Get complete information related to latest Insulated Cable Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Insulated Cable Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Insulated Cable Tenders.
Tender For supply and end termination of over current protection system with residual current of 30 ma along with full end termination suitable for office wiring along with residual current protection operated on 190-240v v ac supply with load current 32 a confirming to id 12640 (part 2): 2008 iec61009-1: 1996 or latest with copper terminal connector suitable for 2.5 dia aluminium tubular busbar for 32a copper palm 1 copper cu etp cw 0041a and aluminium barrel aluminium al 99.5 cable connector temperature resilience, corrosion resistance size: 2.5 sqmm confirming to is: 5561-1970 with maximum temperature rise of 90 degree celsius. material shall be confirmed to designation a6 of is:617-1959. breaking resistance for barrel 85 n/m sq m and for palm 225 n/m sq m with stretching a5% for barrel must be for palm 32. [ warranty period: 30 months after the date of delivery ]
Tender For supply of terminal ends for aluminium conductors of insulatedcables (compression cable lugs) conforming to is 8309,terminal ends for aluminium conductors of insulatedcables (compression cable lugs) conforming to is 8309
Tender For supply of supplying and fixing heavy duty iron stand,supplying and laying 3 core 2 point 5 sqmm copper cable,supplying and fixing programmable timmer,removing of all window split ac,closing the opening of window ac,supplying and fixing spn 4 way single door mcb db,wiring for light power plug with 2 into 4 sqmm copper cable,supplying and fixing 20 a sp mcb,supplying and fixing 40 a dp isolator,supplying of inverter type split ac,itc of inverter type split ac unit,supplying and fixing extra copper pipe line,providing and fixing pvc pipe
Tender For corrigendum : supply of supplying of 1.5 tr nominal capacity invertor type metal body , installation, testing and commissioning of of 1.5 tr inverter type ductable air cooled split ac unit as per item no.1 above in equipment room , providing and fixing heavt duty powder coated m s stand of suitable size made out of suitable guage ms shee , supply and fixing of 3 core 2.5 sq mm control cum transmission wiring and ac power supply cable of shielded copper conductor for looping between indoor and outdoor , supply and fixing of 4 core 1.5 sq mm control cum transmission wiring and ac power supply cable of shielded copper conductor for looping between indoor and outdoor , supply installation testing and commissioning including vaccumiazation and nitrogen testing of , supply installation testing and commissioning including vaccumiazation and nitrogen , supplying and fixing of 25 mm sizes of rigid upvc piping from outlet socket of ac unit complete with elbow , supplying and fixing dp sheet steel enclosure on surface or recess along with 25 or 32 a 230 v c curve dp mcb , supplying and fixing 5 amps to 32 amps rating, 240 or 415 volts c curve miniature circuit breaker suitable for inductive load of single pole and neutral , providing and fixing supply air grills of powder coated aluminum construction having a free area of not less than 70 percent without volume control dampers , supplying and installing of 150 mm width 50 mm depth 1.6 mm thickness nominal size of perforated hot dipped galvanised iron cable tray
Tender For corrigendum : supply of supply installation testing and commissioning of 1600 kva 11 by 0.433 kv delta star step down as per atc attached , supply installation testing and commissioning of 11 kv 630a rated breaking capacity 21ka for 3sec sf6 insulated rmu as per atc attached , sitc of 2500 amps sandwich type bus trunking as per atc. , supplying and laying of 3 core 150 sqmm xlpe insulatedcable on the existing cable tray or rcc or hume or metal pipe or susface as per atc attached , supplying and laying of 3 core 150 sqmm stranded aluminium conductor conductor screen with extruded semi conducting compound xlpe insulatedcable in the existing masonary duct as per atc attached , supplying and makingoutdoor cable end termination with heat shrinkable joint for 3 core 150 sqmm 111 kv grdae as per atc attched. , copper plate earthing complete as per atc attached. , gi plate earthing complete as per atc attached. , providing 50 mm and 5 mm thick copper strip on surface as per atc attached. , providing 25 mm and 5 mm thick copper strip in 40 mm gi pipe as per atc attached. , providing 25 mm and 5 mm thick copper strip on surface as per atc attached. , supplying and laying of 80 mm gi pipe a-class on surface as per atc attached. , supplying and laying of 80 mm gi pipe a-class in ground as per atc attached. , supplying and laying 120 mm dia dwc hdpe pipe as per atc attached. , supply and installation of 4.5 kg co2 type fire extinguisher isi marked as per atc attached. , supply and installation of 06 kgs abs powder type fire extinguishers as per atc attached. , supply and installation of 3 mm thick rubber mat suitable for 33 kv as per atc attached. , supply and installation 0f 4 nos 9.5 ltrs capacity gi bucket as per atc attached. , supply and installation of first aid box as per atc attached. , supply and fixing safety instruction chart as per atc attached. , supply and fixing shock treatment chart as per atc attached. , supplying and fixing of 40mm x 40mm x 5mm thick angle iron frame complete as per atc attached. , supplying and fixing of single line diagram and layout diagram complete as per atc attached.
Tender For supply of copper cable 1.5 sq.mm. single core stranded annealed tin coated e beam irradiated cross linked polyolefin insulatedcable suitable for 1.8/3 kv grade as per rdso specn. no. elrs/spec/elc/0019 rev.4 of feb.2018 or latest. [ warranty period: 30 months after the date of delivery ]