Web Analytics Made Easy - StatCounter

Industrial Plug Tenders

Get complete information related to latest Industrial Plug Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Industrial Plug Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Industrial Plug Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :38152158 Due date: 29 Nov, 202429 Nov, 2024 NA
Tender For supply of equipment of engineering department - electrical fault_finding simulator , characteristics of under_over voltage relay , harmonics analysis of non sinusoidal wave forms , characteristics of fuse and mcb testing kit , performance and testing of transformer protection system , radial and ring main distribution system , andersons bridge kit , kelvins double bridge kit , maxwells bridge kit , wheatstone bridge kit , measurement of 3-phase power with single watt meter and two cts , dual channel digital storage oscilloscope , 2mhz scientific function generator , automatic belt driven cone pulley shaping machine , mm3030minimill 3_4_5 axis cnc milling machine , digital wind data logger wireless anemometer , work station of 64 gb ram , brinell hardness testing machine , bending testing machine , strain measurement setup using rosette strain guage , pick and place robot arm 4-6 axes with pc set up , desktop pc intel core i7 12 gen 4gb graphic card , ups 600va 30 min backup , ups 1kva 1hr backup , ups 6kva 1hr backup , laser printer all in one , inkjet printer all in one , desktop pc intel core i5 12generation , ups 1.2kva , laser printer print_scan_copy bid number/ ( ( ) ): gem/2024/b/5569758 dated/* : 08-11-2024 bid document/ 2 1 / 31

Central Government/Public Sector

CTN :38043676 Due date: 15 Nov, 202415 Nov, 2024 1.20 Crore
Tender For corrigendum : repair and maintenance to 11 kv switchgear, power transformer, ht yard maint with connected items at 33/11 kv shekhawati grid and repair and maintenance of 11 kv switchgears, 11 kv cable distribution system with protection system with allied works at

State Government

CTN :37832034 Due date: 16 Nov, 202416 Nov, 2024 346.00 Crore
Tender For corrigendum : construction of diversion weir at the offtake point of the markandeya river at pachapur village to create a pool of water to divert the water from the river to the main pump house though the intake channel. supply, installation, testing and commissioning of pumping machinery of balance 03 nos out of (5w plus 1s) of vt of capacity 2830 hp to carry discharge of 0.914 cumecs at 187.8 m head along with electrical works for the main pump house. design, supply, erection, testing and commissioning of one power transformer of adequate capacity of 15 mva to meet the load requirement of main pump station for 110kv/6.6kv. construction of balance rising main for 4.752 km of pipe dia 1500 mm to 1200 mm in the main pump house from ch 18.830 km to ch 23.582 km at the delivery chamber-2 near mallapur village with necessary valves, chambers, crossings, thrust and anchor blocks. construction of bleeder of length 0.747 km, which conveys the discharge of 1.67 cumecs from the raising main at ch 19.377 km to delivery chamber-1 proposed adjacent to second pump house at hanabaratti village. construction of delivery chamber 1 adjacent to second pump house near hanabaratti tank. construction of second pump house and its allied works. supply, installation, testing and commissioning of pumping machinery with 3 nos (2w plus 1s) of vt of capacity 1500 hp to carry peak discharge of total 1.67 cumecs at 110 m head, along with electrical works for the second pump house. construction of pressurized bulk feeder no.4 of length 12.2 km, from the end of manifold system of second pump house to delivery chamber-3 at suthagatti village with necessary valves, chambers, crossings, thrust and anchor blocks, surge analysis & surge protection works. construction of delivery chamber - 2 at the end of rising main near mallapur village. construction of delivery chamber - 3 near suthagatti village, at the end of pressurized bulk feeder - 4 taking off from second pump house. supply, jointing, laying, testing and commissioning of pipe distribution network consisting of bulk feeder lines, mains, sub mains and sub feeders with ms/hdpe pipes of required pressure rating for conveying water under each blocks up to 20 ha sub chak, with necessary valves, chambers, crossings, thrust and anchor blocks. construction of security quarter, approach road and protection works all around the second pump house layout. construction of service road along the pipeline alignment for bulk feeders and main lines. transmission line from source sub stations to the second pump house with a switch yard with receiving tower,33kv vcb circuit breaker,33/6.6kv power transformers,6.6kv incomer ht pannel,110vdc battery and battery charger with dcdb,6.6kv 150kvar bus capacitor pannel,6.6/0.415kv auxiliary transformer,6.6kvht soft stater panel with capacitor,415v lt pcc pannel,6.6kvht electrical motors, lt load, other general items and safety accessories. operation and maintenance of the scheme for 5 years.

