Tender For supply of fqa lab mechanical for lara and talcher project d d -- magnetic particle inspection yoke type-02 nos, pie gauge for mpi-02 nos, radiography film densitometer-02 nos, uv lamp for fluorescent mpi and dpt-02 nos along with all accessories , group-5 - stay at site including lodging, boarding, local conveyence etc for supervision of erection and commissioning etc at site-02 days in talcher and 02 days in lara , group-5 - site visit - - should include travel expenses to-fro site, visa- insurance-if applicable, intermediary stay- for sup of e and c etc at site-01 visit in talcher and 01 visit in lara , group-6 - radiation survey meter-02 nos, personal digital dosimeter-04 nos, ultrasonic testing machine-conventional with probes and calibration blocks-02 nos with all accessories , group-6- stay at site including lodging, boarding, local conveyence etc for supervision of erection and commissioning etc at site-02 days in talcher and 02 days in lara , group-6 - site visit - should include travel expenses to-fro site, visa- insurance-if applicable, intermediary stay- for sup of e and c etc at site02 visit in talcher and 02 visit in lara , group-7- digital radiography-02 nos along with all accessories , group-7stay at site including lodging, boarding, local conveyence etc for supervision of erection and commissioning etc at site-04 days in talcher and 04 days in lara , group-7 - site visit - - should include travel expenses to-fro site, visainsurance-if applicable, intermediary stay- for sup of e and c etc at site-02 visit in talcher and 02 visit in lara , group8- optical microscope for replica interpretation,optical microscope and imageanalysissystem, stereo microscope with camera attachment-02 nos , group-8- stay at site including lodging, boarding, local conveyence etc for supervision of erection and commissioning etc at site-01 days in talcher and 01 days in lara , group-8- site visit should include travel expenses to-fro site, visa- insurance-if applicable, intermediary stay- for sup of e and c etc at site02 visit in talcher and 02 visit in lara , group-9- computed radiography-cr-scanner-02 nos-alongwith all accessories please refer price schedule , group-9- stay at site including lodging, boarding, local conveyence etc for supervision of erection and commissioning etc at site-04 days in talcher and 04 days in lara , group-9- site visit - - should include travel expenses to-fro site, visa- insurance-if applicable, intermediary stay- for sup of e and c etc at site-02 visit in talcher and 02 visit in lara , group-10- hardness tester rebound type-02 nos and hardness tester_uci method-02 nos-along with all accessories , group-10- stay at site including lodging, boarding, local conveyence etc for supervision of erection and commissioning etc at site-02 days in talcher and 02 days in lara , group-10- site visit - should include travel expenses to-fro site, visa- insurance-if applicable, intermediary stay- for sup of e and c etc at site01 visit in talcher and 01 visit in lara , group-11radiography film viewer-04 nos, radiography film samplesasme-02 nos , magnetic particles inspection-coil type with cable-02 nos, gaussmeter for mpi-02 nos, ni-cr panel for dpt-02 nos , group-11- stay at site including lodging, boarding, local conveyence etc for supervision of erection and commissioning etc at site-02 days in talcher and 02 days in lara , group-11- site visit - - should include travel expenses to-fro site, visa- insurance-if applicable, intermediary stay- for sup of e and c etc at site-01 visit in talcher and 01 visit in lara , group-12-pls refer item description and price schedule for details_holiday detector, stethoscope, vibration meter, comparator, roughness meter, noise meter, torque wrench etc , group-12- stay at //bid details2 / 46site including lodging, boarding, local conveyence etc for supervision of erection and commissioning etc at site-10 days in talcher and 10 days in lara , group-12- site visit - should include travel
