Web Analytics Made Easy - StatCounter

Hydraulic Tank Repair Tenders

Get complete information related to latest Hydraulic Tank Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Hydraulic Tank Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Hydraulic Tank Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :39874750 Due date: 28 Apr, 202528 Apr, 2025 NA
Tender For supply, installation & commissioning of air compressors of 100 cfm with specifications: (i) r ated power: 10 hp minimum, (ii) free air delivery: 100 cfm or higher, (iii) air receiver tank: 300-500 liters, (iv) working pressure: 7-12 kg/cm2. make: elgi, atlas copco, or similar. [ warranty period: 30 months after the date of delivery ]

corporations/Associations/Others

CTN :39601259 Due date: 10 Apr, 202510 Apr, 2025 59.55 Lacs
Tender For corrigendum : supply, installation, testing and commissioning of compressor with air receiver at maneri dam

Co-operative

CTN :39689731 Due date: 01 Apr, 202501 Apr, 2025 32.0 Thousand
Tender For corrigendum : shifting work of nitrogen plant with screw compressor, air dryer and air receiver

Central Government/Public Sector

CTN :39513100 Due date: 04 Apr, 202504 Apr, 2025 NA
Location: Goa - Goa Goa - Goa
Tender For corrigendum : supply of cylinder head assembly for air receiver - design manufacture and supply test trial and commissioning of mono block type cylinder head assembly for high pressure compressed air cylinders of 106 ltrs for yard 1280 , design manufacture and supply test and trial and commissioning of mono block type cylinder head assembly for high pressure compressed air cylinders of 258 ltrs , obs , installation and commissioning spares , technical documentation as per sotr , design manufacture and supply test trial and commissioning of mono block type cylinder head assembly for high pressure compressed air cylinders of 106 ltrs for yard 1281 , design manufacture and supply test trial and commissioning of mono block type cylinder head assembly for high pressure compressed air cylinders of 106 ltrs for yard 1282 , design manufacture and supply test trial and commissioning of mono block type cylinder head assembly for high pressure compressed air cylinders of 106 ltrs for yard 1283 , design manufacture and supply test trial and commissioning of mono block type cylinder head assembly for high pressure compressed air cylinders of 106 ltrs for yard 1284 , design manufacture and supply test trial and commissioning of mono block type cylinder head assembly for high pressure compressed air cylinders of 106 ltrs for yard 1285 , design manufacture and supply test trial and commissioning of mono block type cylinder head assembly for high pressure compressed air cylinders of 106 ltrs for yard 1286

CTN :39844279 Due date: 03 Apr, 202503 Apr, 2025 NA
Tender For procurement of air receiver instrument

