Tender For supply of dc ammeter , ac ammeter , dc voltmeter , ac voltmeter , wattmeter , power factor meter , rheostat , rheostat double tube , wire striper , screw driver , plier , nut driver , pop spaner , line tester five hundred volts , cable cutter , pvc batten , pvc conduit , pvc casing and caping batten , hydraulic crimping tool , hand crimping tool , mcb single pole , dpmcb , module box for fitting of switches sockets etc , switches , fan regulator , socket , angular holders , main switch dpmcb , changeover switch , elcb , rccb , two way switch for module fitting , ordinary electric bell , relay for bell circuits , wooden board , acsr wire dog conductor for making joints practice , g i pipe earthing with all accessories , g i plate earthing with all accessories , electric iron , water heater , heat convector , desert cooler , room heater , mixer , blender , drilling machine , pvc bends , pvc junction boxes , clamp on meter , soldering iron station , lamp , variac , dc regulated power supply , kcl kit , kvl kit , galvanometer , conversion of galvanometer into ammeter and voltmeter kit , wheatstone bridge , capacitor , lead acid battery , lithium ion battery , battery management system and controller for electric scooty , induction coil air core iron core , rl rc and rlc kit for active reactive and apparent power , load bank , current transformer , potential transformer , earth tester , megger insulation tester , energy meter , inductive load bank , capacitive load bank , patch cords , cro probes
Tender For supply of spares for 02 nos float and boost chargers for 220 vdc and 48vdc battery bank at power house c c - 16a ammeter selector switch for main input current selection , 16a voltmeter selector switch for main input voltage selection , 10a tp ac 2 way without off auto or manual mode selection for float and boost chargers , 16a sp dc 2 way without off switch for float rectifier or load bus and boost rectifier or battery voltage selector switch , 16a sp ac 2 way without off auto c or o mode or manual boost mode selection for charger , 10a tp dc 2 way without off for boost charging of battery set 1 or 2 selection , 225a dc coil operated emergency contactor coil 220v dc auxi 1no , 185a dc coil operated contactor for boost charging battery set 1 coil 220v dc auxi 2 nc , 63a dp dc on or off switch for load isolation , 40a dc coil operated emergency contactor coil 48v dc auxi 1no , 65a dc coil operated contactor for boost charging battery set 1 coil 48v dc auxi 1 nc , filter capacitor for ripple suppression for float and boost chargers rating 100 v 2200 uf , dc to dc convertor 48v dc to 24 v dc 5 amps , 4 channel relay boards for contact multiplication of card mounted protection relays , electronic card module for avr and current limit for float charger auto and manual mode , electronic card module for avr and current limit for boost charger auto and manual mode , electronic card module for float and boost rectifier fuse fail and filter fuse fail , protection module for various fault detection and annunciation , blocking diode for float and boost charger rating 70a i avg piv 800 for fcb mode on k3 heat sink , 80 percent blocking diode stud type rating 70a i avg piv 800 on k3 heat sink , latching resistor for rectifier. 250 ohms 50 watts for float and boost chargers , 10k 1w potentiometer for auto or manual voltage adjust in float charger , 10k 1w potentiometer for auto or manual current adjust in boost charger , 2ph control transformer for power supply of avr cards prim 415 v sec 16 0 16 v ac 400ma , 3ph control transformer for synchronising of avr cards. pri 415 v sec 16 0 16 50ma , 3ph control transformer for ac u or v pri 415 v 3 phase sec 0 16 vac 1 phase 250 ma , 2 0fi control transformer for fan control supply prim 415 v 2 phase sec 190v ac 50va , scr stud type 70a with heatsink loose module only , diode free wheeling stud type 70a with heatsink loose module only , digital ac ammeter 48 x 96 sq mm class 1 ct ratio 25 or 1a auxiliary voltage 24v dc , digital ac voltmeter 48 x 96 sq. mm class 1 range 0 500v ac auxiliary voltage 24v dc , digital dc ammeter for float boost chargers and 80percentage cell tap 48 x 96 sq mm class 1 75mv dc with shunt auxiliary voltage 24v dc , digital dc voltmeter 48 x 96 sqmm class 1 range 75mv dc auxiliary voltage 24v dc , digital dc charge or discharge ammeter for battery 48 x 96 sq mm class 1 range 75mv with shunt auxi 24v dc , transportation charges for material
