Tender For corrigendum : providing of custom bid for services - pde1s24244 insulationresistance improvement and bearing replacement of lt motors installed at paradip refinery and petrochemical complex paradip odisha
Tender For supply of digital high voltage insulation tester. [digital high voltage insulation tester. test voltage 250v to 5kv insulationresistance measurement rang up to 1 tera ohm with polarization index(pi) and di-electrical absorption rate(dar) testing facility. make: fluke , flair.]
Tender For segregation of 11 kv mixed feeders at tonk circles of jaipur discom of rajasthan state under revamped reforms-based and results linked distribution sector scheme (rdss) on turnkey basis against tn-583 - pcc poles, pcc pole 9 mtrs long (400 kg), pcc pole 9 mtrs long (200 kg), outdoor 11 kv o/d vcb kiosk complete with accessories including use of special tools, armoured cable of size 2c x 4 sq.mm. 1100 volts pvc insulated including supplyof ferrules, control cable of size 12c x 2.5 sq.mm. 1100 volts pvc insulated including supply of ferrules, overhead steel cored aluminum acsr dog[100sqmm(6+7) /(4.72+1.57)] conductor complete in all respect as per latest specification and drawing, overhead steel cored aluminum acsr rabbit conductor in all respect, earthing rod sets for s/s made with ms rod (galvanized ) 20 mm dia, 3 meter length with gi wire and clamp as per latest specification and drawing adopted & approved by nigam., ctpt structure set (galvanized), 11kv ct pt set(200/5 amp.), mip meter box for meter with ttb, go double break without eb isolator on existing bracket complete in all respect as required including hardware, nut, bolts & washer etc., 11kv ( with 9 x 24 kv post insulator ) 400 amp., horn gap sets on existing brackets in all respect as required including hardware nut & bolt & washer etc., 11kv ( with 6 x 24 kv post insulator ) 1 set=3 nos, supply of insulators, 11kv porcelain disc.insulators b&s type 45kn, hardware for 11kv disc insulator b&s type 45kn, composite polymer insulators, 11kv polymer disc.insulators t&c type 45kn, hardware for 11kv disc insulator t&c type 45kn, 11 kv composite polymer pin insulator complete in all respect, pg clamps for suitable acsr dog conductor, pg clamps for suitable acsr rabbit conductor, 11 kv danger plate of size 200 x 250 mm complete in all respect, supply of angle and channel, m.s channel 100x50x6 mm, m.s channel 75x40x6 mm, m.s. flat 50 x 6 mm (galvanized), 1.4 mtr channel bracket with clamp, supply of lightening arrestors, substation type 9kv, 10ka station class (1set=3 nos.) lightening arrestors., 11kv double pole line structure set for cut point complete on existing poles in all respect with clamp, as required made from m.s.channel 100 x 50 x ismc ( 9.56 kg. per mtr.) isa m.s.angle 65 x 65 x 6 mm, m.s.angle 50 x 50 x 6 mm and m.s.flat 50 x 6 mm (galvanized as per is), gi stay set (galvanized) complete (stay rod 16 mm dia,1.8 m long,anchor plate 300x300x4 mm,12 mm dia turn buckle) including stay clamps,, strain/guy insulator for stay set, 7/10 swg gi stay wire, gi wire 8swg, underground cable for working voltage of 11kv aluminium conductor (is 7098) cable xlpe armoured, under ground cable of size 3x185 sq.mm for 11 kv, g.i. pipe of 125 mm diameter, b-class (is:1239 mark), gi pipe for cable support at pole ( each 3.3 mtr ), cable for11 kv aluminum conductor xlpe armoured ht cable, xlpe 3x185 sq.mm h.s. on indoor type, xlpe 3x185 sq.mm h.s. on outdoor type, xlpe 3x185 sq.mm h.s.s.t. joint, 11.4 mtr. long lattice tower made of 50 x 50 x 6 mm m.s. angle with 50 x 6 mm m.s. flat for bracing as per nigam specification, 11kv cross arm with top hamper with clamps made of ms angle 65x65x6mm, clamp 50x6 mm, earth clamp 50x6 mm (galvanized), fixing of 11/0.4 kv substation structure set for three phase 63 kva transformer on