Get complete information related to latest Jumper Cable Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Jumper Cable Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Jumper Cable Tenders.
Tender For supply of electrical items - supply of electrical items for wiring and cable upgradation, mcb 20 amps, single pole, mcb 63 amps,three pole, wire pvc (copper) 4.0 sq.mm, single core, wire pvc (copper) 10.0 sq.mm, single core, wire pvc (copper) 1.5 sq.mm, single core, pvc casing caping beat 38 mm, pvc casing caping elbow 38 mm, pvc casing caping tee 38 mm, pvc casing caping internal 38 mm, pvc casing caping external 38 mm, pvc casing caping beat 25 mm, pvc casing caping elbow 25 mm, pvc casing caping tee 25 mm, pvc casing caping internal 25 mm, pvc casing caping external 25 mm, pvc conduit pipe 19 mm, pvc conduit bend 19 mm, mccb 160 amps 4 pole with vertical load line db 24 way (double door), mccb 100 amps 4 pole with vertical load line db 12 way (double door), mccb 100 amps 4 pole with vertical load line db 8 way (double door), mccb 160 amps 4 pole, g frame, bi-metallic lug 150 sq. mm., ring type, bi-metallic lug 50 sq. mm., ring type, aluminium armoured,4 core,150 sq. mm., aluminium armoured,4 core, 50 sq. mm.
Tender For renovation of electrical works to install new fm transmitter at air motihari (bihar).(sh:- wiring/ rewiring with copper conductor i/c replacement of fans, fittings alongwith service connection cable)
Tender For tender for supply of attending ea set located upto 25km from dist hq incl rectification of minor fault in wiring , lubricating etc nothing extra will be paid for repeated fault within 4month of the first visit , attending ea set located between 25km to 50km from dist hq incl rectification of minor fault in wiring , lubricating etc nothing extra will be paid for repeated fault within 4month of the first visit , attending ea set located between 50km to 100km from dist hq incl rectification of minor fault in wiring , lubricating etc nothing extra will be paid for repeated fault within 4month of the first visit , attending ea set located between 100km to 200km from dist hq incl rectification of minor fault in wiring , lubricating etc nothing extra will be paid for repeated fault within 4month of the first visit , carry out b check servicing of 7.5kva to 15kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , carry out b check servicing of above 15kva to 32.5kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , carry out b check servicing of above 32.5kva to 62.5kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool n tackle etc as reqd , carry out b check servicing of above 62.5kva to 125kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , carry out b check servicing of 160 kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , carry out b check servicing of 200 kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , carry out b check servicing of 250 kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , providing and fixing of 12mm dia wire braided pvc pipe for diesel supply and return lines in existing ea set incl. testing , commissioning etc as reqd , providing and fixing of benjo and benjo bolt with washer and scew on pipe clamps at both ends for existing ea set incl. testing , commissioning etc as reqd , providing and topping up of corrosion inhibitor coolant in radiator of existing ea set incl. testing , commissioning etc. as reqd. , providing and topping up of 15w40 grade lubricating oil of recommended make in existing ea set incl. testing , commissioning etc. as reqd. , providing and fixing of 2 no. 50 sqmm copper conductor flexible cable leads each of 1 mtr length incl. lugs and battery terminals at both ends for starting battery of existing ea set as reqd. , providing and fixing of battery terminal socket set for dg starting battery incl. testing , commissioning etc. as reqd. , providing and fixing of stop solenoid valve suitable for 7.5 kva to 32.5 kva ea set incl. testing , commissioning etc. as reqd. , providing and fixing of stop solenoid valve with solenoid switch suitable for 45 kva to 125 kva ea set incl. testing , commissioning etc. as reqd. , providing and fixing of radiator fan v belt set suitable for 7.5 kva to 62.5 kva ea set incl. testing , commissioning etc. as reqd. , providing and fixing of radiator fan v belt set suitable for 75 kva to 250 kva ea set incl. testing , commissioning etc. as reqd. , providing and fixing of ignition switch or push button for ea set incl. testing , commissioning etc. as reqd. , providing and fixing of engine start key switch incl. testing , commissioning etc. as reqd. , providing and fixing of oil pressure guage for ea set incl. testing , commissioning etc. as reqd. , providing and fixing of water temperature guage for ea set incl. testin
