Get complete information related to latest Iso 18001 2007 Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Iso 18001 2007 Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Iso 18001 2007 Tenders.
Tender For procurement of flood fighting materials (geo-textile bags type-a and geo-textile bags type-c ) for water resources department. (for dhubri wrd) (ph-iii ) - supply of geo-textile bags of type-a (1.03 0.70 m) inner to inner made of geo-textile non-woven fabric sheets of 400 gsm manufactured from 100% virgin polypropylene (pp) fibre with minimum properties as per is 16653:2017 i. wide tensile strength (md) 20kn/m & wide tensile strength(cd) 20 kn/m ii. elongation (md) 50% & elongation (cd) 50% iii. abrasion 95% iv. trapezoidal tear strength (md) 450n & trapezoidal tear strength (cd) 450n v. cbr puncture strength 4000n vi. permittivity 1.10s 1 vii. permeability 40l/m2/sec viii. aos 75 micron ix. uv resistance @ 500 hours retained tensile strength (md) & (cd) 80% x. mass 400 gm/m xi. thickness at 2kpa 3 mm xii. seam strength 80 % of actual fabric strength. stitching of bags should be ring spun yarn stitches with 2500-3000 denier double line chain stitch with overlap with stitches along the edge @ minimum 15 stitches per 100 mm. (bags are to be supplied of 100 numbers in a bundle, properly packed with each bag having proper tag with name of manufacturer, batch number, the gsm and type of polymer encrypted and stitched on top corner and each bag is to be marked with wrd govt. of assam to be printed distinctly. test certificate from approved nabl accredited and iso (certified laboratory should invariably be submitted against each batch of material), supply of geo-textile bags, type c of size 1.50 m 1.00 m, inner dimension made of composite layers of geo-textile as per specifications below:woven geo-textile for the outer cover. the woven geo textile is woven with uv resistant slit film tape fibre with mavr values of the following properties. geo-textile used to manufacture geo-textile bags should have high mechanical properties for enhanced durability along with enhanced puncture, abrasion and u.v. resistance characteristics. geo-textile should be inert to biological degradation and resistant to naturally encountered chemicals, alkalis, and acids. weight (iso-9864/astmd 5261) 250 gms/sqm. tensile strength (md) (astmd 4595) 35 kn/m. tensile strength (cd) (astmd 4595) 35 kn/m. tensile elongation (astmd 4595) 5% & 30%. grab elongation (astmd 4632) 5% & 30%. tensile strength (astmd 4632) = 1.5 kn. uv resistance (astmd 4355) = 70%/500 hrs.non-woven geo-textile for the inner layer. it is needle punched non-woven geo-textile made of 100% polypropylene staple fibers which are formed into a random network for dimensional stability. it should resist uv degradation, rotting and alkalis. weight (iso-9864/astmd 5261) 300 gms/sqm. tensile strength (md) (astmd 4595) 12 kn/m tensile strength (cd) (astmd 4595) 12 kn/m tensile elongation (astmd 4595) 5% & 30% grab elongation (astmd 4632) 5% & 30% tensile strength (astmd 4632) = 1.5 kn uv resistance (astmd 4355) = 70%/500 hrs(bags are to be supplied of 100 numbers or part in a bundle, properly packed with name of manufacturer and batch number is to be marked on each bag with wrd govt. of assam to be printed on each bag and mentioning properly the gsm and type of geo bag polymer. test certificate from approved nabl accredited and iso certified laboratory should invariably be submitted against each batch of material)
Tender For supply of powder free unsterile gloves made of nitrile formulation. should be natural latex fr ee.should be highly puncture resistant and excellent flexibility to allow full range of motions.s hould be available in various sizes.it should have iso/bis/ce certificate.it should be approved by dc gi. unit: pair ]
Tender For supply of m.s. enclosure with all accessories as per annexure attached for 20 fuse alarm system ( for t wenty fuse) drg. no.s&t/by/f-346, 346/1, 346/2, 346/3. only valid iso-9001 (qms) certified firms to quote. party to submit oem /authorization certificate with warranty. [ warranty period: 30 months after the dat e of delivery ]
Tender For supply of 2ton electric chain hoist with motorized ct movement, lifting capacity 2 ton, heig ht of lift 8 meters, with electromagnetic brake and limit switch, iso duty m4, supply should accompany test certificate as per is3832 and iso9001, inspection certificate and warranty certificate make: speed, indef, m orris ,stahl, eastman, tayrus, columbus mckinnon-(cm) only [ warranty period: 12 months after the d ate of delivery ]
Tender For supply of indexible inserts part no cnmg -190612 grade tn 2000, conforming to is 11677:2004, iso 3364:1997 having make: widia, sandvik or ceratizit only along with proof of purchase with authoriz ed dealership certificate. ]
Tender For supply of rockwell hardness block, scale hrc crm range 10 - 30 hrc as per is: 1586 (part 2) 2018 or iso 6508-2:2015 as per detail in annexure - a with nabl accreditation calibration certificate ]
