Tender For strengthening of e&m equipments and allied works by painting as per uniform color code of pul prahaladpur & tekhand sps /installations under tughlakabad constituency ac-52 - supply items :- synthetic enamel dark grey paint dsr 2021: item code 0834, synthetic enamel royal blue paint dsr 2021: item code 0834, synthetic enamel light grey paint dsr 2021: item code 0834, synthetic enamel dark brown paint dsr 2021: item code 0834, synthetic enamel orange paint dsr 2021: item code 0834, synthetic enamel yellow paint dsr 2021: item code 0834, synthetic enamel black paint dsr 2021: item code 0834, red oxide zinc chromate primer dsr 2021: item code 4202, supply of kerosene oil dsr 2021: item code 0771, dhoti (worm out soft cotton cloth) dsr 2021: item code 5771, wire brush dsr 2021: item code 0364, soft brush dsr 2021: item code 0365, synthetic enamel reducer, job work :- arrangement of all required safety equipment (i.e. safety belts, ladders, safety helmets, safety shoes etc. as per required) and other logistics required to carry out the painting work at sps / installations., hire charges for painter dsr 2022: item code 1006, hire charges for helper/beldar dsr 2022: item code 1007, hiring of compressor with gun, rubber pipes & accessories for painting work on gear boxes, pumps, motors, starters, ms & ci pipes, ms chequered sheets etc dsr civil 2021: item code 0086
Tender For corrigendum : supply of painting of interior and exterior surface. , hygiene and cleaning , repair and maint of cctv cameras and biometric attendence equipment and it equipment , recharge of mobile and wifi , stationery and office supplies
Tender For carrying out the painting of corroded structural steel frames and various equipment of the wet ash system of ahp/stage-i/sdstps during the year 2025-26
Tender For armo 2024-25 works, sh: miscellaneous repair and service of pumps, painting and supply of day to day spares etc at hubballi airport, hubballi. - sh : 1 painting of lt panel, feeder pillers and light poles painting of electrical lt indoor,outdoor panels, fire hydrant boxes, exposed fire hydrant pipe line, diesel pipe line, exposed water, pumps, earth pit covers etc located in powerhouse, ac plant, switch rooms, fire pump room, pump room etc., with one or more coats of spray painting with synthatic enamel paint of approved brand and manufacturer to give an even shade, including cleaning of surface with detergent etc, of required color to give an even shade complete as required. painting of street light poles of 7 mtr height and approx with one or more coats of spray painting with synthatic enamel paint of approved brand and manufacturer to give an even shade, including cleaning of surface with detergent etc , of required color to give an even shade complete as required. painting of street light poles of 5 mtr height and approx with one or more coats of spray painting with synthatic enamel paint of approved brand and manufacturer to give an even shade, including cleaning of surface with detergent etc , of required color to give an even shade complete as required. painting of street light poles of 3ft height and approx with one or more coats of spray painting with synthatic enamel paint of approved brand and manufacturer to give an even shade, including cleaning of surface with detergent etc , of required color to give an even shade complete as required. sh:- 2 servicing of grundfose make hydro pneumatic water pumping system:- "servicing of hydro pneumatic water pumping system through oem or its authorized dealersdation as and when required basis including periodical, preventive and breakdown maintenance of the system, repair/ replacement of all defective parts and other associated accessories and electrical parts upto incoming power supply at different locations excluding supply of spare parts, complete as required to keep the equipment in serviceable condition as per aai special conditions and as per eic instructions. make: grundfose, model: hydro mpc 2 x cr 10-6" supplying of following spares suitable for existing hydro pneumatic water pumping system make: grundfose, model: hydro mpc 2 x cr 10-6 asper oem recommendations, as and when required basis at site complete as required asper aai special conditions and as per eic instructions. "1 gfs kit, chamber stack cr 10-6, (item code 96508408)" "gfs-spr-kit, shaft seal h qqegg, (item code 96511844)" "gfs io351b module digital/ analog, (item code 95042368)" "gfs spare,multi pump control(cu352) (item code 98288809)" pressure transmitter "gfs gt-d300 pn10 g1 1/4 v,(pressure tank) (item code 96528347)" sub head-3: supply of spares supply of 16a 3 pin plug top suitable for 230 volts,50 hz, ac system as per site requirement and aai approved make, sample.model :- anchor roma or equivalent. supply of 6a 3 pin plug top suitable for 230 volts,50 