Get complete information related to latest Lcd Display Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lcd Display Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lcd Display Tenders.
Tender For supply of a3 printer (print+copy+scan) automatic duplex printing + adf+input tray+multipurpo se tray+lcddisplay+hi speed usb port+ethernet 10/100 model: hp laser jet mfp m438dna or simil ar [ warranty period: 30 months after the date of delivery ]
Tender For supply of portable digital push pull gauge/digital force gauge of range 0-20 kgf lcddisplay with nabl calibration certificate similar to lutron fg 20. [ warranty period: 30 months after the date of delivery ]
Tender For supply of ultrasonic thickness gauge with lcddisplay and 02 point calibration as per enclosed technical specification [ warranty period: 30 months a fter the date of delivery ]
Tender For corrigendum : supply of intrinsicaly safe lcddisplay , portable s02 gas monitoring with sensor on top , portable nh3 gas detector , portabe gas detector f/ hydrocarbon lel
Tender For corrigendum : supply of mains detection lcddisplay controller , auto mains utility failure control modules , controller for 15 kva genset , pcb board for 2 ton split ac , pcb board for 1.5 ton window ac
Tender For corrigendum : 21/2024-25 purchase of laqshya instrument - purchase of instrument ( laqshya), radiant warmer- technical specification of radiant warmer with baby bassinet a radiant warmer is used to keep the patient s core temperature stable at 37 o c. it should be microprocessor controlled radiant warmer with manual and servo options. it should have facility to display both skin and air (ambient) temperature separately.. it should have audiovisual alarm facility for overheating beyond set temperature range. it should have alarm facility for patient temperature less than or greater than the required temperature i.e. above or below the set range. it should rotate and swivel in different direction, so as to allow taking x-ray. the light should be dazzle free. it should have alarm for power failure. it should have alarm for heater failure and auto cut off for high temp. it should have alarm for probe failure. it should have time out alarm in manual mode. it should have facility to auto reset the system in case of hang up caused by power fluctuation. it should have manual setting for high and low alarm setting. in servo mode, the heater output should be controlled to maintain the baby at the required set temperature. in manual mode, the heater output should be directly controlled by a setting on the front panel should have a facility to lock the keyboard to avoid unwanted user. the desired temperature range from 25 to 40 degree c. the resolution should be 0.1 degree c halogen based observation light should be provided for observing the baby. it should be mounted on a pole with sturdy base with lockable castors power supply: power input to be 220-240 vac, 50hz fitted with indian plug. certificate of calibration and inspection from the factory. warranty: comprehensive warranty for 5 years after warranty documentation: user, technical, maintenance manuals to be supplied ce, iso certified , fetal doppler - technical specification of fetal doppler should be compact, table type and light weight. large lcddisplay for display of fetal heart rate. back light for better visibility display signal quality, low battery, etc., high sensitivity doppler probe of frequency 2.0 mhz ultra sound intensity 10mw/cm2. built-in speaker with output not less than 1.0w should work on rechargeable batteries with minimum battery time of 300minutes. battery charger and spare set of batteries aa type to be supplied. volume control facility and audio output for ear phone should be available. heart rate range should be from 50 to 240 b pm with accuracy of + /-2% should be water proof body. should have facility for fhr data transfer to pc. doppler probe should be light weight with holder facility when not in use. should be supplied with carrying case. machine should be iso mark, baby digital thermometer - technical specification of baby digital thermometer range 0.1 to 1000 degree centigrade measurement