Get complete information related to latest Laboratory Extractor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Laboratory Extractor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Laboratory Extractor Tenders.
Tender For corrigendum : 21/2024-25 purchase of laqshya instrument - purchase of instrument ( laqshya), radiant warmer- technical specification of radiant warmer with baby bassinet a radiant warmer is used to keep the patient s core temperature stable at 37 o c. it should be microprocessor controlled radiant warmer with manual and servo options. it should have facility to display both skin and air (ambient) temperature separately.. it should have audiovisual alarm facility for overheating beyond set temperature range. it should have alarm facility for patient temperature less than or greater than the required temperature i.e. above or below the set range. it should rotate and swivel in different direction, so as to allow taking x-ray. the light should be dazzle free. it should have alarm for power failure. it should have alarm for heater failure and auto cut off for high temp. it should have alarm for probe failure. it should have time out alarm in manual mode. it should have facility to auto reset the system in case of hang up caused by power fluctuation. it should have manual setting for high and low alarm setting. in servo mode, the heater output should be controlled to maintain the baby at the required set temperature. in manual mode, the heater output should be directly controlled by a setting on the front panel should have a facility to lock the keyboard to avoid unwanted user. the desired temperature range from 25 to 40 degree c. the resolution should be 0.1 degree c halogen based observation light should be provided for observing the baby. it should be mounted on a pole with sturdy base with lockable castors power supply: power input to be 220-240 vac, 50hz fitted with indian plug. certificate of calibration and inspection from the factory. warranty: comprehensive warranty for 5 years after warranty documentation: user, technical, maintenance manuals to be supplied ce, iso certified , fetal doppler - technical specification of fetal doppler should be compact, table type and light weight. large lcd display for display of fetal heart rate. back light for better visibility display signal quality, low battery, etc., high sensitivity doppler probe of frequency 2.0 mhz ultra sound intensity 10mw/cm2. built-in speaker with output not less than 1.0w should work on rechargeable batteries with minimum battery time of 300minutes. battery charger and spare set of batteries aa type to be supplied. volume control facility and audio output for ear phone should be available. heart rate range should be from 50 to 240 b pm with accuracy of + /-2% should be water proof body. should have facility for fhr data transfer to pc. doppler probe should be light weight with holder facility when not in use. should be supplied with carrying case. machine should be iso mark, baby digital thermometer - technical specification of baby digital thermometer range 0.1 to 1000 degree centigrade measurement mode- min, max, average, differential, dual temperaturereading measurement unit- degree centigrade, degree fahrenheit,kelvin temperature probe with connecting cable relative humidity10 to 90% rh non-condensing ip rating- ip 40 g) probe response time 2-3 seconds it should be who & unicef standards, fetoscope - technical specification of infant fetoscope should be 135 75mm weight should be up to 350gm should be 40cm h20 presser limiting valve inspiratory resistance should be 5cmh2o (at 50l/min), delivery trolley/patient stretcher trolley- technical specification of patient stretcher trolley overall size: 1905mm l x 710mm w x 660mm to 910 mm h. stretcher dimension 1830 mm l x 555 mm w. two section top. height adjusted by foot operated maintenance free hydraulic pump. height adjustment shall be obtained by hydraulically operated mono block type linear actuator pump foot operated actuation having stroke of 140 +/- 5 mm, push force 10 kn at 270 bars, number of complete pump stroke 22 to 24 for full stroke length x-ray permeable removable stretcher, backrest raised on
