3phase, 415 v, 100 amps rating type suitable for outdoor installation, in accordance with technical specification (type-d), , 33 kv rmus, , outdoor type 33 kv sf6 type extensible and motorized 5 way rmu (2lbs+3vcb) with fpi as per is (without frtu) with the provision of self-powered supply through 1 kva aux transformer (33/0.230 kv) as per ts, , outdoor type 33 kv sf6 type extensible and motorized 5 way, , outdoor type 33 kv sf6 type extensible and motorized 4 way rmu (2lbs+2vcb) with fpi as per is (without frtu) with the provision of self-powered supply through 1 kva aux transformer (33/0.230 kv) as per ts., , outdoor type 33 kv sf6 type extensible and motorized 4 way rmu (2lbs+2vcb) with fpi as per is (without frtu) as per ts., , outdoor type 33 kv sf6 type extensible and motorized 3 way rmu (2lbs+1vcb) with fpi as per is (without frtu) with the provision of self-powered supply through 1 kva aux transformer (33/0.230 kv) as per ts., , outdoor type 33 kv sf6 type extensible and motorized 3 way rmu (2lbs+1vcb) with fpi as per is (without frtu) as per ts., , outdoor type 33 kv sf6 type extensible and motorized 3 way rmu (1lbs+2vcb) with fpi as per is (without frtu) with the provision of self-powered supply through 1 kva aux transformer (33/0.230 kv) as per ts., , outdoor type 33 kv sf6 type extensible and motorized 3 way rmu (1lbs+2vcb) with fpi as per is (without frtu) as per ts., , outdoor type 33 kv sf6 type extensible and motorized 3 way rmu (3lbs) with fpi as per is (without frtu) with the provision of self-powered supply through 1 kva aux transformer (33/0.230 kv) as per ts., , outdoor type 33 kv sf6 type extensible and motorized 3 way rmu (3lbs) with fpi as per is (without frtu) as per ts., , outdoor type 33 kv sf6 type extensible and motorized 2 way rmu (2lbs) with fpi as per is (without frtu) with the provision, , of self-powered supply through 1 kva aux transformer (33/0.230 kv) as per ts., , outdoor type 33 kv sf6 type extensible and motorized 2 way rmu (2lbs) with fpi as per is (without frtu) as per ts., , outdoor type 33 kv sf6 type extensible and motorized 2 way rmu (2lbs) with fpi as per is (without frtu) as per ts. (both side extensible), , outdoor type 33 kv sf6 type extensible and motorized 2 way rmu (1lbs+1vcb)
Tender For corrigendum : : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cable end box, lt bus duct flange, off load tap changer on ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf control panel, auxiliary mcc panels, heat exchanger cooling system, raw water pump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of sp