Tender For supply ofmagnetic base drill machine one thousand two hundred - magnetic base drill machine one thousand two hundred watt , oil seal kit for rotory barrel pump , pipe length ten meter , pipe length two meter , hand drill machine size one to twelve mm boss , carbon steel hacksaw blade double side size one into twelve inch taparia , steel twisted wire cup brush size three inch taparia
Tender For supply of materials for the schemes pertaining to kamrup rural w.r. division under pdna-2022. package 2 - construction and supply of wire -netting box of size 1.50 m 1.50 m 0.45 m made with mechanically woven, double twisted, hexagonal shaped wire mesh with wire made of low carbon, high ductile ms wire with heavy class of galvanization with an additional layer of pvc coating with mesh type of 10 12 as per en 10223 & astm a975, mesh wire of 2.70 mm (i.d) /3.70 mm (od) tensile strength of 450-500/mm2, edge wire selvedge around it at least 2.5 times, lacing wire (zinc pvc coated) of 2.20 mm (i.d)/3.20 mm (od), vc coating thickness of 0.50 mm nominal, 0.38 mm minimum, mesh opening size 150 mm 150 mm and with average weight per unit being 12 kg with additional 3% of the weight of box for lacing wire supplied separately, supporting the facing of the box with zinc coated steel wire of required length as directed, complying with astm and european norms.
Tender For e.i for setting up of work station system in the audit branch of administrative office in p.u campus, sector-14, chandigarh - wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls/hffr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. frls/hffr pvc insulated copper conductor single core cable etc. as required (dsr 1.8), group c (dsr 1.8.3), rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls/hffr pvc insulated copper conductor single core cable and 1.5 sq.mm frls/hffr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required (dsr 1.15), group c (dsr 1.15.3), supplying and drawing following sizes of frls/hffr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required (dsr 1.17), 3 x 2.5 sq. mm (dsr 1.17.12), 3 x 4 sq. mm (dsr 1.17.21), supplying and drawing following sizes of frls/hffr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required (dsr 1.21), 25mm (dsr 1.21.2), supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required (dsr 1.22), 75 mm x 75 mm x 60 mm deep (dsr 1.22.1), supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required (dsr 1.24), 5/6 a switch (dsr 1.24.1), 3 pin 5/6 a socket outlet (dsr 1.24.4), supplying and fixing following modular base & cover plate on existing modular metal boxes etc. as required. (dsr 1.28), 3 module (dsr 1.28.2), 6 module (dsr 1.28.4), 8 module (dsr 1.28.5), supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 a modular socket outlet and 5/6 a modular switch, connections etc. as required (dsr 1.31), supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 a modular socket outlet and 15/16 a modular switch, connections etc. as required (dsr 1.32), supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (dsr 2.4), 4 way (4 + 12), double door (dsr 2.4.1), supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required.(dsr 2.10), single pole (dsr 2.10.1), supplying and fixing dp sheet steel enclosure on surface/ recess along with 25/32 a 240 v "c" curve dp mcb complete with connections, testing and commissioning etc. as required. (dsr 2.16, providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. (dsr 5.18), supplying, drawing, installation, testing and commissioning of cat6a utp 4 pair, 23 awg solid copper cable in existing conduit/ on surface, u/ftp, lszh, non-plenum, horizontal (solid) cable suitable for high speed data networking application supporting upto 10gbps over a 100 meter channel. the 4 unshielded twisted pairs (utp) cable with color coded insulation for easy indentification should have flame properties i.e. flammability test - iec 60332-1, smoke density - iec 61034, lszh standards compliance: ansi/tia- 568 c.2, iso/iec 11801