Tender For supply and installation of miscellaneous items - led notice display board height (min)(mm)-609.6, length(min)(mm)-1920, led pitch (max) (mm)-10, led display board type-single,led colour-red,led type-smd,language-english; regional,unicode support-utf-8,number of display lines]-2,type of displayed infornation-static + scrolling both,viewing angle-horizontal 160 deg or higher & vertical 130 deg or higher,viewing distance (meter)-15,automatic brightness control-yes,led brightness(cd/m2)--4001-5000,pixel pitch (mm)-10,minimum pixel density (dots/meter2)-5000,maintenance-rear,duty cycle-16x 7,life span (hours)-50000,construction-display system,it is consisting of led display board + embedded controller,cabinet-steel/alluminium box duly powder coated,type of installation-outdoor,wi fi connectivity-yes, if yes, type of wi fi connectivity,802.11 b/g/n,usb port-1,gsm connectivity-yes, if yes, cellular data support-4g/lte,input voltage (vac)-110-240,maximum power consumption (watt)-300,weight (kg)-50,on site oem warranty (year)-1, pa- audio sound system with trolly :- system type-1 way,built in uhf receiver-no,number of wireless microphones-2,bluetooth connectivity-avalilable,built in memory (gb)-0,number of channels-1,warranty (years)-1, sanitary napkins vending machine :- type of machine-automatic,operating features-coin operated/free,multiple coins accepted-yes,number of selection options-2,accessibility for free vending utility service-na,type of loading-spiral,maximum storage capacity (nos)(nos)-25-50,material of the outer body-mild steel(ms),built-in charger-no,mode of function-stand alone,operating power source-electronic,battery backup time (hrs)-na,thickness of ss/ms sheet (mm)-1.2,thickness of frp/plastic sheet (mm)-1.2, sanitary napkins incinetator machine with smoke control unit :- stand provided-yes, thickness of thermal insulation material (mm)-40 millimeter, thickness of ms/ss sheet of burning chamber (internal) (mm) (min)-3 millimeter, machine weight(kg)-51-250, thickness of door including insulation (mm)-40 millimeter, flexible emission outlet pipe dia (mm)-76 millimeter, material of housing cabinet (external)-mild steel(crca) sheet, material of burning chamber (internal)-stainless steel sheet of ss-304 grade, material of thermal insulation-high density ceramic board, temperature indicator provided-yes, minimum burning temperature (degree c)-800, burning capacity per day (number of napkins)-1000-1250, burning capacity at a time (number of napkins)-26-50, burning time of full capacity napkins/pads (minutes) (max)-35 minutes, automatic digital controller for time-yes, automatic digital controller for temperature-yes, type of scu (smoke control unit)-top mounted, material of housing of smoke control unit (scu)-mild steel(crca) cabinet, both carbon control and foul odour control chambers for filteration of smoke emission-yes, number of filters in carbon control chamber-one, type of filters in carbon control chamber-ceramic blanket as a filter, number of filters in odour control chamber-one, blower rpm-1800, warranty in years (option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue)-1, wall mounted automatic fire extinguisher:- extinguishing media-powder based (as per is 4308), expellant medium-n2 based, extinguishing agent of powder based fire extinguisher-abc map90, discharge mechanism-automatic, additional requirement (hint: select na if not applicable)-na, cylinder/vessel material-mild steel, valve material-stainless steel, internal coating-epoxy powder coating, external coating-epoxy polyester powder, powder based fire extinguisher capacity (in kg) (hint: select na if extinguishing media is not powder based)-6,7,8&9, clean agent based fire extinguisher capacity (in kg) (hint: select na if extinguishing media is not clean agent)-na, fitted with heat sensor quartzoid bulbs with sprinkler heads-2, class of fire for which fire extinguisher is
Tender For procurement of various laboratory testing equipments to meet requirement of laboratory of geri for the year 2023-2024 - air conditioner 2 tonne capacity, compression testing machine-500 kn - digital pace control compliant with is 14858 and is 516 for testing cement mortar cubes and bricks thermo hygrometer with clock air conditioner 2 tonne capacity, low tempereature water bath chamber size - 300 x 250 x 200 mm and chamber volume 20 litres with temperature accuracy- 0.5 c and temperature range-5 c to 50 c
