Get complete information related to latest Instrumentation Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Instrumentation Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Instrumentation Tenders.
Tender For corrigendum : for "carrying out instrumentation works" on sub-contract basis in connection with composite works for pdh unit for gail usar pdh-pp project at usar, alibag, raigad, maharashtra.
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - surendranagar pumping sttaion,gsecl; work of instrumentation maintenance; as per atc
Tender For supply of various lab equipments items for govt. pg college guna district guna (m.p.) - supply of various lab equipments items for govt. p g college guna district guna (m.p.), waterand soil testing analysis kit (digital) : range ph 0 to 14.00 resolution ph 0.01 accuracy ph 0.01 1 digit temp. comp. 0 to 100 deg. c., water bath (06holes) : 6 hole8 ltrs., waterbath(12holes) :12 hole 20 ltrs., water distillation apparatus(single distillation unit 2 litre/hour) : single distillation 5 litres, analytical balance : least cosunt 0.0002g, analytical weight box : 1-100g, fractional weight box : 1-500mg, physical balance : 250gm accuracy 0.1g, digital balance : least count 1mg, single pandigital balance : 0.1mg 200g, digital photoelectric colorimeter : 8 filter,1 ml, digital potentiometer : with hot plate and electrodes, digital conductometer : with cell 1cc and 0.1cc, d.o. meter : polarographic do range: typically 0 to 90 mg/l (milligrams per liter) or 0 to 600% saturation.rdo (optical) do range: usually 0 to 50 mg/l or 0 to 500% saturation., digital naphelo/turbidity meter : digital turbidity cum nephelometer range:-, 200,1000 ntu/jtu resolution:- 0.01 ntu/jtu accuracy:- 3% fs, 1digit display:- 3 digit 7-segment led light source:- ir led detector:- photodiode sample system:- 60 x 25mm clear glass test tubes power:- 230 v 10% ac, 50 hz accessories:- test tube set of 2, operation manual, dust cover, polarimeter half shade : the specific rotation ( ) is a physical property defined as the optical rotation at a path length of 1 dm, a concentration of 10 g/l, a temperature (usually 20 c), and a light wavelength (usually sodium d line at 589.3 nm), melting point apparatus :melting-point measurement range: room temperature - 400 c setting rate of the starting temp. : 50 c~400 c 5 min; 400 c~50 c 7 min minimum digital display: 0.1 c size of the capillary: 1.4mm (outside diameter) 1.0mm (inside diameter), 90mm equipped with color camera and color monitor to observe melting point with ease validation program for standard samples 8 operator names can be storedgraphic lcd display to display all test parameters & test instructions, digital melting point apparatus :melting point measurement range : ambient to 300 deg c starting melting point temperature : settable from 50 to 300 deg c heating time : 3 minutes (up to 300deg c) cooling time : 5 minutes (from 300 deg c) accuracy : +/ 0.5 deg up to 200 +/ 0.8 deg from 200 to 300 temperature display resolution : 0.1 deg c rate of heating (deg c per minute), abbe refractometer : safety bs en 60950-1:11/2006 emc en 55024 : 10/2003 en 55020 : 11/2005, tlc kit : outstanding standardization and quality control exceptional adherence, hardness and surface homogeneity. analyzing samples with high matrix- load without sample preparation. multiple samples analyzed in parallel.highly cost-efficient, fast and economical, centrifuge : 6000rpm, corkboring machine :adjustable guide that permits holes to be bored in any part of a stopper, the knurled chuck - 9/16" (14mm) shank of the eight, plated-steel borers included with the unit. the steel borers range from 3/16" to 5/8" (4.8mm to 15.9mm) in 1/16" (1.6mm) increments,, distillation apparatus : single distillation 5 litres, oven hot air : 14" 14" 14 , voltage stabilizer : 2kv, vertex shaker : 6 tube capacity, mixer small : moter capacity 900 watt, water bath(cu) : 4 , heating mantle with energy regulator : 500 w,2litre, single crucible heater : helical wire coil moldatherm insulation platinel ii thermocouple with 10tm compensated lead wire and polarized plug ceramic fiber hearthplate programmable heat-up to setpoint temperature indicates setpoint and process temperatures temperature: 1200 c (2192 f) maximum crucible sizes: 5 (top vestibule id) x 8 (heated depth), water bath rectangularsingle walled : 6 hole 8 ltrs., water bath rectangular :2 hole, kjeldahl distillation unit : unit of 3 tests, microwave oven : 30 ltr convection compatible, soleextractionunit apparat
Tender For corrigendum : supply of power and instrumentation cables : : - vz2853299015_3cx10mm2_armoured_unshield black , vz2855298024_12cx2.5mm2_frls_ outer sheath black , vz2851297015_1c x 25mm2 _earthing cable sheath green_1 , vz2851297015_1c x 25mm2 _earthing cable sheath green_2 , vz2851297015_1c x 25mm2 _earthing cable sheath green_3
Tender For corrigendum : rnm of complete control and instrumentation system including regulating controls, interlocks, operator interface units and requisite terminator of one unit unit5 of mahagenco cstps, chandrapur-500mw
Tender For corrigendum : supply of instrumentation spares for daikin chiller skid system of esp d d - plc cpu 226, part no - se8211311 or equivalent, item code - slocacs120094-1 , touch panel k - tp178 human machine interface hmi, part no - se8211046 or equivalent, item code- slocacs200082-1 , communicationcable, item code- sacs200086-1 , low pressure transducer lp se8121019 or equivalent, item code- s4903391 , discharge hp pressure transducer, part no-se8121020 or equivalent, item code- s4903387
Tender For work contract for expert servicing of turbine supervisory instrumentation (tsi) and 6.6 kv auxiliaries vms system of 210 mw atps mppgcl chachai.