State Government

CTN :37968991 Due date: 19 Nov, 202419 Nov, 2024 134.89 Crore
Tender For survey,investigation,design, supply, erection,testing and commissioning of kiravatti tank filling scheme for filling up of mi/zp tanks located on right bank of bedti river in kiravatti and madanuru gram panchayats in yallapura taluka and tanks located on left bank of bedti river in gunjavati and mainalli gram panchayats in mundagod taluka by lifting water from bedti river on turn-key basis. phase-1 work, consisting of following components-construction of diversion weir, jack well cum pump house, vertical turbine pumps coupled to ht motors electrical panel, soft starter, capacitor. 33kv power transformers, 33/6.6 kv sub station, 33kv power line, 110kv/33kv transformer bay and 33 kv terminal bay, rising main, pressure distribution network for filling up of 50 tanks located on right bank through ms /hdpe pipes with installation of surge protection system, supply of spares and tools including operation and maintenance for five years after successful commissioning of entire system on turn-key basis for head works and right bank pipe distribution of kiravatti tank filling scheme phase-1

Central Government And Public Sector

CTN :38057097 Due date: 18 Nov, 202418 Nov, 2024 37.25 Lacs
Tender For supply of installation of damaged spare parts of plc and scada system - control transformer 1kva , motor protection cuircuit breaker, range- 51 -70a , breaker handle with knob, siemens 3vt series , panel door lock for power pack , ethrnet switch 5-port unmanaged, ports- 5 unmanged type aux. supply- 24vdc , smps din rail mounted 24v dc 10a, output- 24v dc, 10a din rail mounted type , star delta timer, 0 -60 sec , panel fan, 220v ac, size 6 inch , mcb 2.0 amp. single pole , mcb 4 a single pole , single pole mcb 6 amp , mcb 4 a double pole , dc mcb double pole 220 v dc 06 amp , tripple pole mcb 4a, c04 , mcb tripple pole, c curve, 6amp , relay 8-pin with base, 8-pin 24v dc with base , space heater, rating-500w 230v ac , pressure gauge, analog type, range- 0-500kgf per sq. cm , tank oil gauge, tank mounted direct measuring , directional solenoid valve, operating pressure- 315 kgf per sq. cm coil voltage-24v dc , gate position sensor for radial gate, e1-type range 0- 360 degree, analog output 4 - 20 ma , indication light - blue, indication lamp 22.5 mm 220v ac blue , differential pressure transmitter, two wire 4 -20 ma dc output with hart , level transmitter accuracy 5-10 mm , gate position indicator 5 digit 0.56 inch display 21 , voltmeter 0- 500v - analog , push button red with nc add on , ammeter, 0 -250a analog , indication light - red, indication lamp 22.5mm 220vac red , indication light - yellow, indication lamp 22.5mm 220v ac yellow , indication light - green, indication lamp 22.5mm 220v ac green , jumbo display size 6.5 inch usb ports 2.0 x 1, 3.0 x 1 , push button yellow with no add on, size 22.5 mm , push button blue with no add on, size 22.5 mm , push button green with no add on, size 22.5 mm , push button black with no add on, size 22.5 mm , emergency push button, size 22.5 mm , phase preventer relay system ac mode auto , utp cable cat-5e , cable 1.5 sqmm 4c flexible 100m bundle , 1024 tags and ddls of scada system , control terminal block, 2.5sq.mm , service engineer charges , traveling charges , freight charges

Central Government/Public Sector

CTN :38032010 Due date: 14 Nov, 202414 Nov, 2024 NA
Tender For supply of electrical items - cm23705040 teak wood switch board , cm23705150 wooden switch board , cm23716045 pvc junction box , cm23716062 pvc junction box , cm23716125 pvc bend , cm23716063 pvc bend , cm23716126 pvc flex conduit , cm23716052 pvc flex conduit , cm23734005 mica sheet , cm23734010 mica sheet , cm23734016 mica sheet , cm23734017 mica sheet , cm23734018 mica sheet , cm23734025 mica sheet , cm23734030 mica bakelite sheet , cm23602012 bulb bayonet cap , cm23602020 bulb bayonet cap , cm23763057 industrial socket , cm23763055 industrial plug , cm23757065 mcb box