Tender For purchase of equipment - purchase of equipment: high rpm centrifuge machine specification, 1.model: table top2.type: low volume high speed3.acceleration profile- 94.no.of programmes 995.cfc free refrigerator system6.declaration profile 9 & coasting7.display lcd8.calibration window on lid for speed9.control communication digital10.self diagnostics error11.choice of rpm/rcf setting12.parameter setting switches feather touch13.temperature display - c/ f14.emergency and protection and auto shutdownrotor head: 1.angle head (polypropylene tubes) 2.capacity - (8x50ml and 12x15ml)3.container plastic4.maximum speed 20000 rpm5.max rcf -37570g
Tender For tender for the supply of equipments of various trades for govt. industrial training institutes of madhya pradesh - name of the tools, 3- point d.c. starter, 4- point d.c. starter, a.c. ceiling fan 68-watt, 230 v, ac table fan 68-watt, 230 v, ac energy meter (single phase, 10 a, 240 v induction type), ac energy meter (three phase, 15 a, 440 v induction type), a.c. voltmeter m.i. analog, portable box type housed in bakelite case, ammeter (ac 0 - 1 a), ammeter (ac 0 - 25 a), ammeter (ac 0 - 5 a), ac starters (3 phase), ammeter (ac 0 - 500 ma), ammeter mc analog, portable box type housed in bakelite case 0-5 a, ammeter mc analog, portable box type housed in bakelite case 0-25 a, battery charger 0 - 6 - 9 - 12 - 24 - 48 v, 30amp, brake test arrangement with two spring balance rating 0 to 25 kg, bus bar with brackets, cables, capacitors- electrolytic ceramic polyester film variable dual run, current transformer 415 v, 50hz, ct ratio 25 / 5 a, 5va, dc power supply 0 - 30 v, 5adc regulated power supply, digital ic trainer, digitalmultimeter, digital wattmeter, discrete component trainer, earth electrode, earth plate 60cm x 60cm x 3.15mm -copper plate, 60cm x 60cm x 6mm -gi plate, earth leakage circuit breaker (elcb ) and residual current circuit breaker (rccb), electric induction plate 1500 watt, 240v, electric iron automatic - 750 w, 240 v, electric kettle 1500 watts, 240v, frequency meter (45 to 55 hz), function generator, fuses hrc glass, rewire type (assorted type), geyser (storage type) 10 litre, growler (single phase, adjustable jaws, testing armature with ampere meter and testing probes), immersion heater 1500 watt, 240v, inverter with battery 1 kva with 12 v battery input-12 volt dc, output-220 volt ac, kilo wattmeter (analog), knife switch dpdt fitted with fuse terminals 16 amp ,440v, knife switch tpdt fitted with fuse terminals 16 amp, 440 v, laboratory type induction coil (1000 w), linear i.c. trainer, load bank (lamp/heater type) 6 kw, 3phase, lux meter, magnetic flux meter-(0 - 500 tesla), molded case circuit breaker (mccb )- triple pole, 440v, 100amps, megger (digital - 1000 v) - analog type insulation tester (megger), milli voltmeter-(center zero analog) 100 0 100 mv, miniature circuit breaker 16amps (mcb/ tpn)., mixture & grinder with all accessories and attachments 750 w, 240 v, motor pump set (1 hp, 1 phase, 240 v), ohm meter; series type, portable box type analog, ohm meter; shunt type, portable box type analog, oil testing kit: -, oscilloscope dual trace 20 mhz, out side micrometer (manual) 0 - 25 mm least count- 0.01mm, phase sequence indicator (digital) 3 phase, 415 v, plug socket piano switch lamp holder 230 v, 5 a, potential transformer, power factor meter (digital) 440 v, 20 a, rheostat (sliding type) 0 - 25 ohm, 2 amp, rheostat (sliding type) 0 - 300 ohm, 2 amp, rheostat (sliding type) 0 -1 ohm, 10amp, rheostat (sliding type) 0 -10 ohm, 5 amp, series test lamp 230v, 60w, single phase variable auto transformer 0 - 270 v, 10amp (air cooled), solar panel with battery -18 watt, soldering iron (25 w changeable bit) 230 volt, soldering iron (65 w changeable bit), soldering iron (120 w changeable bit), soldering iron temperature controlled 50-watt, 230 volt, tachometer analog type - 3000 rpm, tachometer digital photo sensor type - 10000 rpm, thermometer (digital) 0 c - 150 c, tong tester / clamp meter 0 - 100 a (digital type), various electronic components (assorted type), various lamps, voltage stabilizer, washing machine semi-automatic - 5 kg, wheat stone bridge with galvanometer and battery, ac motor (series type -1 hp), ac motor (phase-wound slip ring with starter 5 hp , 3 phase), three phase ac squirrel cage induction motor, ceiling fan coil winding machine - 250v, 50 hz, 1- , with speed control, dc generator (compound type), dc generator (shunt type with control panel), dc motor (compound type with starter), dc generators compound type :-, dc generators series type :-, dc generators- shunt type :-, dc moto
