Get complete information related to latest Injection System Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Injection System Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Injection System Tenders.
Tender For supply installation and commissioning of nitrogen injectionsystem and fire protection system of 01 no 3point 15 mva 33kvor3point3 kv transformer installed at 33 kv substation under chitra colliery sp mines area
Tender For repair of gen set -repair of fuel injectionsystem of gen set , rewinding of alternator of gen set , repair of cyl head of gen set , repair of diode plate of gen set , repair of lubrication system of gen set
Tender For corrigendum : bmc for chp stg 1 firefighting system main plant stage 1 additional ac system plc and dry sorbent injectionsystem plc for stage i units
Tender For supplying of 33/6.6 kv, 6.3 mva, 3 phase, 50 hz, oil immersed c cooling, oltc, outdoor type, copper wound transformer of with connection on hv side & star connection on lv side with r effectively earthed (vector group-dyn11), with on load tapping hv winding for hv variation from +5% to 15% in 16 equal 7.15% impedance, continuously rated for full load with first filling and standard accessories including suitable cable box at lv si transformer for termination of xlpe cables etc. complete with certificate with load losses of 33kw (max) and no load losses kw (max) at 75 deg celsius (as per given in cbip manual) & effic not less than 99.50% at full load. polyamide material for bushing and supplying of 33/11 kv, 10 mva, 3 phase, 50 hz, oil immersed onan cooling, oltc, outdoor type, copper wound transformer of with delta connection on hv side & star connection on lv side with neutral effectively earthed (vector group-dyn11), with on load tapping's on hv winding for hv variation from +5% to 15% in 16 equal steps, 8.35% impedance, continuously rated for full load with first filling of oil and standard accessories including suitable cable box at lv side of transformer for termination of xlpe cables etc. complete with test certificate with load losses of 53kw (max) and no load losses of 7.2 kw (max) at 75 deg celsius (as per given in cbip manual) & efficiency not less than 99.50% at full load. polyamide material for bushing with certified nitrogen injectionsystem with sump pit, nitrogen cylinders pipeline (as per cea guidelines 2021 nitrogen injection fire prevention and extinguishing system)