Tender For tender for various equipment for psm department - ? the charts shall be thick laminated on both side and fixed to a 3 mm hard board screwed from back which shall be hanged on the wall with strips of aluminium/wooden screwed on wall and chart hard board ? it shall have provision for wall hanging with two hooks ? the size of each chart shall be: 24 x 36 ? the printing shall be on photo paper with glossy/matt finish and shall have multicoloured pictorial diagrams/flow chart ? the size of the fonts shall be readable after fixing on the wall at height of 6-7 feet. ? the company shall be iso certified and certificate shall be enclosed. 1. typhoid fever (paratyphoid fever, enteric fever) 2. food poisoning (infection type, toxin type) 3. intestinal tuberculosis 4. acute infectious diarrhoea 5. hospital waste management. 6 amoebiasis (entamoeba histolytica) 7 trichuris trichiura (whip worm) 8 ascariasis lumbricoids (round worm) 9 enterobiasis vermicularris (pin worm) 10 strongyloides stercoralis (thread worm) 11.acylostoma duodenale (hook worm) 12.tenia saginata (beef tape worm) 13. taenia solium (pork tape worm) 14 hymenolepis nana (dwarf tape worm) 15 dyllobothrium latum (fish tape worm) 16 helminths and protozoa infesting the human intestine 17 chickenpox 18 measles 19 rubella 20.mumps 21. influnza 22 pollomyelitis 23viral fever 24cholera 25 acute diarrhoeal diseases 26 dengue syndrome 27 malaria 28 rabies 29 japanese encephalites 30 scrub typus 31. tetanus 32. leprosy 33. diptheria 34. whooping cough 35. meningococcal meningitis 36. acute respiratory infection 37. tuberculosis part 38. amoebiasis 39. dracunculiasis 40. plague 41. leishmaniasis 42. rheumatic heart disease 43. obesity 44. blindness 45. water pollution 46. air pollution 47. noise pollution 48. contraceptive device 49. nutrition during pregnancy 50. iodine deficiency disorders 51. anemia 52. vitamins function, source & deficiency 53. immunization schedule 54. feeding schedule for pre-term infant 55. normal height-weight table (indian) 56. body surface area & body weight 57. modes of disease transmissions. models of standard size as per mci/nmc guidelines company shall be iso certified 1. protected sanitary well 2. insanitary well 3. step well 4. boring of tube well 5. model of slow sand filter 6. model of rapid sand filter 7. bio gas plant 8. a bore hole latrine 9. septic tank latrine c.s. 10. soakage pit 11. section of septic tank installation 12. wuchereria bancrofti on stand renu 13. itchmite 14. mosquito collecting device 15. spread of typhoid fever 16. leishmani donovani 17. pneumoniac lague 18. small pox & chikenpox comparison 19. xeropthalamia 20. bitots spots 21. atrophic beriberi 22. angular stomatitis 23. pallegeras 24. rickets 25. scurvy 26. kwashiorkar 27. measels 28. marasmus 29. strengyloides stercoralis 30. taniea solium (the pork tape worm) 31. tanea saginata 32. scolex & ripe proglottid 33. echynococcus granulosus (dog tapeworm) 34. life cycle of entamoeba histolytica. 35. life cycle of anopheles 36. life cycle of culex 37. life cycle of an ades (stegomyia) 38. life cycle of louse 39. life cycle of housefly 40. life cycle of sandfly 41. life cycle of itchmite 42. life cycle of rat flea 43. hard tick 44. causes of hookworm infection. 45. marphology of l. donovani 46. trichuri trichuries 47. hookworm 48. neactor americanes 49. facsida hepetica 50. rain water harvesting 51. rainwater recharging company shall be iso certified the slides shall have proper staining broken slides will not be accepted shall be supplied in box. 1. entamoeba histolytica 2. entamoeba histolytica (cyst) 3. entamoeba coli 4. leishmania donovani 5. malarial parasite (in human blood) 6. malarial parasite (signet ring) 7. malarial parasite (oocyst in mosquito) 8. plasmodium vivax 9. plasmodium falciparum 10. trypanosoma in blood 11. echino coccus 12. liver fluke 13. tapeworm scolex 14. tapeworm proglotted (gravid) 15. tapeworm eggs 16. ascaris male 17. ascaris female 1
Tender For corrigendum : two year rate contract for supplying of disposable laboratory items - disposable plastic test tube for cross matching without label; size 13 x 75 mm; capacity 5 ml; pack size :-1 x 100, sample tube for auto analyzer; size 13 x 75 mm; pack size :-1 x 100, sample cup for auto analyzer for i lab; pack size :-1 x 100, disposable micro titer pipette tips up to 200 l; color white; pack size :-1 x 1000, disposable micro titer pipette tips up to 1000 l; color blue; pack size :-1 x 1000, disposable micro titer pipette tips 0.5 to 20 l; color any color; pack size :-1 x 1000, disposable micro titer pipette tips 30 to 300 l; clear graduated; pack size :-1 x 1000 (yellow), transparent plastic sample tube for processing for urine with label and without cap; size 13 x 100 mm; capacity 7 to 8 ml, capillary glass tube for c.t. 75 mm in length, uniform base without anticoagulation; pack size 1x100, micro cover slip for urine for no. 1; square size 18x18 mm smooth edges transparent without any spot; pack size 1 pack = 20 x 10 gms, haemocytometer cover slip no. 1; (size 20 mm x 26 mm x 0.4 mm), new improved neubaur counting chamber having silver coated 9 mm 2 ruled area (for counting wbcs & rbcs), glass marking