Get complete information related to latest Instrument Panel Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Instrument Panel Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Instrument Panel Tenders.
Tender For corrigendum : providing and installation of electrical accessories and allieds works at shaspur pwss, block-rampurhat-ii under bolpur mechanical division - supply, delivery at site and storage of wall mounted made of sheet steel fabricated 2 mm for load bearing & 1.6mm for non load bearing, indoor type, dust & vermin proof, lp-54 degree of protection, powder coated painted with rubber gaskets cover, front lockable hinged door with all switchgear and other items duly wired up and tested as per specification: incomer: (a) 100 amps, tpn mccb with adjustable ol, 36 ka, e/f, auto phase corrector & necessary accessories with suitable spd (i.e., ammeter, voltmeter, cts & switches), outgoing:- (b) 7.5 hp to 12.5 hp, tp star-delta starter with other accessories - 1 nos., (suitable size capacitor bank to improve pf from o.85 to 0.98) (c) yard lighting feeder with necessary accessories & time switch(digital) - 1 no. (d) 3phase actuator valve starter with other accessories -1 nos., (e) 2 hp ,3 ph,415v,clorinator feeder with necessary accessories & level controller-1 no., (f) 32a mccb fdr for iep/misc purpose-1no., (g) 32a mccb for in house light-1no.,(e) plc feeder with necessary accessories-1no.( all spare & components as per vendor list of phed), supply and delivery at site of 15 kva, 3phase, oil cooled type servo motor operated copper wound line voltage corrector conforming to is-9815 (pt.-1)- 1994 suitable for un-balanced input voltage with following specification including first filling oil as per is-335 where applicable.a) input voltage:- 3 phase, main supply may or may not be balanced with respect to phase to phase- 200v-500v phase to neutral-115v-290v.b) output voltage:-3 phase balanced output voltage. phase to phase- 400vor 415v 1%, phase to neutral- 230v-240v 1% (provision should be made to adjust the variation of output voltage per phase by a variable pot oil within 5% of output).c) line regulation:- out put voltage should remain well with 1% of set voltage (from minimum to maximum i.e. either 400v. or 415v. supply variation).d) load regulation : output voltage should remain neutral well within 1% of set voltage be ( from no load to full load ) i.e. either 400v. or 415v.e) correction speed:- better than 35 volt / second.f) efficiency:- better than 95% on full load.g) cut off limit (minimum &maximum ) by limit switch with audio & visual.h) metering indication:- by selector switch provision should be made available to measure input mains supply and output voltage other stabilizer for load current measurement an ammeter with selector switch should be available.i) lamp indication :- for input & output should be provided. ( 3 lamps per side ).j) mcb protection: for input side.k) load protection : hrc fuse on each output phase should be availablel) output over shoot:- beyond 210v to . 255v /phase in case of manual mode & voltage protection :auto mode operation.m) visual indication for under voltage & over voltage of output.n) manual mode:- up & down correction with o / p voltage over shoot protection. beyond 210 v-255 v. per phase.o) nature of cooling:- oil cooled system.p) electric current over load protection .q) circuit for delay output .r) input high voltage cut-off above 500 v.s) mode of operation:- auto/manual with a provision to restore the normal working of the unit standby operation should be available in case of any electronic failure in auto mode., installation of mcc panel along with main switch, changeover, busbar chamber, cut out etc. all electrical equipment within the pump house, drawing of cable properly on suitable size gi cable tray on wall / as per direction of eic as per layout & ie rules and all connection with supply necessary materials, cable etc to complete the work, making arrangement with supply & fixing of materials for taking power within the pump house from wbsedcl end as per direction of eic. [for ph no - i, ii & iii], installation of above
Tender For corrigendum : supply, delivery and installation of pdb cum mcc panel and allieds works at sahapur pwss, block-dubrajpur under bolpur mechanical division, p.h.e.dte.
Tender For corrigendum : supply of l793319706001001 soot blower local mcc panel , l793319706001002 mandatory spares as per attached specifications , supervision for installation and commissioning
Tender For supply, installation, testing and commissioning of fire alarm panel and detectors in various buildings, control room, pumping shed, workshops, mcc room and dg room etc along with comprehensive annual maintenance contract for 5 years at wrpl kot pump station
Tender For corrigendum : supply of goods, tools & equipmentforan international standard itotin electrician tradeat iti vyara, gujarat, india - electrical machine trainer suitable for demonstrating the construction and functioning of different types of dc machines and ac machines (single phase and three phases). should be fitted with friction brake arrangement, dynamometer, and instrumentpanel and power supply unit., motor-generator (ac to dc) consisting of: squirrel cage induction motor with star-delta starter and directly coupled to dc shunt generator and switch board mounted with regulator, air breaker, ammeter, voltmeter, knife blade switches and fuses, set complete with case iron and plate, fixing bolts, foundation bolts and flexible coupling. induction motor rating: dc shunt generator rating: induction motor rating: dc shunt generator rating:, motor generator (dc to ac) set consisting of-shunt motor with starting compensator and switch directly coupled to ac generator with exciter and switch board mounted with regulator, breaker, ammeter, voltmeter frequency meter, knife blade switch and fuses etc. set complete with cast iron bed plate, fixing bolts, foundation bolts and flexible coupling. shunt motor rating: ac generator rating:, linear i.c. trainer, digital i.c. trainer, component of typical small hydro power, component of typical water mill, low voltage control and systems. with suitable tables, circuits, power supply, control units, software, hardware, wiring, switches ready to conduct the experiments by the student, residential and small business systems with suitable tables, circuits, power supply, control units, software, hardware, wiring, switches ready to conduct the experiments by the student, building control systems and automation with suitable tables, circuits, power supply, control units, software, hardware, wiring, switches ready to conduct the experiments by the student, industrial control system and automation with suitable tables, circuits, power supply, control units, software, hardware, wiring, switches ready to conduct the experiments by the student, solar system lab suitable tables, circuits, power supply, control units, software, hardware, wiring, switches ready to conduct the experiments by the student, training system predictive maintenance and condition monitoring of electric drives, electric vehicle motors and battery training & test bench, industrial electrical testing facility with circuits, power supply, control units, software, hardware, wiring, switches ready to conduct the testing by the student, ar-vr training set up., portable electric drill machine, pillar electric drill machine, outside micrometer, motorized bench grinder, rawl plug tool & bit, hydrometer, thermometer, soldering iron, copper bit soldering iron, de soldering gun, table vice, ohm meter; series type & shunt type, stock and dies conduit, multi meter (analog), digital multi meter, a.c. voltmeter, milli voltmeter, d.c. milliammeter, ammeter, a.c. ammeter, a.c. ammeter, kilo wattmeter, a.c. energy meter, power factor meter, frequency meter (analog + digital), tachometer with stopwatch, current transformer primary-, potential transformer, growler internal+ external, tong tester / clamp meter, megger, wheat stone bridge with galvanometer & battery 2 nos, earth tester
Tender For supply delivery and fittings of spares for 2 nos 90 kw star delta starter with allied works of mcc panel under mandalkuli water supply scheme under raipur block under bmd ,phe dte.