hz, ac system as per site requirement and aai approved make, sample.model :- anchor roma or equivalent. supply of 6a modular switch roma plus for operation on 230 volts,50 hz, ac system as per site requirement and aai approved make, sample.model :- roma plus or equivalent. supply of 6a modular socket for operation on 230 volts,50 hz, ac system as per site requirement and aai approved make, sample.model :- anchor roma or equivalent. supply of 6/16a modularl socket roma plus for operation on 230 volts,50 hz, ac system as per site requirement and aai approved make, sample.model :- anchor roma or equivalent. supply of 16a modular switch roma plus for operation on 230 volts,50 hz, ac system as per site requirement and aai approved make, sample.model :- anchor roma plus or equivalent. supply of 16a modular switch suitable for operation on 230 volts,50 hz, ac system as per site requirement and aai approved make, sample.model :- anchor roma or equivalent. "su
Tender For providing, designing, cutting, preparing surface and securely pasting high intensity retro reflective sheet for making danger sign and writing of feeder number and voltage grade 6.6kv poles painting of electrical equipment of all three sections and
Tender For custom bid for services - rpnc252027 support service for swing extruder vfd installation-shifting, foundation and installation of power transformer- 1. the power transformer is to be installed by construction of new transformer foundation, dismantling/modification of surface, providing chain link fencing on all other 4 sides, cleaning and refurbishment of bay area is in the scope of contractor only. all necessary manpower, tools & tackles, shifting machinery like hydra/crane etc shall be in the scope of contractor only. 2. shifting of power transformer of 7.2 mva onan from store to site, loading-unloading, erection, site storage are in scope of contractor. 3. the basic data sheet and ga drawing of the proposed transformer is attached in scope only. 4. the bidder if required must construct bay width, height and fire walls as per relevant is/iec/oisd standards and site conditions such that adequate clearances for maintenance shall be maintained. bidder to submit the plot plan of equipment layout of transformer layout along with the bid. the bidder shall carryout the site visit for assessment of the available installation space. the total length of the transformer bay should be such that the radiator can be accommodated on either side of transformer tank in the specified bay width. 5. all necessary earth pit provisions, & fire barriers/wall modifications, provision of new hvws water sprinklerbased firefighting system having suitable capacity for protection against the fire & explosion as per the design of supplied transformer and applicable standards & direction of eic. provision of all necessary fire protection system for transformers shall be in the scope of lstk contractor. 6. construction of oil drain facility of transformer as per is standard and hookup with existing burn oil pit. 7. the erection to be certified by contractor as per its recommended procedures which is to be submitted prior to erection. qap for erection and site commissioning shall also to be endorsed by contractor. 8. all kind of lifting, rigging work for loading-unloading, erection work including supply of hydra/ cranes, lifting rigging materials, manpower, tools and tackles as required are in scope of contractor. 9. all kind of skilled, semi-skilled, unskilled manpower as per itc of transformer requirement will be in the scope of contractor. 10. erection includes entire vacuum by proper capacity of vacuum pump, for not less than 48 hours, or more if required as per the instruction of engineer in charge. 11. first filling up of the transformer oil at site, its filtration, site testing oil sample, any refiltration required during final commissioning shall be in the scope of contractor including all tools, tackles and including oil filtration machines. oil may be supplied in drums, which should be properly sealed during transportation and storage. seal shall be verified and opened in front of iocl representative before filling in transformer. contractor should have enough storage capacity for handling oil. filling the oil from drums to the transformer through suitable capacity of high-quality filter machine and filtration of the same to get desired bdv &ppm as specified by engineer in charge and transformer manual. 12. contractor must replace all the gaskets by new ones if required by engineer in charge. 13. the contractor shall arrange nitrogen cylinder required at site for above work. 14. contractor must repaint the transformer tank with two coats of anti-rusting good finish ltbs grey shade 631 of is:5 by spray painting if required and as per the direction of engineer in charge..