Web Analytics Made Easy - StatCounter

Ictpn Switch Tenders

Get complete information related to latest Ictpn Switch Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ictpn Switch Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ictpn Switch Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

corporations/Associations/Others

CTN :40288673 Due date: 06 Jun, 202506 Jun, 2025 NA
Tender For gravelling work at 132 kv switch yard of chandil substation and 33 kv s-y of jamshedpur substation under gomd-iii, dvc, jamshedpur

CTN :39384172 Due date: 14 May, 202514 May, 2025 NA
Tender For bid to ras corrigendum : supply of trans rectifier cum battery charger for ngopv yard 3037 to 3040 - trans-rectifier cum battery charger 4kw_782352530000_1000057394 - 1000057397_3037- 3040 , battery change over box_782352350101_1000057394 - 1000057397_3037- 3040 , hand change over switch 300a_782352350201_1000057394 - 1000057397_3037- 3040 , battery charging terminal box_782352530300_1000057394 - 1000057397_3037- 3040 , remote indication cum alarm panel_782352530500_1000057394 - 1000057397_3037- 3040 , hrc fuse with box_782352530600_1000057394 - 1000057397_3037-3040 , installation material_782352920300_1000057394 - 1000057397_3037-3040 , documentation for hard copy_782352990300_1000057394 - 1000057397_3037- 3040 , documentation of soft copy ietm level 4_782352990500_1000057394 - 1000057397_3037-3040 , obs for 2 years_782352950400_1000057394 - 1000057397_3037-3040 , service of engineers_ser10601_1000057394 - 1000057397_3037- 3040

corporations/Associations/Others

CTN :40299754 Due date: 11 Jun, 202511 Jun, 2025 NA
Tender For removal of scrap and garbage from dump yard near 33kv switch yard and different place of rihand hydro power station, pipri, sonebhadra

State Government

CTN :40278910 Due date: 15 May, 202515 May, 2025 1.35 Crore
Tender For urgent pipeline works in switch yard at pardi s/stn, dist. nagpur

State Government

CTN :40266371 Due date: 29 May, 202529 May, 2025 5.97 Lacs
Tender For maintaining the buildings, sweeping of roads and plucking of grass in switch yard area maintaining the plants and lawns at 400kv ss damarcharla in nalgonda district

State Government

CTN :40266369 Due date: 29 May, 202529 May, 2025 8.54 Lacs
Tender For maintaining the buildings, sweeping of roads and plucking of grass in switch yard area and maintaining the plants and lawns at 400kv ss choutuppal in yadadri-bhongir district for the period from 01.06.2025 to 31.03.2026 in omc, nalgonda

Central Government And Public Sector

CTN :40268466 Due date: 22 May, 202522 May, 2025 10.50 Lacs
Tender For providing of custom bid for services - supply, installation, testing and commissioning of 66kv current transformers (cts) along with accessories at 66kv switch yard at petronet mhb limited, hassan, including liaisoning work

CTN :40286631 Due date: 17 May, 202517 May, 2025 NA
Tender For purchase of switch yard dc 2 volt batteries

corporations/Associations/Others

CTN :39305768 Due date: 22 May, 202522 May, 2025 130.52 Crore
Tender For corrigendum : construction of underground power house building tail race tunnel switch yard and other associated work of power house site adits mat vertical pressure shaft and steel liner including branch tunnel and associated project roads of sbr hep

State Government

CTN :40071789 Due date: 02 Jun, 202502 Jun, 2025 NA
Tender For corrigendum : providing and installation of electrical accessories and allieds works at shaspur pwss, block-rampurhat-ii under bolpur mechanical division - supply, delivery at site and storage of wall mounted made of sheet steel fabricated 2 mm for load bearing & 1.6mm for non load bearing, indoor type, dust & vermin proof, lp-54 degree of protection, powder coated painted with rubber gaskets cover, front lockable hinged door with all switchgear and other items duly wired up and tested as per specification: incomer: (a) 100 amps, tpn mccb with adjustable ol, 36 ka, e/f, auto phase corrector & necessary accessories with suitable spd (i.e., ammeter, voltmeter, cts & switches), outgoing:- (b) 7.5 hp to 12.5 hp, tp star-delta starter with other accessories - 1 nos., (suitable size capacitor bank to improve pf from o.85 to 0.98) (c) yard lighting feeder with necessary accessories & time switch(digital) - 1 no. (d) 3phase actuator valve starter with other accessories -1 nos., (e) 2 hp ,3 ph,415v,clorinator feeder with necessary accessories & level controller-1 no., (f) 32a mccb fdr for iep/misc purpose-1no., (g) 32a mccb for in house light-1no.,(e) plc feeder with necessary accessories-1no.( all spare & components as per vendor list of phed), supply and delivery at site of 15 kva, 3phase, oil cooled type servo motor operated copper wound line voltage corrector conforming to is-9815 (pt.-1)- 1994 suitable for un-balanced input voltage with following specification including first filling oil as per is-335 where applicable.a) input voltage:- 3 phase, main supply may or may not be balanced with respect to phase to phase- 200v-500v phase to neutral-115v-290v.b) output voltage:-3 phase balanced output voltage. phase to phase- 400vor 415v 1%, phase to neutral- 230v-240v 1% (provision should be made to adjust the variation of output voltage per phase by a variable pot oil within 5% of output).c) line regulation:- out put voltage should remain well with 1% of set voltage (from minimum to maximum i.e. either 400v. or 415v. supply variation).d) load regulation : output voltage should remain neutral well within 1% of set voltage be ( from no load to full load ) i.e. either 400v. or 415v.e) correction speed:- better than 35 volt / second.f) efficiency:- better than 95% on full load.g) cut off limit (minimum &maximum ) by limit switch with audio & visual.h) metering indication:- by selector switch provision should be made available to measure input mains supply and output voltage other stabilizer for load current measurement an ammeter with selector switch should be available.i) lamp indication :- for input & output should be provided. ( 3 lamps per side ).j) mcb protection: for input side.k) load protection : hrc fuse on each output phase should be availablel) output over shoot:- beyond 210v to . 255v /phase in case of manual mode & voltage protection :auto mode operation.m) visual indication for under voltage & over voltage of output.n) manual mode:- up & down correction with o / p voltage over shoot protection. beyond 210 v-255 v. per phase.o) nature of cooling:- oil cooled system.p) electric current over load protection .q) circuit for delay output .r) input high voltage cut-off above 500 v.s) mode of operation:- auto/manual with a provision to restore the normal working of the unit standby operation should be available in case of any electronic failure in auto mode., installation of mcc panel along with main switch, changeover, busbar chamber, cut out etc. all electrical equipment within the pump house, drawing of cable properly on suitable size gi cable tray on wall / as per direction of eic as per layout & ie rules and all connection with supply necessary materials, cable etc to complete the work, making arrangement with supply & fixing of materials for taking power within the pump house from wbsedcl end as per direction of eic. [for ph no - i, ii & iii], installation of above
 Loading, Please wait...

Connect us via What's Up