Tender For tender for supply of attending ea set located upto 25km from dist hq incl rectification of minor fault in wiring , lubricating etc nothing extra will be paid for repeated fault within 4month of the first visit , attending ea set located between 25km to 50km from dist hq incl rectification of minor fault in wiring , lubricating etc nothing extra will be paid for repeated fault within 4month of the first visit , attending ea set located between 50km to 100km from dist hq incl rectification of minor fault in wiring , lubricating etc nothing extra will be paid for repeated fault within 4month of the first visit , attending ea set located between 100km to 200km from dist hq incl rectification of minor fault in wiring , lubricating etc nothing extra will be paid for repeated fault within 4month of the first visit , carry out b check servicing of 7.5kva to 15kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , carry out b check servicing of above 15kva to 32.5kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , carry out b check servicing of above 32.5kva to 62.5kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool n tackle etc as reqd , carry out b check servicing of above 62.5kva to 125kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , carry out b check servicing of 160 kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , carry out b check servicing of 200 kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , carry out b check servicing of 250 kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , providing and fixing of 12mm dia wire braided pvc pipe for diesel supply and return lines in existing ea set incl. testing , commissioning etc as reqd , providing and fixing of benjo and benjo bolt with washer and scew on pipe clamps at both ends for existing ea set incl. testing , commissioning etc as reqd , providing and topping up of corrosion inhibitor coolant in radiator of existing ea set incl. testing , commissioning etc. as reqd. , providing and topping up of 15w40 grade lubricating oil of recommended make in existing ea set incl. testing , commissioning etc. as reqd. , providing and fixing of 2 no. 50 sqmm copper conductor flexible cable leads each of 1 mtr length incl. lugs and battery terminals at both ends for starting battery of existing ea set as reqd. , providing and fixing of battery terminal socket set for dg starting battery incl. testing , commissioning etc. as reqd. , providing and fixing of stop solenoid valve suitable for 7.5 kva to 32.5 kva ea set incl. testing , commissioning etc. as reqd. , providing and fixing of stop solenoid valve with solenoid switch suitable for 45 kva to 125 kva ea set incl. testing , commissioning etc. as reqd. , providing and fixing of radiator fan v belt set suitable for 7.5 kva to 62.5 kva ea set incl. testing , commissioning etc. as reqd. , providing and fixing of radiator fan v belt set suitable for 75 kva to 250 kva ea set incl. testing , commissioning etc. as reqd. , providing and fixing of ignition switch or push button for ea set incl. testing , commissioning etc. as reqd. , providing and fixing of engine start key switch incl. testing , commissioning etc. as reqd. , providing and fixing of oil pressure guage for ea set incl. testing , commissioning etc. as reqd. , providing and fixing of water temperature guage for ea set incl. testin
Tender For supply of jumpercable support link assembly (stainless steel ) as per icf drg. no.lwscwac /eog-7-1-006/col 1, alt-nil and with proper bracket (as per icf drg no. aab15007) [ warranty pe riod: 30 months after the date of delivery ]
Tender For supply of set of inter vehicle couplers (double end) jumpercable assembly kit for 3 phase 08 car to 12 car conversion in bhel onboard memu rcf rake, as per edml 219, rev.nil, table 1 consisting of 09 items : 1 to 7)double end jumper assembly of a,b,c,d,g,h,&j, qty-each 01 nos. each/set., 8)potential cable - qty-0 2 nos., 9)mounting bracket assembly, qty-02 nos./set. with male harting connectors at both ends for 2.4 meters long (each cable) [ warranty period: 30 months after the date of delivery ]
Tender For removing, shifting and re-erection the electrical substation equipments from 6th berth s s to proposed location thereof inside cargo jetty area - removing & shifting of the following equipments as per tech spec. no:-1, 500 kva distributions transformer., rmu of 12 kv, 630 amps 21 ka outdoor mounted rmu unit., lt panel ( way-15), re-erection, testing & commissioning of the following equipments as per tech. spec. no. 2, 500 kva distributions transformer., rmu of 12 kv, 630 amps 21 ka outdoor mounted rmu unit, supply at site 3 core armoured ht aluminium conductor xlpe cable of 11 kv grade, following rating of the as per technical specification no. 3 a). 