CTN :37622400 Due date: 22 Nov, 202422 Nov, 2024 50.60 Crore
Tender For corrigendum : construction of 220 160 mva and 132 kv 50 mva gss at hindore rajiasar distt sriganganagar in rajasthan including survey supply of all smaterials erection including civil works testing and commissioning turnkey project - main material/ items, circuit breakers, 220 kv circuit breakers, 220kv circuit breakers (3 ph.) along with support structure, 2500 a, 50 ka, 132 kv circuit breakers, 132 kv circuit breakers (3 ph.) along with support structure, 1250 a, 40 ka, 33 kv circuit breakers, 33 kv circuit breakers (3 ph.) along with support structure, 1250 a, 25 ka, instrument transformers, capacitor voltage transformer, single-phase, 220 kv, 4400 pf cvt, single phase 132 kv , 4400 pf cvt, 33 kv potential transformer, 33/ 3 kv /110-110 3, current transformer (1-phase), 220 kv ct, 1000/1 a, 5c, 132 kv ct, 1000/1 a, 3c, 500/1 a, 3c, 33 kv ct, 1000/1 a, 4c, 500/1a, 2c, c&r panels & sas system (complete in all respect, refer section-v a, b, part-iii, volume-ii), new substation, control panel for 220 kv transformer (220 kv side) type: sas-thcb, relay panel for 220 kv transformer (for both hv & mv) type: sas-thrb, control panel for 220 kv feeder type: sas-fcb, relay panel for 220 kv feeder type: sas-frb, control panel for 220 kv bus coupler type: sas-bccb, relay panel for 220 kv bus coupler type: sas-bcrb, 220 kv busbar protection relay panel type: sas-bbrb, control panel for 220 kv transformer (132 kv side) type: sas-tlcb, relay panel for 220 kv transformer (132 kv side) type: sas-tlrb, control and relay panel for 1x 50/31.5/25 mva, 132/33 kv power transformer type sas-tcra, control panel for 132 kv feeder type sas-fca, relay panel for 132 kv feeder type sas-fra, control and relay panel for 132 kv bus-coupler type sas-bcra, control and protection panel for 33 kv feeder (i/c, o/g)/bus-coupler/ capacitor bank [for twin feeder/bay] type-fcrd, station hmi [industrial grade computer with 21"tft monitor as per specification requirements], station hmi (hot standby)[industrial grade computer with 21"tft monitor as per specification requirements], hmi view node[industrial grad computer with 21"tft monitor as per specification requirements], a3 size b&w laser printer, substation automation system network panel type sas-nw, modems (both sending and receiving end) for communication to rcc & sub sldc for plcc], data concentrator unit (dcu) at substation for ras mounted in suitable enclosure & fully wired, software: application as well as system software as per specification requirements for various hardware elements for meeting of functional requirement of the specification., substation auxiliary monitoring panel type sas-samp, other items:, fiber optic cables, connectors, ethernet cables, jack panels connectors, patch cords etc. for completing the substation lan as per specification requirements., transducers, sensors etc. (if not considered in the respective equipment/ items) for accumulating monitoring data as per the specification requirements for switchyards., surge arresters, 220 kv la, 132 kv la, 33 kv la, substation lt transformer, 33/ 0.433 kv, 250 kva lt transformer complete with all accessories, fittings, terminal connectors etc as specified filled with transformer oil, batteries & battery charger, batteries (sizing shall be as per requirement of technical specification), 220 v [min. 600 ah], 48 v [min. 600 ah], battery charger system, 220 v float and boost, 50 v float and boost, lighting system, outdoor lighting & other works, lighting fixture type fl-1, lighting fixture type fl-2, outdoor receptacle, type-rp, type-ro, substation premises lighting, lighting poles, type-l1, type-d1, street lighting type-sl-l1 for mounting on poles, street lighting type-sl-d1 for mounting on poles, sub-lighting boxes/panels type -slp at lighting mast and other loaction as designated complete with all controgears and accessories, items etc., lighting panel type acp-2 as per technical specification, lighting panel typ