CTN :39341700 Due date: 05 Apr, 202505 Apr, 2025 NA
Tender For corrigendum : upgradation augmentation of shot blasting equipment and shot blasting room including replacement of three motor driven screw lp air compressor for upgradation augmentation of production shop floor (ab and ac bay) at ins eksila - upgradation/ augmentation of shot blasting equipment and shot blasting room including replacement lp air compressor as indicated in part-ii of rfp consists of the following:-, dismantling and degutting of lp air compressors along with all associated equipments and shifting work as specifiied in para 1(1.1)(a) part ii of rfp., lp air compressor, lp air compressor as specifiied in para 3 (3.1) part ii of rfp., dryer unit as specifiied in para 3 (3.1) part ii of rfp., air receiver tank (2000 liters) as specifiied in para 3 (3.1) part ii of rfp., air filter as specifiied in para 3 (3.1) part ii of rfp., acoustic canopy as specifiied in para 4 (4.1)(a) & (b) part ii of rfp., electric power distribution board/ control panel as specifiied in para 4 (4.1)(d) part ii of rfp., dismantling and degutting of shot blasting system along with all associated equipments and shifting work as specifiied in para 1.2 of part ii of rfp., shot blasting system, protection liner & rubber lining as specifiied in para 3(3.2) part ii of rfp., recovery unit as specifiied in para 3(3.2) part ii of rfp., dust collector & exhaust system as specifiied in para 3(3.2) part ii of rfp., shot blasting unit as specifiied in para 3(3.2) part ii of rfp., all other items associated with main eqipment which are mentioned in part ii of rfp [ex para 6(a) & 6(b) etc] part ii of rfp)., civil work for (refers to para 8 of part ii of rfp)., standard accessories (refers to para 9 of part ii of rfp), two years operation & maintenance spares (refers to para 10 of part ii of rfp), special maintenance tools and test equipment (refers to para 11 of part ii of rfp), technical literature / certificates / documentation (refers to para 13 of part ii of rfp), acceptance, testing, trials and commissioning charges (refers to para 14 of part ii of rfp), training (refers to para 16 of part ii of rfp), any other item such as transportation, insurance, freight, packing etc, notes:1. cost of item listed at sl 1 to 12 and 13 (if applicable) are to be quoted in the respective rows of the price bid sheet. 2. bidder not permitted to include cost of items listed at sl 6 to 13 with sl 1 to 5 as lumpsum amount 3. bidder required to mandatorily quote for sl 1 to 5 and 12 failing which bid shall be treated as non bonafide and liable for rejection.4. bidders are mandatorily to quote gst/ taxes as applicable against each serials, falling which bid shall be treated as non bonafide and liable for rejection.

Central Government/Public Sector

CTN :39814189 Due date: 15 Apr, 202515 Apr, 2025 NA
Location: Goa - Goa Goa - Goa
Tender For supply of asme u certified air receiver tank

CTN :39070516 Due date: 29 Mar, 202529 Mar, 2025 NA
Tender For corrigendum : supply of air receiver with head assembly_579609000001_10000569163041 , on board spare for air receiver_579609500001_10000569163041 , tools for air receiver_579609760001_10000569163041 , documentation for air receiver_579609810001_10000569163041 , instl and comm spares for air receiver_579609820001_10000569163041 , 1st submission of bd for air receiver_579609810002_10000569163041 , prservatn with consumble_air receiver_ser07555_1000056916 , service engineer for air receiver_ser07557_1000056916