3c x 150. sq. mm., supply at site 4 core armoured lt aluminium conductor xlpe cable of 1.1 kv grade, following rating of the as per technical specification no. 4 a) 3.5c x 300 sq. mm., supply, installation testing & commissioning at site of following 11-way lt load point panel (as per proven design) as per technical specification no. 511 ways {2 i/c, i changeover (bus coupler), 8 o/g}., laying ht/lt armoured aluminium conductor cable 3.5/4 core up to 35 sq. mm. to 150 sq. mm. as per technical specification no. 6, through hdd, with hdpe heavy duty pipe., in existing rcc trench, hard & soft soil, supply at site following way lt distribution panel (as per proven design) as per technical specification no. 715 ways (2 i/c, 1 bus coupler, 12 o/g)., installation, testing & commissioning of lt distribution panel as per technical specification no. 8, providing & connecting following type of earth wire from earth station to equipment as per requirement as per tech. spec. no. 9, 25 x 3 mm. copper strip, 25 x 3 mm. hot dip gi strip., 8 swg gi earthing wire, supply & preparation of earthing station, tfc, chemical treated back filled compound earthing system as per technical specification no. 10a) pipe-in-pipe 50-60 mm. dia. gi type 3 mtr. depth, for transformer body earth, maintenance free, supply of 3 phase 500 kva 11/0.433 kv indoor type distribution transformer as per technical specification no. 11, installation, testing & commissioning of 500 kva 11/0.433 kv indoor type distribution transformer as per technical specification no. 12, supply of tpn double door ip 42 db 4 ways distribution board as per technical specification no. 13, fixing of tpn double door ip 42 db 4 ways distribution board as per technical specification no. 14, supply of following type of mcb as per technical specification no. 15, 40a tpn mcb with 10ka breaking capacity, 32a sp mcb with 10ka breaking capacity, fixing of tpn/sp mcbs with 10 ka breaking capacity as per technical specification no. 16, providing & fixing of surface wiring with 2 x 2.5 sq. mm. copper conductor with pvc insulated (single phase and neutral) for single phase sub-circuit from the db/mcbs to the switch board as per technical specification no. 17, providing and fixing surface wiring with 1.5 sq. mm. copper conductor for light /tube point with pvc insulated single core standard copper conductor wire as per technical specification no. 17, providing and fixing surface wiring for 20a & 10a, 240 volt, 50hz power point as per technical specification no. 19, supply & installation of surface mounted 20 watt led tube light luminary complete with batten as per technical specification no. 20, supply at site 300mm sweep exhaust fan as per technical specification no. 21, fixing of 300mm sweep exhaust fan as per technical specification no. 22, supply of heat shrink straight through joint kit for 11kv, 3c x 150 sq.mm h.t xlpe cable as per technical specification no. 23, fixing the heat shrink straight through joint kit for 11kv 3c x 150 sq.mm h.t xlpe cable as per technical specification no.24, supply of heat shrink long sleeve & boat, suitable for rmu end termination kit (indoor type) for 11kv 3c x 150 sq.mm h.t xlpe cable as per technical specification no. 25, fixing of heat shrink long sleeve & boat, suitable
Tender For complete rewiring of different union offices at nts colony barkakana. - wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. group b., supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connection but excluding modular plate etc. as required ., supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 a modular socket outlet and 5/6 a modular switch, connections etc. as required., supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 a modular socket outlet and 15/16 a modular switch, connections etc. as required., wiring for circuit/sub main wiring along with earth wire with the following sizes of frls pvc insulated copper conductor single core cable in surface/recessed pvc conduit as required. 2x2.5 sq.mm +1x2.5 sq. mm earth wire., wiring for circuit/sub main wiring along with earth wire with the following sizes of frls pvc insulated copper conductor single core cable in surface/recessed pvc conduit as required. 2x4 sq.mm +1x 4 sq. mm earth wire., wiring for circuit/sub main wiring along with earth wire with the following sizes of frls pvc insulated copper conductor single core cable in surface/recessed pvc conduit as required. 2x6 sq.mm +1x 6 sq. mm earth wire, supplying and fixing 5 amps to 32 amps rate 240 v c series mcb suitable for inductive load of following poles in the existing mcb db complete with connections testing and commissioning etc as required. single pole., supplying and fixing 5 amps to 32 amps rate 240 v c series mcb suitable for inductive load of following poles in the existing mcb db complete with connections testing and commissioning etc as required. double pole., supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 8 way double door., supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 a "c" curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required., supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc. as required., supplying and fixing brass batten /angle holder including connection etc. as required., supplying, installation, testing and commissioning of following capacity tpn tap off box made of 1.6 mm thick sheet steel enclosure duly painted with power coating on existing rising mains complete with tpn disconnector fus and hrc fuses, connections, earthing etc as required. 32 amp tpn, earthing with copper earth plate 600 mm x 600mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salt as required., providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connection etc. as required., providing and fixing of recessed mounting led round panel light fitting (18 watt)., total impact of gst for the purpose of ctc