Tender For supply of current transformer as per drg. no. 24022240034, it. no. 37, rev-16. , current transformer (ct ratio 500/1a) as per drg. no. 24022240034, it. 38, rev. 16.
Tender For procurement of spares for mi-17v5 helicopter - overhaul manual of 17mt-7215-05, overhaul manual of 8mt-7102-10/apu, overhaul manual of 8mt-7202-10/rh & lh jn box/ohm, illustrated part catalogue of 8mt-7210-036/036-003/relay panel, overhaul manual of 8mt-7210-036/036-003/relay panel, overhaul manual of 8mt-7210-160/rh cb panel, illustrated part catalogue of 8mt-7210-20, overhaul manual of 8mt-7210-20, overhaul manual of 8mt-7210-230/rt console panel, overhaul manual of 8mt-7210-300/rt control panel, overhaul manual of 8mt-7210-340/central control panel, overhaul manual of 8mt-7210-440-003, overhaul manual of 8mt-7210-50/80sv/ lt & rt s/w panel, illustrated part catalogue of 8mt-7213-10/3, overhaul manual of 8mt-7213-10/3, illustrated part catalogue of acr-500 v/uhf txrx, overhaul manual of acr-500 v/uhf txrx, repair manual of acr-500 v/uhf txrx, illustrated part catalogue of d-20-2, overhaul manual of d-20-2, illustrated part catalogue of d-500tb, overhaul manual of d-500tb, illustrated part catalogue of epv-50 bt-2s, overhaul manual of epv-50 bt-2s, illustrated part catalogue of mfpu-8, maintenance manual mfpu-8, overhaul manual mfpu-8, repair manual mfpu-8, illustrated part catalogue of mp-100s-3s/ elect motor, overhaul manual mp-100s-3s/ elect motor, illustrated part catalogue of nat-301, repair manual nat-301, overhaul manual of pmk-21-3s, illustrated part catalogue of p-119-3f-125, overhaul manual of p-119-3f-125, illustrated part catalogue of p-507 cvr) illustrated part catalogue of p-507 c, overhaul manual of p-507 cvr, repair manual of p-507 cvr, illustrated part catalogue of pmk-21-3s, illustrated part catalogue of po-500a, overhaul manual po-500a, illustrated part catalogue of pt-125, overhaul manual of pt-125, overhaul manual of rio-3a/bis-4n, illustrated part catalogue of sgu-15, overhaul manual of sgu-15, repair manual of sgu-15, overhaul manual of so-121-vm, overhaul manual of sspfk-bi-2s, overhaul manual of ter-1m, illustrated part catalogue of tks/601 kod/dod, overhaul manual of tks/601 kod/dod, overhaul moverhaul manua of l20-09-989 sfsvanua of l20-09-989 sfsv, overhaul manual of 20-1009-813-10 feathing test sol valve, overhaul manual of 20-1009-953 ve-2t, overhaul manual of 20-1257-704/705, overhaul manual of 20-760-801-10 auto feather, overhaul manual of 682700-2pc reducer box, maintenance manual of akip-4501 distortion meter, operating manual of akip-4501 distortion meter, overhaul manual of at 8-3 auto transformer, overhaul manual of bchf-208 phase sequence unit, overhaul manual of di22a throttle, overhaul manual of f-100 filter, overhaul manual of f-70 filter, overhaul manual of k-50 condensor, overhaul manual koch-1a frequency cut off unit, overhaul manual of kul-150 control box, overhaul manual of kvps condensor, overhaul manual of mkt-4a electomagnet, overhaul manual of pul-1a control panel, overhaul manual of pus-36-71, overhaul manual of sbk cabin light, overhaul manual of ss-78 chip detector, overhaul manual of tf-1 current transformer, overhaul manual of tn 115/7.5 transformer, overhaul manual of tr 115/36 step down transformer, overhaul manual of tr-100 regulating transformer, overhaul manual of ts 1-2s transformer, overhaul manual of ts310s04b transformer, illustrated part catalogue of ark-9, repair manual of ark-9, illustrated part catalogue of ark-ud, circuit diagram of gr2.087.223-01ps, illustrated part catalogue of gr2.087.223-01ps, maintainance manual of gr2.087.223-01ps, circuit diagram of gr2.087.224-06, maintainance manual of gr2.087.224-06, illustrated part catalogue of ri-65, techincal description, ipc & repair manual of rv-3m, maintenance manual gui-301.034 rf.110.42.00 of rv-3m, oh manual of spu-, illustrated part catalogue of yadro-1a, oh manual of yadro-1a