CTN :37622467 Due date: 22 Nov, 202422 Nov, 2024 46.45 Crore
Tender For corrigendum : construction of 220/132 kv, 1x160 mva and 132/33 kv, 1x40/50 mva gss at 220 kv gss kolayat (distt-bikaner) in rajasthan including survey, supply of all equipments/materials, erection (including civil works), testing and commissioning (turnkey ) - main material/ items, circuit breakers, 220 kv circuit breakers, 220kv circuit breakers (3 ph.) along with support structure, 2500 a, 50 ka, 132 kv circuit breakers, 132 kv circuit breakers (3 ph.) along with support structure, 1250 a, 40 ka, 33 kv circuit breakers, 33 kv circuit breakers (3 ph.) along with support structure, 1600 a, 31.5 ka, instrument transformers, capacitor voltage transformer, single-phase, 220 kv, 4400 pf cvt, single phase 132 kv , 4400 pf cvt, 33 kv potential transformer, 33/ 3 kv /110-110 3, current transformer (1-phase), 220 kv ct, 1000/1 a, 5c, 132 kv ct, 1000/1 a, 3c, 500/1 a, 3c, 33 kv ct, 1000/1 a, 4c, 500/1a, 2c, c&r panels & sas system (complete in all respect, refer section-v a, b, part-iii, volume-ii), new substation, control panel for 220 kv transformer (220 kv side) type: sas-thcb, relay panel for 220 kv transformer (for both hv & mv) type: sas-thrb, control panel for 220 kv feeder type: sas-fcb, relay panel for 220 kv feeder type: sas-frb, control panel for 220 kv bus coupler type: sas-bccb, relay panel for 220 kv bus coupler type: sas-bcrb, 220 kv busbar protection relay panel type: sas-bbrb, control panel for 220 kv transformer (132 kv side) type: sas-tlcb, relay panel for 220 kv transformer (132 kv side) type: sas-tlrb, control and relay panel for 1x 40/50 mva, 132/33 kv power transformer type sas-tcra, control panel for 132 kv feeder type sas-fca, relay panel for 132 kv feeder type sas-fra, control and relay panel for 132 kv bus-coupler type sas-bcra, control and protection panel for 33 kv feeder (i/c, o/g)/bus-coupler/ capacitor bank [for twin feeder/bay] type-fcrd, station hmi [industrial grade computer with 21"tft monitor as per specification requirements], station hmi (hot standby)[industrial grade computer with 21"tft monitor as per specification requirements], hmi view node[industrial grad computer with 21"tft monitor as per specification requirements], a3 size b&w laser printer, substation automation system network panel type sas-nw, modems (both sending and receiving end) for communication to rcc & sub sldc for plcc], data concentrator unit (dcu) at substation for ras mounted in suitable enclosure & fully wired, software: application as well as system software as per specification requirements for various hardware elements for meeting of functional requirement of the specification., substation auxiliary monitoring panel type sas-samp, other items:, fiber optic cables, connectors, ethernet cables, jack panels connectors, patch cords etc. for completing the substation lan as per specification requirements., transducers, sensors etc. (if not considered in the respective equipment/ items) for accumulating monitoring data as per the specification requirements for switchyards., surge arresters, 220 kv la, 132 kv la, 33 kv la, substation lt transformer, 33/ 0.433 kv, 250 kva lt transformer complete with all accessories, fittings, terminal connectors etc as specified filled with transformer oil, batteries & battery charger, batteries (sizing shall be as per requirement of technical specification), 220 v [min. 600 ah], 48 v [min. 600 ah], battery charger system, 220 v float and boost, 50 v float and boost, lighting system, outdoor lighting & other works, lighting fixture type fl-1, lighting fixture type fl-2, outdoor receptacle, type-rp, type-ro, substation premises lighting, lighting poles, type-l1, type-d1, street lighting type-sl-l1 for mounting on poles, street lighting type-sl-d1 for mounting on poles, sub-lighting boxes/panels type -slp at lighting mast and other loaction as designated complete with all controgears and accessories, items etc., lighting panel type acp-2 as per technical specifica
 Loading, Please wait...

Connect us via What's Up