pencil (red, white, green, blue), glass slide: size length 75 mm, width 25 mm +/- 1.0 mm, thickness 1.35 +/- 0.1mm clean and transparent with ground edges & lint free packing; pack size 1 x 50 iso/ce certified, container for urine, sputum, stool sample collection, leak proof with wide mouth, conical wide bottom & screw cap, 50 ml capacity with label for patient name, ward/opd and registration number, pack size 1 x 100 (urine container), esr disposable pipette with tube, tube 12 x 75 mm clean transparent with graduation at 0.4 ml and 2 ml should allow to fill by air pressure through the rubber piston blood lift up up to zero level. pipette should be made with transparent polystyrene with graduate d scale 0 to 180-200. it should be fine finished; pack size 1 x 100, evacuated blood collection tube with spray dried k2edta with lavender safety closure. it should be made of clear latex free polyethylene terphthalate. size 13 x 75 mm with 4.0 ml, volume capacity. batch wise sterility/pyrrogenicity/toxicity certificate should be given. it should be us-fda/ce certified. firm should provide training to technicians/nurses regularly for blood collection. clinical services should be documented by company. pack size 1 x 100 ( edta vials), sodium citrate evacuated tubes for coagulation test with vacuum (with na. citrate 0.109 m/3.2% plastic tube made of clear latex free polyethylene terphthalaste with light blue safety closure, 13 mm x 75mm vol. 2.7 ml. batch wise sterility/pyrogenicity/toxicity certificate should be given. it should be us fda/ce certified, firm should provide training to technicians/nurses regularly. clinical services should be documented by the company; pack size 1 x 100 ( pt vials), evacuated tubes for silica-clot activator/silicon coated made of clear latex polyethylene terphthalate with safety closure 13 x 75 mm vol. 4.0 ml. it should be us fda/ce certified. batch wise sterility/pyrrogenicity/toxicity certificate should be given. firm should provide training to technicians/nurses regularly. clinical services should be documented by the company; pack size 1 x 100 ((plain vials), blood collection needle 21 or 22 gauge with cap for evacuated tube. it should be us fda/ce certified, sterility certificate firm should provide training to technicians/nurses regularly. clinical services should be documented by the company; pack size 1 x 100 (blood collection needles 21 or 22 gauge), evacuated tube needle holder; pack size 1 x 5, test tube stand 96 holes, 13 mm diameter in two shelves fully autoclavable multi colored; pack size 1 x 1, wash bottle with delivery snore poly ethylene flexible with screw cap 500 ml; pack size 1 x 1, variable volume pipette 10 l to 100 l. fully autoclavable and ivd approve iso/ce certified
Tender For blood collecting bag (350 ml with ring) (single) 1. bag must be made up of dehp (di-2-ethyl hexyl phthalate) plasticized pvc (polyvinylchloride), collapsible non-vented sterile containers complete with collecting tube for completely closed system to avoid the chances of contamination. 2. bag should be flexib le, pre-sterilized, pyrogen free, non-toxic, non-haemolytic & should be made up of biocompatible material. 3 . bag should be free from any risk of contamination and air embolism (closed system) with all leak proof se als (disposable bags). 4. bag should have slits on the both sides to accommodate 5 - 10 ml volume test tub es. 5. the capacity of the bag should be enough to prevent any ballooning/rupture of the bag from the sea m when it is filled up with the requisite volume of blood. 6. tubing of the bag should be flexible, non-kinking , non-sticking, transparent & leak-proof. 7. all the tubings should have same id/segment number as that on the bag. 8. the tube should have multiple printed id/segment numbers 9. needle should be of 16 gauge, ul tra thin walled and straight with sharp regular margins and bevelled tip to ensure ultimate donor comfort. 1 0. needle should be rust proof, hermetically sealed and tightly fixed with hub covered with sterile guard. 11 . external port should be tamper proof and should not be re-capped. 12. cpda/cpda-1 (49 ml i.e. 14 ml/10 0ml of blood) should be used as anticoagulant and preservative solution. 13. anticoagulant solution should be clear & colourless and manufacturer has to supply anticoagulant quality check certificate. 14. the expir y date should be at least 2 years from the date of supply of blood bags to the consignee. 15. item should b e isi/iso 3826/european ce compliant. ai(2024-25) , item code no.s-60054, sl no.603 ]
Tender For providing of custom bid for services - mrpl tender 3300011838 service code 1056149 certification audit for migration and issue of certificate for first year bidder has to quote lumpsum amount including gst,custom bid for services - 2nd service code 1056150 first surveillance audit of iso for second year bidder has to quote lumpsum amount including gst bidder has to quote lumpsum amount including gst,custom bid for services - 3rd service code 1056151 second surveillance audit of iso 270012022 for third year bidder has to quote lumpsum amount including gst