Tender For supply of electrical and electronics laboratory setup - rlc resonance trainer kit series and parallel resonance, kit consists of voltmeter and frequency counter, inbuilt signal generator, experiments can be performed with or without oscilloscope inbuilt power supply, maximum power transfer theorem trainer kit maximum power transferred from a source to a load when the load resistance is made equal to the internal resistance of a source. inbuilt fixed dc regulated power supplies : 12vdc, meters, ammeter & voltmeter, required components provided, circuit diagram printed on front panel & all important test points are brought out on front panel power requirement : 230 vac, clamp on meter suitable for min 300 a ac/dc current measurement range: 0.2 to 300 a, accuracy 1.5% ac voltage: mv to 1000 vac, accuracy: 0.75% dc voltage: 30mv to 1000 vdc, accuracy: 0.5% resistance: upto 30 mohm, accuracy: 0.5% capacitance 1 nf to 30 micro f, accuracy: 1% frequency upto 100 khz, accuracy: 0.5% auto hold, max/min, auto/manual, diode, ip20 protection., digital meter: portable table top type, with cabinet and stand, terminals brought out for connections, range: voltmeter:0-750v ac 0-500 vdc, ammeter:0-20a ac 0-20a dc 2 nos each range, electronic energy meter( single phase) 240vac, 20aac, electronic energymeter( three phase) 400 vac, 30 aac, digital multimeter ¾ digit , true rms ac voltage range : 1 mv to 1000v, accuracy < 1% dc voltage range : 10 mv - 1000 v, accuracy < 0.5% ac current range : 1 ma-10a, accuracy < 2%, dc current range 0.01 ma-10a, accuracy < 1.5%, resistance: 100 mohm-60 mohms, accuracy < 0.5% input impedance: 10mohm capacitance: 1 nf – 60 mf, accuracy: < 5%, frequency: 0.01 hz – 10 khz, accuracy < 0.1% duty cycle, temperature and diode test, lcd display with auto / manual range , included accessories: test leads, rubber holster, temperature probe, battery charger 12 / 24v dc, 15 a, digital power factor meter, portable bench top type, with cabinet and stand, terminals brought out for connections, range: single phase, 220v ac, 5a, digital frequency meter, portable bench top type, with cabinet and stand, terminals brought out for connections, range: 45-55 hz, digital wattmeter, portable bench top type, with cabinet and stand, terminals brought out for connections, range: 220v, 5a ac single phase (2 nos) 400 v, 5a ac, three phase (2 nos), single phase half wave, full wave , fully controlled bridge rectifier / converter design to study to controlled rectifier & observe wave form on cro. meters provided of suitable range, in built power supply. load resistance, controls for phase angle. circuit diagram printed, & test points brought out on front panel. power requirement: 230 vac +10%, 50hz. supplied with patch chords & instruction manual, ups trainer kit input range: 170 to 270 v, ac output (input present): 195 to 250 v capacity: 200 w battery: 12 v / 7 ah, maintenance free, test points for experimentation purpose. panels: input / output / battery / transformer / avr / charger /inverter study of charger study of changeover logic study and working of ups, smps trainer kit input : 110- 230v, output : 12v dc, switching transformer, scr commuation trainer kit two dc regulated power supplies 0-30vdc/150ma & 0-1 vdc/150ma, three meters for voltage & current measurement , scr 2p4m mounted behind the panel, connections of supplies, meters & scr brought out at 4mm sockets., characteristics trainer kit for scr,diac,triac, ujt,igbt instrument comprises of three dc regulated power supplies 0-15 vdc/150ma, 0-50 vdc/150ma & 0-2.5 vdc/150ma, four round dual range meters for voltage & current measurement,ujt, scr, diac, triac & their supportive components mounted behind the panel, connections of supplies, meters & components brought out at 4mm sockets., kit for speed control of dc motor using microcontroller eters (digital) :0-200v dc, 0-500ma dc instrument provided with 1/12 hp dc motor, on board phase a
Tender For supply of current transformers transducers energymeters - current transformer 100 by 1a , current transducer current i p 1 amp , current transducer current i p 5 amp , current transformer 50 by 1a , cts mesuring ratio 125by1a 10va cl 1 , 3 ph. 4 wire multifunction energy meter