Get complete information related to latest Kitkat Fuse Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Kitkat Fuse Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Kitkat Fuse Tenders.
Tender For supply of screen plate upper mat-c45 hardness-250bhn with ht fastners , screen plate lower mat-c45 hardness- 250bhn with ht fastners , suspension bar of tkii-make crusher of model-rhm 1224 , breaker plate, with required ht fastners size-900x415x46, mat-mn steel for tkii make crusher model-rhm-1224 dia 1220x2390 mm,48 inch x 94 inch , kick off plate,spare of crusher,with required ht fasteners, hx hd bolt with nut m24x70, ref-tkii drwg no- r.a09.800.48.50 ,item no-25 , lock plate of suspension bar for tkii make crusher model-rhm 1224 dia,48 inch x94 inch,drg no-r.a09.200.48.50,with ht fastners
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - wt-5145g - elect fuel - preventive maintenance contract of ht/lt motors along with its module/breaker, cable tray cleaning work, cleaning of 6pt 6 kv/415 v bus-bar panel..
Tender For tender for supply of periodical maintenance and operation of electrical and mechanical installations involving operation , repairs and maintenance , attending to complaints/faults/ breakdowns and taking rectification action , ensuring serviceability/satisfactory working condition of the systems , carrying-out preventive maintenance , maintenance of records/ documents etc. under this contract on all working days including saturdays , sundays and holidays as per tender specifications , terms & conditions by providing/engaging following minimum number of man power i/c reliever. (a) highly skilled (sr. supervisor) - 1 nos. (b) highly skilled (supervisor) - 1 nos. (b) skilled data entry operator - 1 nos. (c) skilled technician - 14 nos. i/c relievers (d) unskilled helper - 14 nos. i/c relievers total minimum manpower i/c reliever- 31 nos. note- relievers shall do duty of electrician//helper as per site requirement. , carriage of diesel (4 drums 200 ltr each) from petrol pump (any petrol pump among located in kushinagar as decided by eic-aai) to the sub station (dg set room) which includes hiring of vehicle loading & unloading of empty and oil filled drums at site. note - empty drum will be provided by aai. , servicing of l&t make , model u-power omega air circuit breaker 630/800 a through l&t service engineer / l&t authorized service engineer including carrying out of following works- racking out & removal of acb from electrical panel , cleaning all parts for dust deposits foreign particles etc , degreasing the various parts of acb. cleaning all parts with cleaning agents such as crc 2-26 checking the various relay/protection settings and other setting of acb contacts , releases etc , checking the hardware for wear & tear , checking of termination & tightness , checking for all hardwares for its presence , replacement of spares / accessories for defective / worn out items (supply of spares / accessories required for healthiness of acb are in aai scope) , regreasing of the acb parts as recommended by oem , refixing the acb , testing and observance for normal operation of acb complete as required. note - service report to be submitted in l&t letterhead / l&t authorise service dealer letter head. , one time servicing , maintenance , testing , overhauling of complete out door type package/ compact sub-station of m/s c & s make through oem service er. or oem authorised dealer /service er.only as per the oem recommendation and scope of work of tsc/ scc of the contract. pss is comprising of following- ht panel - 12kv , 630 a , 21ka/3sec , 2way non extensible sf6 insulated rmu comprising of 01 nos. 630a manual load breaker switch and 01 no. 630a manual vaccum circuit breaker. transformer - 11kv/0.433kv , 400 kva oil type transformer -01 nos. lv componenet - 4 p , 630a , drawout acb - 01 no. 3p 400a mccb for capacitor panel capacitor panel - apfc 200kvar capacitor panel- 01 nos. pss is comprising all above i/c metering , relay etc complete. oem service er. has to submit the relay calibration report along with service and maintenance report of transformer , rmu , ht & lt panel and capacitor panel i/c healthiness report after service and other report if any as per oem recommendations complete. , carriying out the dehydration of transformer oil of 400 kva transformer (make - kotson) in 400 kva c &s pss at site i/c transportation of dehydration machine , di-electric strength test (bdv value) of oil before and after dehydration at site and submisstion of report as per requirement. note - the transformer having capacity of 330 ltrs of tranformer oil. , supply of new transformer oil conforming to is-335 in non-returnable barrel as per requirement. , one time servicing , maintenance , testing , overhauling of complete outdoor type package/compact sub-station of m/s sudhir power make through oem service er or oem authorised dealer /service er.only as per the oem recommendation and scope of work of
Tender For annual repair and comprehensive maintenance of iiest at shibpur, howrah-711 103 during 2025-26. (s.h.:- serving and overhauling of vcb, transformer, apfc & 6.6 kv ht breaker including dehydration of 630 kva oil type transformer etc. complete as reqd.)
Tender For corrigendum : supply of 11 mtr long 150 x150 gi pole , 11 kv pin insulator , 11 kv hw fitting 45 kn , 11 kv v cross arm , 11 kv disc insulator 45 kn polymer , 11 kv 1 core 100 sqmm xlpe conductor , 100x50x6 gi ms chanel , 75x40x6 gi ms chanel , 50x50x6 gi ms angle , pg clamp for 100 smm2 conductor , lightning arrester 12 kv,10ka , road crossing guarding , 3.5 c x 95 smm xlpe insulated , 63 kva transformer , lt db box with mccb and kitkatfuse 63 kva , ab switch 11 kv,200 a 3 pole,50hz , h.g fuse 11 kv,200 a 3 pole with pl , gi pipe earthing 3 mtr long , hdpe pipe 8 inch 10 mtr , 25 x 6 mm gi flat , 50 x6 gi flat , earthing material , earthing of support , danger plate , anti climbing device of gi barbed wire , gi nut,bolt and washer of , all cable lugs , 10 core 2.5 sqmm cu control cable armoured , fish plate , ht stay set complete , ht stay insulator , 7 per 10 swg stay wire 10kg per stay , ht stay clamp , black yellow paint
Tender For corrigendum : supply of breakers - 11 kv ct swbd. incomer-breaker retrofit , 11 kv ct swbd. motor feeder retrofit , 11 kv ct swbd. trafo. feeder retrofit , 11 kv ct swbd. seht feeder retrofit , 11 kv ct swbd. bus-pt panel retrofit , installation testing commissioning of switchgear components for refurbishment of abb make 11 kv switchbaord at coastal terminal ht substation including retrofitting of existing sf6 circuit breakers with new vacuum circuit breakers vcbs panel control wiring modifications for numerical relay retrofit and conversion to 110 vdc auxiliary supply as per tender specifications scope of works and directions of engineerincharge
Tender For corrigendum : providing of custom bid for services - 9040c26a92 servicing overhauling of ht breaker panels verticals at haldia refinery township