State Government

CTN :39724434 Due date: 02 Apr, 202502 Apr, 2025 7.50 Lacs
Tender For supply of spare parts for annual repair and maintenance of air conditioning and refrigeration at sliet, longowal for the f/y 2025-26 - compressor, a) 3.5 t (for vertical type ac), reciprocating, b) 3.0 t (for split type ac), reciprocating, c) 2.0 t (for split & window ac), rotary, reciprocating, d) 1.5 t (for split & window ac), rotary, reciprocating, e) 1.0 t (ahr 13)/ kcj 513/ equivalent, f) kcl 0.75 t (2612)/ kcl 467/ equivalent, g) for refrigerator, (165-200 liters), (220-300 liters), (310-400 liters), h) 3.5 t (for vertical type ac), rotary, i) 3.0 t (for split type ac), rotary, j) compressor reciprocating kcl 0.75t/461, thermostat 240v of, a) split ac, b) window ac, c) water cooler, d) deep freezer (350,450 ltr.), e) refrigerator (165-330 ltr.), capacitor micro farad 220v, 50hz, a) 15, b) 25, c) 36, d) 45, e) 50, f) 60, g) 80, h) 100-125, starting relay, 230v, 50hz (for refrigerator / deep freezer) , rewinding of fan motor:, a) vertical ac (3.5 t) , b) outdoor unit of split ac , (1.5 t), (2 t), (3 t), c) window ac, (1 t), (1.5 t), (2 t), d) water cooler, (40 ltr.), (120-150 ltr.), (400 ltr.), e) deep freezer (500 ltr.), fan blade :, a) outdoor unit of split ac, (1.5 t), (2 t), (3 t), b) window ac, (1 t), (1.5 t), (2 t), c) water cooler (upto 150 liters), (400 ltr.), d) deep freezer (500 ltr.), copper dryer for refrigerator, mcb dp 32 amp 230v, capillary pipe , a) 64 no, b) 60 no, c) 54 no, d) 40 no, e) 031 no, f) 036 no, top plug :, a) 15 a, 230v flush type, b) 15 a industrial type with chain, faucet (water tap stainless steel) of water cooler , 4 core, 2.5 sqmm pvc insulated copper cable (fr) , pvc connection pipe 3/4" dia of length 2', ptmt ball cock complete with epoxy coated aluminum rod & hd ball of approved qty., a) 15mm, b) 25mm, fan motor of , a) vertical ac (3.5 t) , b) outdoor unit of split ac, (1.5 t), (2 t), (3 t), c) window ac, (1 t), (1.5 t), (2 t), d) water cooler, (40 ltr.), (120-150 ltr.), (400 ltr.), e) deep freezer (500 ltr.), copper pipe having wall thickness minimum 0.8mm, a) 1/8, b) 1/4, c) 3/8, d) 4/8, e) 5/8, f) 3/4, g) 1/2, remote of split/ window ac of , a) only transmitter unit, b) only receiver unit, fan capacitor micro-farad 230v, 50hz, a) 2.5, b) 4, c) 6, d) 10, e) 15, cooper welding rod, drain pipe of water cooler upto 150 ltrs., refrigerator fan motor, (165-200 liters), (220-300 liters), (310-400 liters), refrigerator lamp 230v, 50hz, refrigerator timer (defrost) 230v, 50hz, refrigerator bimetallic relay 230v, 50hz, refrigerator thermostat (frost free) 230v, 50hz, freezer unit of refrigerator, (165-200 liters), (220-300 liters), (310-400 liters), control pcb of window of make voltas, samsung, lg, blue star, whirlpool, lloyd, hitachi, carrier, (1 t), (1.5 t), (2 t), control pcb of split ac of make voltas, samsung, lg, blue star, whirlpool, lloyd, hitachi, carrier, (1 t), (1.5 t), (2 t), control pcb of vertical ac 3t, 3.5t of make blue star, midea, refrigerant gas, a) r-22, b) r-32, c) r-134a, d) r-410a, e) r410, f) r-600, r22 floron refrigerant gas, a) 450 gm, a) 900 gm, brazing gas (butane), "nitrile insulation sleeve (rubber tube)19 mm", "nitrile insulation sleeve (rubber tube)16 mm", brass forged flare nut, a) 1/4, b) 5/16, c) 3/8, d) 1/2, f) 5/8, g) 6/8, ms stand (with loading capacity of 120 kg) powder coated heavy duty (for outdoor unit of split ac), teflon tape, ac insulation cotton tape water proof, 14 meter length, width 48mm, air conditioner pipe wrapping black tape, 20 meter length, width 48mm, cable tie (100 pc pkt), compressor thimbles (heavy duty copper) 100 pc pkt, defrost heater for double door refrigerator , (165-200 liters), (220-300 liters), (310-400 liters), ms wall plug dia 10mm of length 75-120mm , a) pin type, b) bolt type (with two washer), ms wall plug dia 10mm of length 150mm pin type, copper thimble (50 pc pkt.) for, a) 2.5-4 sqmm , b) 4-6 sqmm, fan motor of double door refrigerator of capacity upto 400 ltr., pin valve for gas recharging/storing, relay

CTN :39721832 Due date: 08 Apr, 202508 Apr, 2025 NA
Tender For supply of screw compressor and associated piping - 100 hp screw compressor base mount aim 100 apm 7 having capacity 106 471 cfm at working pressure 7 kg per cm2 with vfd panel , refrigerated air dryer 500 cfm in and out connection size 2 and half inches , refrigerated air dryer filter pre filter 0.5mic 500 cfm , refrigerated air dryer filter micro filter 0.01mic 500 cfm , air dryer carbon filter 0.01 mic 500 cfm , air receiver tank of capacity 2000 litres with tank accessories
 Loading, Please wait...

Connect us via What's Up