Tender For supply and installation of set of work-station for chemical & metallurgical labtestingequipment stand as per annexure attached. [ warranty period: 30 months after the date of delivery ]
Tender For renewal of insurance policy no 54080211258700000006 and 54080246250100000006, for furnitures, fixtures, fittings other office equipment, plan, machinery that includes labtestingequipment or machinery at bharatpur house, civil lines, mg road, agra
Tender For enquiry for calibration of various equipment's of gwalior testinglaboratory gwalior, mpmkvvcl. ,digital temperature controller (conditioning chamber) ,digital humidity controller (conditioning chamber) ,ac high voltage test kit (digital ac kv meter) ,ac high voltage test kit (digital ac ma meter) ,digital caliper ,digital caliper ,digital external micrometer ,digital external micrometer ,digital coating thickness gauge ,digital earth resistance tester ,digital weighing balance ,capacitive voltage divider
Tender For supply of 5 kv calibration box check resistance readings with test voltages up to 5 kv d.c. a calibration certificate is provided with each. nominal resistance values: 10 m , 100 m , 1 g & 10 g , calibration accuracy: 1% nominal value accuracy: 2% voltage coefficient: 1ppm/v calibration temperature: 20?c (68 degrees f) temperature coefficient: 250 ppm/ degrees celsius (139 ppm/degrees f) shelf stability typically: 0.5% per year operating temperature: 5 degrees celsius to 40 degrees celsius (41 degrees f to 104 degrees f) storage temperature: -20 degrees celsius to 60 degrees celsius (-4 degrees f to 140 degrees f) operating humidity: 60% rh maximum. safety: meets iec1010-1 (1995) or latest with zero adjustment/calibration bar for battery impedance tester.(warranty period : upto 12 months from the date of delivery.) [warranty period: 12 months after the date of delivery ]
Tender For supply of 5 kv calibration box check resistance readings with test voltages up to 5 kv d.c. a calibration certificate is provided with each. nominal resistance values: 10 m , 100 m , 1 g & 10 g , calibration accuracy: 1% nominal value accuracy: 2% voltage coefficient: 1ppm/v calibration temperature: 20?c (68 degrees f) temperature coefficient: 250 ppm/ degrees celsius (139 ppm/degrees f) shelf stability typically: 0.5% per year operating temperature: 5 degrees celsius to 40 degrees celsius (41 degrees f to 104 degrees f) storage temperature: -20 degrees celsius to 60 degrees celsius (-4 degrees f to 140 degrees f) operating humidity: 60% rh maximum. safety: meets iec1010-1 (1995) or latest with zero adjustment/calibration bar for battery impedance tester.(warranty period : upto 12 months from the date of delivery.) [warranty period: 12 months after the date of delivery ]