Get complete information related to latest Insulating Kit Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Insulating Kit Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Insulating Kit Tenders.
Tender For corrigendum : providing of repair and overhauling service - thermal insulation of hp and ip turbine of tg 01 during capital overhauling; thermal insulation of hp and ip turbine of tg 01 during capital overhauling; yes; buyer premises
Tender For bid to ras corrigendum : supply of electrical testing and calibration c c - testing of transformer tan delta , testing of lt breaker_starter , testing of ht breakers , testing of relays , testing of over load relay thermal , partial dischrg test for trmr , testing of third harmonic la , test - insulating matrubbeberting matrub , testing insulation resistance half yearl , polarization index test , transformer oil testing , calibration of meter , calib- elec. measuringelect. measuring i , testing of vcb bottle oisd-137 , thermography testing of panel , oil filtration of transformer , electrical safety audit , sup 33.0kv rubber hand gloves , current transformer testing upto 500a , vlf testing of cable report submission , winding temperature pc414 , testing and calib- otianalog_digi , liasoning charges , drop ourt fuse of 11 kva replacement , lightining arrestor of 11 kva replacemen , gos switch service and painting , ht cable insulation test , ht breaker lbs service , multi function meter mfm ) /bid number : gem/2025/b/6774505 * /dated: 10-10-2025 & & / bid document 1 / 25
Tender For thermal insulation works pertaining to boiler and its auxiliaries of unit-ii, rgtpp and thermal insulation works on turbine, pipelines, valves etc. of unit-ii during overhauling at rgtpp, khedar, hisar.
Tender For thermal insulation (legging) work and providing & fixing of different valves for cooling water pipe line of generators at mb-ii, dharasu power house, chinyalisaur, uttarkashi.
Tender For corrigendum : supply installation and commissioning of central ac to nirmithi kendra, raichur - lifting shifting, loading unloading and installation ,transportation charges, lifting shifting, loading unloading and installation ,transportation charges, supply & installation of propeller fan. 100 cfm, supply & installation of propeller fan. 100 cfm, supply & installation of mixed flow inline fan. 500 cfm 15mm static, supply & installation of mixed flow inline fan. 500 cfm 15mm static, supply & installation of louverwith bird mesh, supply & installation of louverwith bird mesh, supply & installation of pvc pipes. dia -110mm, supply & installation of pvc pipes. dia -110mm, supply & installation of pvc pipes. dia -160mm, supply & installation of pvc pipes. dia -160mm, supply & installation of dise valve. dia -100mm, supply & installation of dise valve. dia -100mm, supply & installation of uninsulated flexible duct. dia -150mm, supply & installation of uninsulated flexible duct. dia -150mm, supply installation testing and commissioning of al.powder coated collar damper., supply installation testing and commissioning of al.powder coated collar damper., supply, installation testing and commissioning of aluminum extruded powder coated grill with blade deflection of 0 - 30 deg as required., supply, installation testing and commissioning of aluminum extruded powder coated grill with blade deflection of 0 - 30 deg as required., supply, installation, testing and balancing of gss volume control dampers with operating handle for supply air duct branches. the volume control damper shall be of low leakage type with the outer shell constructed of 1.6mm thick galvanized steel frame and the blade/leaf with 1.6mm thick gss. and with necessary flanges for connection etc., as per specification., supply, installation, testing and balancing of gss volume control dampers with operating handle for supply air duct branches. the volume control damper shall be of low leakage type with the outer shell constructed of 1.6mm thick galvanized steel frame and the blade/leaf with 1.6mm thick gss. and with necessary flanges for connection etc., as per specification., supply ,installation and testing of class o 9mm thick, elastomeric nitrile rubber or physically cross linked polyolefin foam thermal insulation., supply ,installation and testing of class o 9mm thick, elastomeric nitrile rubber or physically cross linked polyolefin foam thermal insulation., supply ,installation and testing of accoustic lining with physically crosslinked open cell polyolefin foam insulation for supply and return duct of density 30kg/m3 of fire retardant grades with thickness of 10 mm nrc of material should be atleast 0.35 tested as per iso 354-2000 and calculated in accordance with astm c423-90a., supply ,installation and testing of accoustic lining with physically crosslinked open cell polyolefin foam insulation for supply and return duct of density 30kg/m3 of fire retardant grades with thickness of 10 mm nrc of material should be atleast 0.35 tested as per iso 354-2000 and calculated in accordance with astm c423-90a., supply, fabrication, installation fire resistance flexible double canvas sleeve for ductable split and airwasher fan ., supply, fabrication, installation fire resistance flexible double canvas sleeve for ductable split and airwasher fan ., supply, fabrication, installation and testing of sheet metal ducts (factory fabricated ducts) in accordance with the approved shop drawings complete with all accessories like vanes, flanges, suspension rods, anchor bolts, gi bolts & nuts, canvas connections, duct dampers & splitter dampers etc.,and as required by the specifications. all size duct should be with tdf joints. no c & ss clip joints should be used 24g, supply, fabrication, installation and testing of sheet metal ducts (factory fabricated ducts) in accordance with the approved shop drawings complete with al