Tender For tender for supply of deisgn engineering and supply of electrical instrumentation and civil works : : - design and engineering of imcc panel 2 nos and vfds , design and engineering of apfc and hvac , design and engineering of apfc and field instruments , design and engineering of cables and termination , design and engineering of earthing of imcc , field equipments and soil testing , design and engineering of civil buildings and structure foundations , design and engineering of imcc building with earthing system , design and engineering of structural works for cable laying for both incoming and outgoing cables , design and engineering of lighting system of imcc building , equipment locations at ccr ground floor and along the structural path for cable route , supply of imcc panels , vfd panels , supply of apfc panels , hvac system , supply of mldb lighting distribution boards , lighting material including db , light fittings , and all related accessories or wiring material etc , supply of field instruments and necessary piping materials as required , supply of plc , supply lt cables and other related accessories for electrical , termination material and other instrumentationcables as required , supply of cable trays for electrical and instrumentation , supply of all earthing material as per is 3043 for imcc and connection to earth pits for motors , panels etc , supply of fire detection and alarm system for building and cable alley area along with integration and display at fire station/existing control centre , erection , testing , commissioning , and handover of equipments of imcc panels and vfd panels , erection , testing , commissioning , and handover of equipments of apfc panels and hvac system , erection , testing , commissioning , and handover of equipments of lighting system as per above supply , erection , testing , commissioning of earthing system , erection , testing , commissioning of field instruments and necessary piping materials etc as required , erection , testing , commissioning and handover of plc , erection , laying , testing and commissioning of lt cables ( cable terminations wherever required along with necessary accessories is in the scope of the contractor) for electrical and instrumentation , erection , testing and commissioning of cable trays for electrical and instrumentation , erection , testing and commissioning of fire detection and alarm system for building and cable alley area along with integration and display at fire station/existing control centre , substructure excavation , foundation works (footings , columns up to plinth level) , dpc (damp proof course) , and backfilling. , superstructure columns , beams , slabs , brickwork/masonry for all floors above plinth level , and formwork up to ground floor , finishes plastering , flooring (tiles , marble) , painting , wall cladding , and other interior/exterior finishes , plumbing works , fixing of doors up to ground floor. , superstructure columns , beams , slabs , brickwork or masonry for all floors above plinth level , and formwork for subsequent floors as per approved design , finishes plastering , flooring (tiles , marble) , painting , wall cladding , and other interior/exterior finishes , plumbing works , fixing of doors for subsequent floors as per approved design , supply and erection of structural works for cable laying for both incoming and outgoing cables
Tender For supply of ethernate cables c c---item 10 , item 20 , item 40 , item 50 , item 60 , item 70 ethernet cable,utp,cat-6 (1) conductor: bare copper massive wire awg 24/1 (0.51 mm dia), (2)insulation polyolefin dia 1.0 mm (3) pair twisting: each two cores twisted to pairs: whbu/bu, whor/or, whgn/gn,whbn/bn, (4) cable lay up:four pairs stranded in one layer over central profile, (5) jacket:frnc halogen free, flame-retardant, grey ral 7035,6.5 0.3 mm dia,jacket with printing at regular intervals, (6) rated voltage 250 v,(7) loop conductor resistance at 20 c 190 /km, (8)insulation resistance at 20 c 5000 m , (9) mutual capacitance at 1khz is 50 nf/km, (10) impedance at 1mhz to 100mhz is 100 15 , (11)attenuation at 1 mhz is 2.1 db/100m, (12) maximum bending radius for fixed installation is 10 x d (outer diameter), (13) temperature range for fixed installation is up to +70 c, (14) fire performance: the cable shall be flame retardant type confirming to iec 60332-3 cat. c or ul type cm., 4 core compensating for pt- pt.rh10% thermocouple, conductor:multistranded insulation:non-flamable,heat and moisture resistant,positive core insulation of double sintered teflon having 0.05 mm thickness, then double fibre glass impregnated with silicon varnish having 50 micron thickness, then special flexible heat resistant silicon rubber having thickness of 0.80 mm to withstand heat moisture, negative core insulation of double sintered teflon having 0.50 mm thickness, then double fibre glass impregnated with silicon and moisture, overall asbestos braiding with polished yarn having ) /bid number : gem/2025/b/6991125 * /dated: 11-12-2025 & & / bid document 1 / 19