Tender For purchase of equipments - purchase of equipment, 1. configuration design an 8-channel battery analyzer and its accessories 2. power 425 w3. voltage measuring range: 25 mv to 5 v, discharge minimum voltage: 0v or better, accuracy: 0.05% of fs4. current range: 0.5 ma to 6 a, accuracy: 0.05% of fs or better 5. power per channel output power: 30w, stability; +/- 0.1% of fs or better6. time rise time: 1ms (0~full range)7. frequency 10hz8. charge mode of operation: cc, cv, cccv, cp end conditions: voltage, current, relative time, capacity.9. discharge mode of operation: cc, cv, cp, cr, end conditions: voltage, current, test time, capacity, energy.10. pulse mode charge: cp mode, cc mode, discharge: cc mode, cp mode, min pulse width: 500ms, automated switch: automated switch from charge to discharge for each pulse end condition: voltage, relative time11. dcir support for the calculation of the point of the dcir12. cycle cycles: 1 65500 or better, steps: 250 or better, nested function: max three levels of loops13. protective function software, power-down data protection, user-defined safety (upper and lower) tolerance of current, voltage, and delay time14. channel features independent pairs of closed loops for the constant current source and constant-voltage source15. test reports and curves for analysis different types of curves created by software based on user definition. (voltage-time curve, current-time curve, capacity-voltage curve, loops times charge/discharge capacity curve, loops times charge/ discharge efficiency curve, etc.), data reports created by the software. comparison of the performance of the batteries tested in channels, both visually and statistically16. channels independent control17. ac input ac 220v 10% / 50hz 18. voltage and current testing sample 4 wire connecting 19. noise 85db20. data management mysql database21. communication means tcp/ip protocol22. data output excel, txt23. communication interface ethernet port24. number of channels per cabinet 825. accessories: 1. bi-potentiostat: electrochemical workstation or moduletechniques the system should be capable of running the rde / rrde technique simultaneously cyclic voltammetry (cv) with simulation/fitting programs linear sweep voltammetry (lsv) with stripping bulk electrolysis with coulometry (be) differential pulse voltammetry (dpv) with stripping normal pulse voltammetry (npv) with stripping tafel plot (tafel), potentiodynamic deactivation, pitting corrosion, corrosion rate, linear polarization, corrosion current, etc. multi-current steps (istep) amperometric i-t curve (i-t) lifetime testing open circuit potential time (ocpt) chrono amperometry (ca) chrono coulometry (cc) chronopotentiometry with current ramp (cpcr) potentiometric stripping analysis (psa) auxiliary signal measurement channel ir compensation external potential input galvanostatic charge discharge single/multiple cycle -chrono potentiometry (cp) with potential limits, polarity by potential or time, no. of cycles etc. voltage vs current density curves single or multiple potential steps with charge limits, single or multiple current steps, mixed voltage/current control using macro. i-v measurements, i max, pmax, fill factor, etc.impedance ac impedance (imp) 10 hz to 3mhz impedance time (impt) (mott-schottky) impedance potential (impe) impedance simulator with fitting open circuit potential time (ocpt)hardware specification of bi-potentiostat workstation/ module: potentiostat / galvanostat module, 2- or 3- or 4-electrode configuration maximum potential: 10v, maximum current: 250 ma peak or better and 2 amps with +/-25 volts for higher current measurement. compliance voltage: > 13v or better, potentiostat rise time: 300 ns or better galvanostat applied current range: 3na to +/- 100ma or better and upto 2 amps applied current accuracy: 20 pa or better input bias current: 1 pa or better cv and lsv scan rate: 0.000001 to 10,000 v/s. ca and cc pulse width: 0.0001 to 1000 sec imp frequency: 0.00001 t
Tender For purchase of sports exercise physiology lab equipments - multi-frequency body composition analyzer (pac), tetra-polar electrode method using 8 touch electrodes smf-bia technology, 15 impedance measurements using 3 different frequencies 5khz, 50khz, and 500khz must be equipped with data storage facility. touch screen color lcd screen display. voice guidance for test. measuring time:30 secs measuring weight maximum: 300 kg maximum height measurement: 220 cm measuring sites: whole body composition and segmental composition (arms, legs and truck) software: latest operating system with compatible and upgradable software. external interface via.rs232/usb/bluetooth/wi-fi compatible printer/inbuilt thermal printer must be supplied. must show high correlation with dexasecurity access code.