Tender For instruments - adapter for ultrasound digital fetal doppler, 1 no., 4, adult colonoscope, 1 no., 8, aluminum walker adjustable, 1 no., 12, artery forcep 6" curved, 1 no., 16, autoclave vertical: model : ac123 , lab tech -should be fully automatic vertical autoclave for total destruction of all living microorganisms-pressure adjustable from 10psi to 20psi with an accuracy of +/- 1 to 3 psi, with automatic pressure control switch-outer and inner chamber made up of stainless steel-size of the inner chamber:- 50 x 75 cm (diameter x depth)-should be providing 2 carriers of stainless steel. size of the carriers should be 35-40 x 30-35 cm ( x d)-should be provided with silicon/ rubber/ neoprene gasket-lid should be stainless steel and should be fitted with pressure gauge safety valve manual exhaust valve vacuum breaker ports of calibration check-all the hinges should be of stainless steel-should be provided with stainless steel heated cover stand-drain valve at bottom for draining the water-electrically heated-micro processor controller based system to provide digital display of cycle processes like temperature, pressure-should be provided with low water level alarm and cut off-automatic pressure control switch- to cut off the current from the heating elements, when the desired/ set pressure value level is attained inside the chamber and restarts the mechanism once the pressure inside the chamber falls from the desired level-should be fixed with chart and data recorder-iso/ ce marked -should provide test certificates, calibration certificate and traceability certificates for temperature and pressure gauges-the downtime of the equipment must not be more than 10 days annually and system must be made functional within 48 hours of breakdown and in case of such incident the period of breakdown will not be counted while calculating warranty or cmc period. if the downtime during any year is more than 10 days a penalty at the rate of 0.1percent of the cost of the equipment will be levied for each extra day of downtime.-operation manual with user demonstration video cd (with sop in guajarati), 1 no., 20, b.p. instrument digital, 1 no., 24, binocular microscope, 1 no., 28, bolster size large, 1 no., 32, bp instrument (mercury), 1 no., 36, c p chair (wooden + metal), 1 no., 40, centrifuge machine, 24 tube digital display & 5000 rpm, 1 no., 44, chital forcep 10", 1 no., 48, cold light source cable, 1 no.
Tender For corrigendum : supply of veterinary instruments and equipments - allis tissue forceps (20 cm.), artery forceps curved (15 cm ), artery forceps straight (15 cm ), forceps s.s. (20 cm), forceps s.s.(15 cm), haemostat straight s.s.(17.5 cm), haemostate curved s.s. (15 cm. ), mayo s scissors curved isi (s.s. 15cm), mayo s scissors straight isi (s.s. 15cm), scissors straight s.s.(12.5 cm), scissors straight s.s.( 17.5 cm), surgical gloves (standard), surgical mask (standard), suturing needle (assorted size) (traumatic/atraumatic cured/st.), suture thread silk/ nylon (10 mt. reel no.100, 0, 1, 2, 3), chromic cat gut (100, 0, 1, 2, 3 no.), needle holder s.s.(15cm), instrument trolly, dressing drum s.s. round 20 gauge (height 30cmx30cm dia.), b.p. blades (no. 22, 23, 24, 11, 12, 13,14, 16, b.p. handle s.s.(no. 3 ), b.p. handle s.s.(no. 4), kidney tray s.s.(15 cm length), tray small ss (250mmx300mm), hypodermic needle (15 x3/4"), hypodermic needle (18 x3/4"), vaccutainer with needle (with vacuum, 10 ml and needle of double bewell 16 no.), electrcally operated needle and syringe destroyer. destruction rate max. 1 minute per needle of 1.6 mm thickness with 80 mm length. min. 350 cutted hubs of syringes with needle burnt residue., bloodless castrator for small animals 9 (made of special high carbon steel coated for protection against rust formation), castrator imported, i/v fluid stand (s.s.), intra venous set (disposable 0 standard) ), scalp vein set (21 no. 0 22 no.), electric dehorner (30 cm length), trocar canula for sheep s.s.