Get complete information related to latest Interfacial Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Interfacial Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Interfacial Tenders.
Tender For supply of laminar air flow - 4000658, 1.000, laf specifications:-1) horizontal laminar air flow unit - platform height should be 36 inch from ground floor2) laf working station size length 40 x hight 24 x width 24 inch single undevided working space.3) lau should have closing sheet of transparent acrylic sheet.4) 2x stage filtration5) pre-filter - 10 with efficiency of 90 percent (washable hdpe media with ss 304 frame)6) supply filter - mini pleat hepa filter efficiency 99.999 percent at 0.3m (h-14)eu-14 high efficiency particulate air (aaf india ltd.), as per iest rp cc002.47) material - stainless steel 304 grade 1.2 mm8) maximum work area - maximum coverage for easier hand movements inside the cabinet. the unit has a 10 slope for operators comfort.9) motor blower assembly10)noise level - less than 60db at 1 meter from the face of the filter11)cleanliness - iso standard 14644-1 class 512)pressure gauge - digital sensor display13)air velocity - 90 fpm at 6" from face of the filter +/- 20 feet per minute14)air velocity 0.36 to 0.54 m/s and 70 to 100ft/min.15)feather touch16)provided with valid calibration certificate for laf.17)microprocessor controller for: digital pressure gauge rated filter life indicator timer for uv light uv light hour meter interlock uv and light switch18)1 year warranty for all electrical/electronic/mechanical parts i.e. whole unit.19)should be provided with two three pin plug for electricity supply both side of lfu inside for instrument attachment.20)adequate diffuse lighting, provided by fluorescent or led lights is necessary for the working area.21) eligibility of supplier - min 5 supply records in a financial year with satisfactory reports.
Tender For special repairs replacement to e/m equipments and infrastructure at af stn jamnagar under ge (af) jamnagar no 1 - supply, installation and testing air cooled inverter based split ac unit with cooling functions and suitable to operate at ambient conditions of (22 deg c + 3 in cooling mode) air conditoner will have following conditons :- (a) refrigerant - r-410 a/r-32 (b) eer- 5 star rating (c) tonnage - 1.5 tr (d) indoor noise level - not more than 40 db (e) filter - as recommended by oem (f) remote - as recommended by oem including 02 nos remote bty (g) temp display, turbo mode and auto swing facility all specification will be as per is-1391 (part 2) and latest amendments as specified as directed by engineer-in-charge., supply, installation and testing air cooled inverter based split ac unit with cooling functions and suitable to operate at ambient conditions of (22 deg c + 3 in cooling mode) air conditoner will have following conditons :- (a) refrigerant - r-410a/r-32 (b) eer- 5 star rating (c) tonnage - 2 tr (d) indoor noise level - not more than 40 db (e) filter - as recommended by oem (f) remote - as recommended by oem including 02 nos remote bty (g) temp display, turbo mode and auto swing facility all specification will be as per is-1391 (part 2) and latest amendments as specified as directed by engineer-in-charge., note for item no 1 & 2 :- the cost of following items deemded to be included in quoted rate.(a) copper pipe duly insulated between indoor/outdoor unit upto lenght 10mtr for each unit (b) ms bracket for outdoor unit duly power coated with fixing arrangement.(c) making of hole in walls including civil work , sleeves and making good to the disturbed surface/wall.(d) testing and commissioning of the air conditioner to the entire satisfaction of engineer in charge(e) pvc round sheathed copper cable of suitable size for connecting indoor and outdoor unit upto supply point as per site requirement (f) taking down of existing ac and deposited to e/m store yard without any damage., supply and installation of voltage stabilzer for automatic operation single phase naturally air cooled indoor type and designed for input varioution between 180v to 250v without voltage stabilzed at 230v with accuracy of (+) 2.5% and capacity 4 kva as specified as directed by engineer-in-charge., supply and installed voltage stabilzer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 180v to 250v without voltage stabilzed at 230v with accuracy of (+) 2.5% and capacity 5 kva as specified as directed by engineer-in-charge., material & labour for sub main wiring with 2 run single core multistranded copper conductor cable, of size 4.0 sqmm each, pvc insulated, unsheathed, fire retardant, low smoke (frls) drawn through and including pvc casing capping with all necessary fitting and including one run of single core multistranded copper conductor cable, of size 4.00 sqmm, pvc insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete all as specified and as directed by engr-in-charge.note: 2 runs of main copper conductor, one run earth wire and pvc casing capping will be measured as one running meter for payment., s&f sheet metal enclosure , 20a single pole and neutral with a two pin and earth plug and socket complete in metal clad board (industrial type) with one single pole mcb 32 amp fixed properly on in concealed position all as specified as directed by engineer-in-charge., supply, installation, commissioning and testing in replacement of loop card having 254 devices of both detectors and modules in a single line circuit, slc supports both class a and class b wiring complete as specified and as directed by engineer-in-charge. make: ravel/honeywell/ceasefire industries pvt ltd, supply, installation, commissioning and testing in replacement of addressable smoke detector with base with binary coded address setting. dual leds for 360 visibil