Get complete information related to latest Irradiance Meter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Irradiance Meter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Irradiance Meter Tenders.
Tender For corrigendum : annual rate contract of instrument maintenance jobs for the year 2025-26 - removing of level gauges, fixing of level gauges, transportation of level gauges, removing of level switches, fixing of level switches, removing of leveltrols, fixing of leveltrols, transportation of leveltrols, removal of differential pressure/ pressure transmitter with or without capillary with flange size upto 80mm and upto 600# rating, diaphragm seal type transmitter, ordinary transmitter, fixing of differential pressure/ pressure transmitter with or without capillary, diaphragm seal type transmitter, ordinary transmitter, fixing of differential pressure/ pressure transmitter with or without capillary, diaphragm seal type transmitter, ordinary transmitter, removal of diaphragm seal type pressure/d.p gauges with flange size upto 80mm and upto 600# rating, fixing of diaphragm seal type pressure gauges with flange size upto 80mm and upto 600# rating, transportation of diaphragm seal type pressure gauges / ordinary pressure gauges, removal of pressure switch, installaltion of pressure switch, removal of glass tube type rotameter, removal of magnetic type rotameter, fixing of glass tube type rotameter, fixing of magnetic type rotameter, transportation of rotameters (any type), removal of different type of flow meters, upto and including 4" size irrespective of pr. rating, above 4" size irrespective of pr. rating, fixing of different type of flow meters, upto and including 4" size irrespective of pr. rating, above 4" size irrespective of pr. rating, transportation of different types of flowmeters irrespective of size & pr rating, removal of orifice plate from flange assembly, upto & including 6" line size (of any rating) ., more than 6" line size (of any rating), fixing of orifice plate at flange assemply, upto & including 6" line size (of any rating) ., more than 6" line size (of any rating), removal of power cylinders, size upto 4" dia, size > 4" dia, mounting of power cylinders., size upto 4" dia, size > 4" dia, transportation of power cylinders, shifting of empty or filled calibration gas cylinders, removal of thermowells alongwith thermocouple, removal of thermocouple without thermowells, fixing of thermowells alongwith thermocouple, fixing of thermocouple without thermowell, removal of weep hole probes of urea reactor, fixing of weep hole probes of urea reactor, laying of tubing., size 6/8mm of copper or ss tube, size 10/12mm of copper or ss tube, removal of tubing, size 6/8mm of copper or ss tube, size 10/12mm of copper or ss tube, laying of gi pipe., upto size 1/2", > 1/2" , upto size 1", > 1" , upto size 2", > 2" , upto size 4", fabriction & laying of impulse lines/air header etc. of following sizes of pipes (non ibr) including welding upto sch 40, upto & including 1/2" carbon steel, upto & including 1/2" stainless steel/alloy steel, > 1/2" upto & including size 1" carbon steel, > 1/2" upto & including size 1" stainless steel/alloy steel, > 1" upto & including size 2" carbon steel, > 1" upto & including size 2" stainless steel/alloy steel, > 2" upto and including size 4" stainless steel/alloy steel, fabriction & laying of impulse lines/air header etc. of following sizes of pipes (non ibr) including welding more than sch 40, upto & including 1/2" carbon steel, upto & including 1/2" stainless steel/alloy steel, > 1/2" upto & including size 1" carbon steel, > 1/2" upto & including size 1" stainless steel/alloy steel, > 1" upto & including size 2" carbon steel, > 1" upto & including size 2" stainless steel/alloy steel, fabriction & laying of impulse lines/air header etc. of upto & including 1/2" carbon steel of pipes (ibr) more than sch 40, removal of impulse line/air header of ibr/non-ibr (for all ratings), size upto & including 1/2" of carbon steel/gi, size > 1/2" upto & including 1" of carbon steel/gi, size > 1" upto & including 2" of carbon steel
Tender For corrigendum : supply of o2 detector (sensor+ transmitter) . range: 0-25% vol. , lcd display unit with controller. application: measurement of oxygen and toxic gas