mode- min, max, average, differential, dual temperaturereading measurement unit- degree centigrade, degree fahrenheit,kelvin temperature probe with connecting cable relative humidity10 to 90% rh non-condensing ip rating- ip 40 g) probe response time 2-3 seconds it should be who & unicef standards, fetoscope - technical specification of infant fetoscope should be 135 75mm weight should be up to 350gm should be 40cm h20 presser limiting valve inspiratory resistance should be 5cmh2o (at 50l/min), delivery trolley/patient stretcher trolley- technical specification of patient stretcher trolley overall size: 1905mm l x 710mm w x 660mm to 910 mm h. stretcher dimension 1830 mm l x 555 mm w. two section top. height adjusted by foot operated maintenance free hydraulic pump. height adjustment shall be obtained by hydraulically operated mono block type linear actuator pump foot operated actuation having stroke of 140 +/- 5 mm, push force 10 kn at 270 bars, number of complete pump stroke 22 to 24 for full stroke length x-ray permeable removable stretcher, backrest raised on
Tender For corrigendum : supply electrical consumable items for emd-3 bop & lighting section. - crc-226 contact cleaner in 415 ml/300 gram spray bottle., self adhesive pvc electric insulation tape rolls with isi mark size 1.80 cm width x 7.5 mtr length x 0.125 mm thickness, of red colour, test leads (probes) for digital multimeter, ht pvc insulation tape size 0.18 mm x25 mm x 65 mtr length, led torch, pvc twin wire 2.5mm sqr., flexible wire 2-core, 2.5 sqmm, copper flexible wire 3 cx2.5 sqmm ,1.1 kv, flat cable 3 corex4 sqmm with copper conductor for submersible motor, 1.1kv,multi stranded anealed tinned copper,epr insulated,extruded pcp sheath flexible cable size 4cx4 sqmm, wolf make air blower, vernier caliper "mitutoyo" make,size- 0- 300 mm, screw driver (tester) taparia product no:818.special with neon bulb,generally confirming to is 5579-1985 grade - ii, yellow handle,, tester type screw driver (special with neon bulb) generally confirm to is-5579-1985, grade: ii, handle- yellow colour, taparia product code-813, overall length 130 mm, combination plier, insulated with thick c.a. sleeve with joint cutter, generally confirming to is 3650-1981, product no. 1621-8., double ended fix spanner sets contant-6x7,8x9,10x11,12x13,14x15,16x17,18x19,20x22,21x23,24x27,25x28,30x32mm(12 nos),product no:14 (b) dep12, double ended ring spanners sets, ,contents- 6x7 , 8x 9, 10x11, 12x13, 14x15. 16x17 , 18x19, 20x22 , 21x23, 24x27, 25x28, 30x32 mm., socket set 1/4 " square drive(sockets-4,4.5,5,5.5,6,7,8,10,11,12,13,141/4,t20,t25,t30,t40,accessories-a733,a743,a753,a773,a703,a715), allen key set mm size (09 piece) 1.5,2,2.5,3,4,5,6,8,10 mm, bolt cutter, taperia make, length- 300mm, product no-bc-12, hydraulic hand operated crimping tool capacity : 50 to 1000 sq mm with changable hexagonal dies sets ,suitable for cu / al cable, crimping tools, capacity: 6 mm2 to 50 mm2., digital clamp on meter lcddisplay with backlight, 3-3/4 digit., din rail mounting channels, mcb 3 phase,4 pole, 63 amp 440 v ac 50 hz 10 ka
Tender For procurement of 01 no of lcddisplay for z6 (with associated hardware) for department of obstetrics & gynaecology on pac basis at aiims, bhubaneswar.
Tender For supply of installation, testing & commissioning of 10 kva online ups q-management lobby-10 kva online upssupply of installation testing & commissioning of 10 kva online ups,i>0.99 i/p power factor, 160-280 vca i/p voltage range@rated load 46-54 hz i/p frequency,0 to 40 degree operation tem, upto 93% double conversion efficiency, 192v dc voltage, automatic bypass (inbuilt), lcddisplay showing ups parameters, audible alarm: mains failure alarm, low battery alarm ups warning, overload, fault & bypass mode, with 26 ahx16 nos smf batteries, o/p voltage: 230 v during mains -voltage variation (static +/- 1% (should not be more than specified values) over loading: upto 130% for 05 minutes & upto 110% for 10 min. ups should be genset compatible, iso 9001, iso 45001 and iso 14001 certification bis (in name of ups oem), rohs type test report of the product series, ms rack required in respect to approved make-numeric/apc/emerson.