Tender For supply of supply of 360 deg outer clear lens,supply of 180 deg filter yellow left,supply of 180 deg filter yellow right,supply of 180 deg filter clear left,supply of 180 deg filter clear right,supply of 180 deg filter red left,supply of 180 deg filter red right,supply of 5 kv grade 16 sqmm airfield cable,supply of 5 kv grade 6 sqmm airfield cable,supply of 2x4 sqmm, 1.1 kv grade, unarmoured secondary lead cable,supply of 100w grade 5000v 50 hz individual lamp series type isolatingtransformer,supply of 16a rating porcelain connector suitable for ama make hirl fitting,supply of 200w, 6.6a bi pin halogen lamp,supply of 150w, 6.6a bi pin halogen lamp,supply of 150w, 6.6a bi pin halogen lamp,supply of bi-pin holders suitable for 150w and 200w lamp,supply of 220w, 0.7a led electronic driver converter,supply of 40w, 0.7a led electronic driver converter,supply of led flood light fixture having system lumen output not less than 44000 lumens,supply of led flood light fixture having system lumen output not less than 24000 lumens
Tender For corrigendum : supply of misc em items d d--non - modular piano type domestic electrical switches as per is 3854 (q3) , piano type non modular domestic fan regulator as per is 11037 (q3) , piano type modular domestic electrical sockets - is 1293 (q3) , modular piano type domestic electrical switches as per is 3854 (q3) , electrical plugs (v2) isi marked to is 1293 (q2) , bayonet lampholders (v2) isi marked to is 1258 (q2) , piano type non modular domestic electrical sockets - is 1293 (q3) , modular fan regulator 2 module , celing rose , switch 5 6 amp 2 way , switch socket combined 6 amp , switch socket combined 16 amp , heat shrinkable straight through 95 sqmm x 3 core, 11 kv end terminatrion. , heat shrinkable straight through 185 sqmm x 3 core, 11 kv end terminatrion. , heat shrinkable straight through 120 sqmm x 3 core, 11 kv end terminatrion. , heat shrinkable cable joint 10 sqmm 2 core , heat shrinkable cable joint 16 sqmm 2 core , heat shrinkable cable joint 10 sqmm , heat shrinkable cable joint 16 sqmm , heat shrinkable cable joint 25 sqmm , heat shrinkable cable joint 35 sqmm , heat shrinkable cable joint 50 sqmm , heat shrinkable cable joint 70 sqmm , heat shrinkable cable joint 95 sqmm , heat shrinkable cable joint 120 sqmm , heat shrinkable cable joint 150 sqmm , heat shrinkable cable joint 185 sqmm , heat shrinkable cable joint 240 sqmm , condensor 2. 5 mfd , condensor 4 mfd , ding dong bell , buzzer electric , insulationtape 15 mm x 25 mtr long , insulationtape 20 mm x 25 mtr long , insulation tape 25 mm x 25 mtr long , ht tape , pvc casing caping 20mm , pvc conduite pipe 25mm , pvc conduite pipe 32mm , pvc saddle clip for cable 6 mm , pvc saddle clip for cable 25 mm , heating element 2000w cup or thread type , heating element 2000w , heating element 1500w , 3 kw heating element , gasket for transformer sheet , foam for gap filling in electrical panel db and 1 ltr pkt , crc liquid for preventing corrosingn and 500 ml pkt , geyser element 2 kv , ac gang box switch socket and top with mcb 25 amp , change over switch 100 amp , change over switch 200 amp , change over switch 400 amp , contactor mnx-50 , contactor mnx-70 , contactor mnx-95 , modular surface mounted gang box 3 module , modular surface mounted gang box 6 module , modular surface mounted gang box 18 module , modular cover plate 3 module with frame , modular cover plate 6 module with frame , cotton waste , pig lead , lead acid battery 12 v 90_100 ah , lead acid battery 12 v 90_150 ah , lead acid battery 12 v 90_180 ah , thermostate for geyser , astronomical timer for street light control , compressor 220-280 v, weight 18 kg for split ac 1. 5 or 2 tr , compressor 50 plus 4 or 50 plus 6 mfd rotary type suitable for split ac 1. 5 or 2 tr , electronic pcb plate for split and window ac suitable for 1. 5 or 2 tr , solar street light ng series 40 w , magnum grand pwb , transformer oil //bid details2 / 82