(15 cm), teat syphon (ss), drenching bottle (large) (metal 500 m), drenching bottle (small) (metal 200 ml), doctor coat tericot (free size), plastic apron, macentosh sheet (double colour), rubber arm sleeves with latex gloves (no. 9), gum boot, dog muzzle (assorted size), dog nail cutter (standard), measuring cylinders (50 ml graduated borosil glass ), measuring cylinders of (100 ml graduated borsil glass ), medicine carry bag (nylon 600 dpu coated padded, multipocket for medicine and surgical equipments ), jar with lid ss (2 kg. capacity), jug ss (2 ltr. cap.), thermos s.s. double insulated (1 ltr. cap., 30cm length, 7.5cm mouth dia with soulder carrying strap.), bucket ss (12 ltr capacity), california mastitis kit, centrifuge machine (bench top) for general purpose, canopy tent with carrying bag. frame made of steel powder coated pipe (23 gauge) 0 tetron cover (waterproof) with two folding chairs and one folding table, vaccine carrier (1.6 lit capacity with 4 ice packs), microscope binocular, autoclave electric, calf puller ss 316/304., animal catching device, cold boxes vaccine storage capacity 20 ltr. weight fully loaded 43.3 kg. empty weight 17.5 kg. external surface material plastic, internal lining material plastic , insulation material polyurathene, insulation thickness 110 mm,, refrigerator, thermocautery, veterinary urine analyzer with accessories, animal sling for large animals, cold cabinet/ cold room with 25% capacity of racks as deep freezer and 75 % as cold cabinet having 2-8 degree celcius temperature, digital display, alarm system for temp. beyond set point, hematology analyzer with accessories (three parts), semi automatic veterinary serum analyzer with accessories, verticle cold cabinets for vaccine storage, with storage temperature 2-8 degree celcius. temperature holding time atleast 12 hrs, at power failure. adjustable shelves., hot air oven, incubator, ice liner (ice lined refrigerator or freezer) compressor compartment0 hermetically sealed high quality compressor 230 v 50/60 hz. relatively noise less fan to cool down the compressor. all steel tubes protected with special compound against rust formation. 1 thermostate pre-stetted from the factory for 2 c - 8 . control panel situated at the front of the unit. light indicators for different functions, 1 digital thermometer to indicate the internal temperature, latest cooling system. insulation with thick polyurethane foam. foaming agent- cyclo
Tender For electronics lab items - semiconductor & power semiconductor device trainer, rectifier, filter, zener regulator experiment trainer, power semiconductor trainer, power electronics trainer, digital multimeter 3 digit) ,4000 counts, 50mhz economy digital storage oscilloscope, pcm,dpcm / adpcm modulator and demodulator trainer, delta, adaptive delta, sigma delta, cvsd modulator & demodulator, ask, fsk, psk, qpsk bpsk modulator & demodulator, frequency modulation & demodulation techniques, am / fm radio receiver trainer, pam-ppm-pwm and line coding techniques, microwave test bench (klystron based), advanced microwave test bench (gunn based), antenna training setup (big version) antenna training system, cdma modulation / demodulation trainer, fiber optics cable trainer, 50mhz economy digital storage oscilloscope, digital multimeter 3 digit) ,4000 counts, local area network (lan) trainer kit, digital logic gates trainer, half/full adder, subtractor, alu trainer, flip flop, counters & shift register trainer, multiplexer, decoder & encoder, digital trainer, 8051/89c51 microcontroller development and training platform, arm micro controller development platform, dc/ac bridge trainer, calibration of voltmeter and ammeter trainer, calibration of wattmeter using phantom loading, lcr meter (digital), displacement sensing transducers trainer, temperature sensing transducers trainer, strain gauge transducer trainer, 50mhz economy digital storage oscilloscope, operational amplifier circuit trainer, analog to digital and digital to analog trainer, experimentation with astable and monostable multivibrator, understanding and experimentation with digital ics, digital multimeter 3 digit) ,4000 counts, lrc meter, tong tester, pcb prototype machine, voltmeter, ammeter, ammeter, dc/ac bridge trainer, dc slide wire potentiometer, cromptpn potentiometer, single phase energy meter, q-meter meter, 50mhz economy digital storage oscilloscope, displacement sensing transducers trainer, advanced microwave test bench (gunn based), fiber optics cable trainer, cdma trainer kit, plc trainer kit, control system trainer kit