Get complete information related to latest Indicator Spares Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Indicator Spares Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Indicator Spares Tenders.
Tender For providing and installing automatic water chlorinator for mainataining minimum chlorination level along with operation and maintenance for five years at juc in the jurisdiction of aden/jrc
Tender For providing and installing automatic water chlorinator for maintaining minimum chlorination level along with operation and maintenance for five years at jrc in the jurisdiction of aden/jrc
Tender For providing and installing automatic water chlorinator for maintaining minimum chlorination level along with operatlon and malntenance for 5 years in the jurisdiction of aden/ldh.
Tender For supply of oil level sensor unit in winch reducer for arv wzt-3 , crane extension warning sensor in arv wzt -3 , automatic sbt cock changeover for tank t -72
Tender For construction of 38 nos type vi multi storeyed quarters ground plus 19 floors building for income tax department at nungambakkam chennai sh design and supply, installation, testing and commissioning of fully automatic 100 nos multi level puzzle type car parking system g plus 5 levels including comprehensive maintenance for 5 years on epc basis
Tender For supply, installation, testing & commissioning of floor mounted potable water purification sys tem with inbuilt drinking water cooler ro + uv, storage tank- inbuilt, storage tank capacity up to float val ve level- 120 ltr. capacity, material of water storage tank- stainless steel ss 304, conformity to standard f or ultraviolet system-is 14724 (latest) for water purification system with ultraviolet disinfection, output wa ter conforming standard-is 10500 (latest), power consumptions -775 watt, maximum input water tds allo w to the system- 2000 tds, operation mode- fully automatic with auto cut off, ro membrane rating- 80 gp d, type of compressor- rotary/reciprocating, cooling capacity: 40 ltr./hr., single phase 230/240 volt 50 hz , filtration water capacity - 80 ltr/hour, type of condenser-fin type/tube type, evaporator material- copper , water storage tank insulation- puf thermal insulation, number of cold water faucets- 1 no, number of no rmal water faucets- 1 no [ warranty period: 12 months after the date of delivery ]
Tender For special repairs replacement to e/m equipments and infrastructure at af stn jamnagar under ge (af) jamnagar no 1 - supply, installation and testing air cooled inverter based split ac unit with cooling functions and suitable to operate at ambient conditions of (22 deg c + 3 in cooling mode) air conditoner will have following conditons :- (a) refrigerant - r-410 a/r-32 (b) eer- 5 star rating (c) tonnage - 1.5 tr (d) indoor noise level - not more than 40 db (e) filter - as recommended by oem (f) remote - as recommended by oem including 02 nos remote bty (g) temp display, turbo mode and auto swing facility all specification will be as per is-1391 (part 2) and latest amendments as specified as directed by engineer-in-charge., supply, installation and testing air cooled inverter based split ac unit with cooling functions and suitable to operate at ambient conditions of (22 deg c + 3 in cooling mode) air conditoner will have following conditons :- (a) refrigerant - r-410a/r-32 (b) eer- 5 star rating (c) tonnage - 2 tr (d) indoor noise level - not more than 40 db (e) filter - as recommended by oem (f) remote - as recommended by oem including 02 nos remote bty (g) temp display, turbo mode and auto swing facility all specification will be as per is-1391 (part 2) and latest amendments as specified as directed by engineer-in-charge., note for item no 1 & 2 :- the cost of following items deemded to be included in quoted rate.(a) copper pipe duly insulated between indoor/outdoor unit upto lenght 10mtr for each unit (b) ms bracket for outdoor unit duly power coated with fixing arrangement.(c) making of hole in walls including civil work , sleeves and making good to the disturbed surface/wall.(d) testing and commissioning of the air conditioner to the entire satisfaction of engineer in charge(e) pvc round sheathed copper cable of suitable size for connecting indoor and outdoor unit upto supply point as per site requirement (f) taking down of existing ac and deposited to e/m store yard without any damage., supply and installation of voltage stabilzer for automatic operation single phase naturally air cooled indoor type and designed for input varioution between 180v to 250v without voltage stabilzed at 230v with accuracy of (+) 2.5% and capacity 4 kva as specified as directed by engineer-in-charge., supply and installed voltage stabilzer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 180v to 250v without voltage stabilzed at 230v with accuracy of (+) 2.5% and capacity 5 kva as specified as directed by engineer-in-charge., material & labour for sub main wiring with 2 run single core multistranded copper conductor cable, of size 4.0 sqmm each, pvc insulated, unsheathed, fire retardant, low smoke (frls) drawn through and