Get complete information related to latest Hygiene Bag Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Hygiene Bag Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Hygiene Bag Tenders.
Tender For corrigendum : providing of custom bid for services - office renovation - invitation of bids for conversion of offices outside engineering barrier gate to storage compartments of oil & dope store at oap, mumbai-29 , "dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :of area 3 sq. metres and below " , "dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. " , "demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge. " , "providing and constructing brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to is: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand):with modular bricks " , providing and laying internal plaster in c.m.(1:4) 12 to 18 mm thick minimum, to brick masonry and/ or concrete surfaces in any location and at all levels including cleaning and watering the surfaces, filling out hollows or out of plumb surfaces with mortar and finishing to correct line and plumb etc. complete. , providing and applying rust inhabitation coal/system to exposed reinforcement bars and also new reinforcement bars after removing scales and rust complete as per specification. providing and applying bond coat to all exposed concrete surface and reinforcement bars prior to any treatment as per specification. providing and applying single component, fiber reinforced, thixotropic repair mortar of average thickness 50mm and above of "'basf" (master emaco 348 s) as manufacturer's specifications in specific layers, curing the surface after 72 hours of application with wet gunny bags etc. including carting away debris out of aiesl/airport premises. , "steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.thermo-mechanically treated bars of grade more. fe-500d. " , removing and dismantling existing rolling shutter with ms work in single section or built-up section including rsj, angles, tees, flats, plates, gusset plates, channels etc., including dismembering using gas cutting, cutting machine lowering the same from any level and stacking up to the lead of 50 m. all as directed by eic, etc., complete., including labour, tools , plants etc., complete. , "providing and fixing isi marked flush door shutters conforming to is :2202 (part i) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. "
Tender For corrigendum : e-bid for rate contract cum supply and empanelment of surgical and suture items - anti a blood grouping serum ip(anti a monoclonal serum) [225], anti b blood grouping serum ip(anti b mono clonal serum) [226], anti d(rh) blood grouping serum ip/anti d blood grouping serum ip [227], vdrl antigen (with +ve and -ve control) / rpr slide kit :- specification for rpr _rapid plasma regain) slide test for detection of regain antibodies in syphilis1. rapid plasma reagin test kit having non- treponemal cardiolipin antigen coated carbon particles used in the detection of regain antibodies in serum / plasma of suspected cases of syphilis by the flocculation reaction.2. the kit should be meant for qualitative and semi quantitative detection of regain antiboidies against the non-treponemal cardiolipin antigen.3. sensitivity & specificity should be 95% or more.4. positive & negative control serum should be provided with the kit for at least 10% of the tests in each kit.5. the kit should have shelf life of minimum 12 months or more at the time of delivery of consignment. the kit should be stored at 2 c - 8 c.6. adequate literature detailing the principle, components, methodologies, validity criteria. bio-safety, performance characteristics, storage conditions, limitation of assay, manufacture and expiry dates and methods of disposal should be provided with each kit.7. the test should be free from possible interferences with potentially cross reactive sera.8. all the test kits should be provided with necessary / required disposable accessories in sufficient quantity.9. the imported kit should have approval of the statutory authority in its country of origin . the imported kits should have been registered and licensed in india by the cdsco. (central drugs standard control organization), double blood bags with sagm (350ml)general specifications annexure- xvi and specification in annexure-xxiii, laproscopic knotless pga -pcl bidirectional taper point surgical suture self fixation device with autolock mechanism made up of pga -pcl bidirectional taper point 17 mm & 32cm, curved cutter stapler 40 mm linear cutter simultaneous cutting and stapling, aortic punch 4.5 length betwwen 6 to 7 midlength diamond edge sharp, dual cut edge for clean precise removal of aortic tissue, conical tip or round / eliptical tip for easy insertation by straight or button hole tech, should have long and short handle confirguaration, sterile packing, aortic punch 3.6 length betwwen 6 to 7 midlength diamond edge sharp, dual cut edge for clean precise removal of aortic tissue,conical tip or round / eliptical tip for easy insertation by straight or button hole tech, should have long and short handle confirguaration, sterile packing, biopsy gun with compatible co-axial needle 14g x 11cm to 20cm programmable automatic should have 20mm sample notch and thin wall cannula for larger core and echogenic making on both stylet tip and cannula for improved visibility during procedure. should have three programmable firing mode-automatic mode, delay mode and zero throw mode. should have two firing btton on surface of the gun, size 12g, 14g, 16g, 18g, 20g with length 11cm, 15cm, 20cm. should come with compatible coaxial packed with biopsy gun. usfda approved., programmable automatic biopsy gun with compatible co-axial needle size 18gx11cm or above should have 20mm sample notch and thin wall cannula for larger core and echogenic making on both stylet tip and cannula for improved visibility during procedure. should have three programmable firing mode-automatic mode, delay mode and zero throw mode. should have two firing btton on surface of the gun, size 12g, 14g, 16g, 18g, 20g with length 11cm, 15cm, 20cm. should come with compatible coaxial packed with biopsy gun. usfda approved. (size 18gx11cm or above), programmable automatic biopsy gun with compatible co-axial needle size 18gx15cm or above should have 20mm sample notch and thin wall cannula for larger core and