Tender For purchase of sports exercise physiology lap equipments - cardiopulmonary exercise testing system system should be compact can be used in laboratory operation and low maintenance costs and easy servicing. system should be state of the art computerized telemetry breath test analyzer for on-line breath by breath measurement of exercise test of respiratory system to measure following parameter: time, ve, bf(rr), hr, feo2, feco2, peo2, peco2, vo2, vco2, ve/vco2(eqco2), ve/vo2(eqo2), rq(rer), vd/vt, vo2/kg, vo2/kg/hr, met, watt(work), hr, ttot, ti, te, ti/te, ti/ttot, pef, pif, br, vet, sum, tv/te, o2 kinetics, oxygen deficit, oxygen debt parameters and indirect calorimetric. wireless hr recording system, indirect cardiac output by wassermann algorithm system should comply ats and ers guide line and it should be ce certified., iso certified system should have automatic ambient conditions measuring system. system should work under temperature range 0 to 50 celsius. system should have facility for automatic calibration of analyzers. volume transducer calibration with precision calibration syringe. system should meet following technical specification flow rate measurement: measuring headpiece should be either through turbine /dvt/ pneumotach and dead space less then 40 ml, it should not be affected by humidity , flow range +/- 18 l/s and accuracy 2% oxygen analyser : should be either electrochemicalcell/paramagnetic and measurement range 0- 100 %,response time t90 100 ms and accuracy +/-0,04 % and- resolution 0,02 %carbon dioxide analyser : should be ndir (infraredabsorption) and measurement range 0 - 10 %,-response time t90 90 ms , accuracy +/- 0,04 %, andresolution 0,02 % software should support latest windows or latest andin corporate customized predicted normal equations.software should be capable of changing graphics displays during real time testing. system should have facility for automatic treadmill or bicycle ergo meter control. should be supplied with software, standard accessories for operation manual carrying case for field use. system should be supplied with latest data acquisition system, deskjet printer and ups. system should comply en iso 13485:2003, en iso 9001:2000, ec certificate93/42/eec, programmable treadmill running machine with user terminal (display &keyboard) stand- alone and remote control via rs232 running surface: l:170 cm (minimum), w: 65 cm (minimum) maximum possible load: 200 kg (440 lbs) speed range: 0-40 km/h elevation: 25% (14 maximum elevation) motorized adjustment, reverse belt rotation. motor system 3.3 kw, single phase ac motor, maintenance free and brushless power transmission: frequency inverter, poly v- belt, very quiet operation safety system: emergency-off safety stop switch (safety lanyard with actuator, pull cord and clip); potential equalization bolt; transformer for potential-isolation from the mains ambient condition: temperature: +10to +40 degrees c, humidity 30 to 70% display (resolution): lcd display heartrate monitoring: wireless transmitter; the treadmill should be able to interface with well-known compatible metabolic gas analyzer as per standard and custom exercise protocols different programs safety harness-1. indispensable accessory for stress testing, accident prevention and for the general safety of athletes.2. safety arch with different heights and widths to fit all running machines.3. an emergency stop at the crossbar of the safety arch allows automatic stop of the running belt in the moment a fall occurs.4. the harness and chest belt (available in 5 sizes: xxs, s, m, l, xl) secure the subject and prevents falling over to the front.5. chest belt straps do not pinch or restrict the athlete", programmable ergometer functional design and excellent stability, load up to 160kg. easy to use saddle, handle bar and pedals speed independent and dependent power control handle bars are easy to change to suit different tests, rotatable by 360 degrees. mechanical/motor-assisted seat a
Tender For supply of supply of sensors cartridge - sensor cartridge for ash3 , supply of sensor cartridge for ozone , supply of sensor cartridge , supply of sensor cartridge for teos 015 ppm , supply of sensor cartridge for c4f6 ch2f2 0 40 ppm , supply of sensor cartridge for h2 0 1000ppm , pyrolyser for c4f6 ch2f2 midas fixed gas transmitter detector part no midas t np1 , pyrolyser for nf3 midas fixed gas transmitter detector part no midas t 00p , sense point xcd o1ss 0 25percent v v , black ventilated top cover for pyrolyzer units part no midas a 103 , internal air filter for midas gas detector part no midas a 009