including pvc casing capping with all necessary fitting and including one run of single core multistranded copper conductor cable, of size 4.00 sqmm, pvc insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete all as specified and as directed by engr-in-charge.note: 2 runs of main copper conductor, one run earth wire and pvc casing capping will be measured as one running meter for payment., s&f sheet metal enclosure , 20a single pole and neutral with a two pin and earth plug and socket complete in metal clad board (industrial type) with one single pole mcb 32 amp fixed properly on in concealed position all as specified as directed by engineer-in-charge., supply, installation, commissioning and testing in replacement of loop card having 254 devices of both detectors and modules in a single line circuit, slc supports both class a and class b wiring complete as specified and as directed by engineer-in-charge. make: ravel/honeywell/ceasefire industries pvt ltd, supply, installation, commissioning and testing in replacement of addressable smoke detector with base with binary coded address setting. dual leds for 360 visibil
Tender For purchase of biochemistry lab equipments - fully automatic biochemistry analyzerthroughput: 200 photometric tests/hour & 400 tests/hour with ise (optional)reagent positions: 50 cooled reagent positionssample type: whole blood, serum, plasma, urine, csf otherreading volume: 180 lsample volume: 2-70 l (adjustable in 0.1 l)reagent volume: 10-300 l (adjustable in 1 l)light source: halogen lampon board laundry: 6 stage cleaning, 2 stage drying with cuvette validation stepcalibration type: linear, non-linear, multipointprogrammable parameters: default system pack parameters + upto 10 user defined parametersdimensions and weight: ergonomic design and light weight., fully automatic hematology analyzerthroughput-up to 80 samples per hourdimensions and weight ergonomic design and light weighttest mode-cbc, cbc+diffdata storage capacity-up to 100 000 resultscommunication-lan port supports hl7 protocolpower requirement-a.c. 100-240 v, less than or equal to 300 va, 50/60 hzoperating temperature-15 to 30 degree celsiusoperating humidity-30-85%air pressure70-106 kpa, fully automatic immunoassay analyser random assay (hormone analyser)instrument name: immunoassay analyserusage/application-clinicalplate format-random assaydetection method-luminescenceparameters-blood alcohol contentautomation-fully automaticuser input-touchassays-diabetes, thyroid, cardiac, vit d, fully automatic electrolyte analyser-analysis time: 60 second per sample parameters- na , k , cl or ca2+no. of parameters 3 simultaneously90 luser inputs 5 colored touch screen displayelectrode type- sturdy electrode (facility to refill the solution)connectivity 2 usb port, rs232, lisdata storage- 10,000 patient results & 10,000 qc results for 3 levelssample identification- alphanumeric sample idqc management- tri-level quality control, l j plots of last 30 dayscalibration- 2 point calibration on every 4 hours1 point with every samplepower - 100 240 v, 50/60 hz (self adjusting)printer - inbuilt thermal printerroom temperature -15 30 c / 60 90 fhumidity- 85%dimensions and weight - ergonomic design and light weight, centrifuge machine along with 500 prp test tubes (double spin)parameter- neya-16 max speed (rpm)- 15000max rcf (g)- 21000max capacity (ml)- 4 x 175acceleration profiles- 10deceleration profiles- 10display-- multi-color lcdno of programmes- 10 (protected)timer- 30 sec to 99 min & continuous modeergonomic design and light weightsupply - 220v, 50 hz, 1 phasecan be used for extracting prp, autoclavekey features- high-pressure vessel: a high-pressure vessel designed to withstand high temperatures and pressures- temperature control: precise temperature control to ensure effective sterilization- timer and controls: easy-to-use timer and controls for convenient operation- safety features: multiple safety features, such as automatic shut-off and overheat protection, to prevent accidents and ensure safe operationconstruction and materials- stainless steel: a durable stainless steel construction to withstand high temperatures and pressures- insulation: high-quality insulation to ensure efficient heat retention and energy savings- door and seals: a secure door and seal system to prevent steam escape and ensure effective sterilizationperformance specifications- temperature range: 121 c to 134 c.- pressure range: upto 30 psi- cycle time: 15-60 minutes- sterilization capacity in liters or cubic feetsafety standards- compliance with regulations: compliance with relevant regulations, such as asme, fda, and iso standards- automatic safety devices: automatic safety devices, such as overheat protection and low-water cut off, to prevent accidents and ensure safe operation- interlocks: interlocks to prevent door opening during operation and ensure user safetyadditional features- data logging: optional data logging capabilities to track temperature, pressure, and cycle data- printed records: optional printed records of cycle data for documentation and quality control- validation and te