double poles in all respect. weight (as per specification and drawing with go channel) approx=219.54 kg (all galvanized as per relevant is), 11 /0.4 kv al wound, three phase distribution transformer (completely self protected with provision of lt bushing box), 25 kva, 63 kva, 6.35/0.24kv s/s structure set for single phase transformer on single 9mtr, 400kg pcc pole in all respects., 11kv 100 amp drop out cum isolator with 3.0 amp. fuse & 12 kv post insulators., lt xlpe cable, size 4cx70 sq. mm, size 4cx120 sq. mm, aerial bunched cable, aerial bunched cable 3cx25+1x25 sqmm, aerial bunched cable 3cx50+1x35 sqmm, lt distribution pillar
Tender For tender for supply of servicing and relay testing for lauritz kundsen l and t make acbs - repair servicing of 415v cpower acb details as per sl no 1 in boq , repair servicing of 415v u power acb details as per sl no 2 in boq , testing and calibration of acb details as per sl no 3 in boq , servicing of apfc panels of lauritz knudsen details as per sl no 4 in boq , testing calibration of relays on acbs details as per sl no 5 in boq , testing calibration ht relays details as per sl no 6 in boq , insulationresistance check details as per sl no 7 in boq , supply of maintenance kit for c power details as per sl no 8 in boq , supply of maintenance kit for u power details as per sl no 9 in boq , supply and replacing of acb details as per sl no 10 in boq , supply and replacing of acb front facia details as per sl no 11 in boq , supply and replacing of acb fixed arcing details as per sl no 12 in boq , supply and replacing of acb moving arcing details as per sl no 13 in boq , supply and replacing of acb cradle facia details as per sl no 14 in boq , supply and replacing of acb hardware kit for motor details as per sl no 15 in boq , supply and replacing of acb c power details as per sl no 16 in boq , supply and replacing of acb u power details as per sl no 17 in boq , supply and replacing of acb relay details as per sl no 18 in boq
Tender For corrigendum : supply of various items of disaster management and electrical safety for atp, anpara - rotary rescue saw for fire wing s disaster management equipment, chain saw for fire wing s disaster management equipment, chipping hammer for fire wing s disaster management equipment, search and rescue light for fire wing s disaster management equipment, stretcher for fire wing s disaster management equipment, braided rescue rope for fire wing s disaster management equipment, fire retardant dungaree for cisf fire unit, as per attached specification, electrical safety shoes, size-7 uk, safety standard: ansi z41 & astm 2412-05, material: leather/pu/tpu/eva, wedge sole, steel toe cap, anti-static inner sole, electrical shock resistance up to 11kv for 1 minute., electrical safety shoes, size-8 uk, safety standard: ansi z41 & astm 2412-05, material: leather/pu/tpu/eva, wedge sole, steel toe cap, anti-static inner sole, electrical shock resistance up to 11kv for 1 minute., electrical safety shoes, size-9 uk, safety standard: ansi z41 & astm 2412-05, material: leather/pu/tpu/eva, wedge sole, steel toe cap, anti-static inner sole, electrical shock resistance up to 11kv for 1 minute., electrical safety insulated hand gloves, size m, type of material-rubber, test voltage 12kv for 1 min, min. length-14 inch, leakage current 1ma/kv, electrical safety insulated hand gloves, size m, type of material-rubber, test voltage 36kv for 1 min, min. length-14 inch, leakage current 1ma/kv, industrial safety helmet, safety standards: iso 3873:1977 & en 397, industrial safety belt with harness full body fall protection with scaffolding hook double lanyard, minimum weight capacity: 100kg, standards: is 3521 (1999), electrical rubber mats sheet, size: 1meter x 2meter x 3mm, min. insulationresistance voltage: 1kv, standards: is 15652:2006