Web Analytics Made Easy - StatCounter

Lcd Module Tenders

Get complete information related to latest Lcd Module Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lcd Module Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lcd Module Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :41044325 Due date: 31 Jul, 202531 Jul, 2025 NA
Tender For bid to ras supply of micro controller c8051f 585 iq 28 qfp smd , lcd module white black light pn lm 2068e with 20 pin ffc cable , li ion 18650 7 4 v 2200 mah rechargeable bty mudole with bms circuit board , ic max 2325 v driver receiver smd , ic tca 8418 rtwr qfn 24 smd , tlv 1117 5 0 252 to voltage regulator , 20 pin ffc connector

State Government

CTN :40985778 Due date: 11 Aug, 202511 Aug, 2025 1.80 Crore
Tender For corrigendum : purchase of sports physiotherpy lab equipments - focused shockwave therapy the device should be suitable for musculoskeletal use. should be a focused shockwave based on piezo mechanism. should have multi array type piezo electric hand piece. should have accuracy of the shock wave generation cycle(frequency)0~8 10% should have software-based operating system the unit should have large color touch screen for ease of operation. the unit should have accuracy of the operating frequency 0~7000shock 10% the unit should have maximum energy density 0.702 m j/ (when setting at 23 levels) 15% should have shock wave penetration depth 40 20%. should have maximum focus size. 78 1.78 15.81 20% should have maximum pressure 44.01 0.65 mpa the unit should be supplied with piezo hand piece and elastomer gel padas of 8 different sizes, 5mm, 10mm, 15mm, 20mm, 25mm, 30mm, 35mm, and 44mm. the life span of hand piece should be of up to 10 million shocks. should be supplied with trolley with castor wheels. dimension of the device should be approximated 500mmx700mmx 1000mm should have ce or usfda certified., high laser therapy should be class iv high level laser therapy system should have a real-time operating system technology should have maximum laser should be class iv high level laser therapy system should have a real-time operating system technology should have maximum laser power output of 15 watts should have wavelengths of 810 nm & 980 nm should have an aiming beam of 650nm, should have 2 operating modes: continuous wave or pulsed applicate and piece should have embedded finger switch and light, should have a technology to customize patient treatment based on conditions, body area, body type, skin type, chronicity and absorption characteristics applicator should have a fused silica composition massage ball at the point of contact of applicator and skin. pulse frequency: 2, 10, 20, 100, 200, 500, 1000, 2500, 5000 & 10000hz pulse duration: 50% duty cycle at any given pulse frequency setting, should have a 10 hd display touch screen with password protection to reach the home screen should be supplied with 2nos. of laser protection glasses power: 100-240v, 50-60 hz the unit should be supplied with 5 different types and sizes of treatment heads (large cone, large massage ball, flat window, small massage ball, and small cone. the unit should have inbuilt battery. electrical safety class: class i, type b weight should not exceed 4 kilograms (main unit; without applicators & accessories. must have class iii also., combination therapy machine with vaccum should have 3 independent electrotherapy channels, one ultrasound channel should provide multiple clinical waveforms including interferential (2 and 4 poles and isoplanarvector), tens (asymmetric biphasic &symmetric biphasic), han, russian, vms, surged(rectangular &triangular), hvpc, microcurrent, galvanic (continuous, interrupted and low level),rabert & dia dynamic cpid/cpiso should have independent parameter adjustments for each channel including intensity, frequency, duty cycle, vector scan, channel mode, phase duration, ramp, cycle time and treatment time based on waveform should have maximum output intensity up to 140ma should have constant current and constant voltage modes should have 2 colour coded lead wires for easy picking of selected channels should have suggested electrode placement guidelines ultrasound should offer 1 and 3 mhz frequencies should have the ultrasound bnr of 5:1 or lesser should be supplied with one 5cm applicator head should have pulsed & continuous frequency modes (10%, 20%, 50% & 100%) should have variable duty cycles of 16 hz, 48 hz &1 bb 00 hz should have facility to indicate applicator uncoupling should be able to use electrotherapy and ultrasound independently and also in synchronizedcombination of electrotherapy and ultrasound, where ultrasound head functioning as bothultrasound head and electrode should have minimum

corporations/Associations/Others

CTN :41133568 Due date: 29 Jul, 202529 Jul, 2025 NA
Tender For auction sale of delector cover cap,front screen clear poly carb,relay card module,battery terminal assy jig,pressure testing and nitrogen filter,apb/pak power supply set up jig,complete pak logic module,ucg complete laser tube (laser assy),complete pak sensor module,spring laser tube tension z,case machined and finished for pak,infantry weapon effect simulator system,man wear harness (detector harness),umpire control gun with carry case,cable i/p pak road out (25mt),cable i/p pak main 230v 5a,complete ucg analog module,complete projector module,detector back plate cover,complete target locator module,cable i/p pak-battery 24vcdci/p cable,invertor 12v-240v,lcd module,socket ic 28 pin,connector pcb 1 male lock gold 8 pin,access plate assy,insulator battery acetal,transistor fet (nb 80v) bst 70a nm 80v

CTN :40955282 Due date: 18 Aug, 202518 Aug, 2025 NA
Tender For item wise procurement and supply of laboratory items for a period of 12 months - equipments, digital turbidity meter/ nephelometer -(a).parameter range- 0 to 200 & 200 to 1000 ntu*. (b). readability - 0.1 ntu & 1.0 ntu. ( c). accuracy - 3% of range. (d). repeatability - 2% of range. (e). light source - tungsten halogen lamp. (f). detector - photo diode. (g). data presentation - 31/2 digit 7 segment led of 12.7 mm height. (h). accessories - matched test tubes- 5 nos. (i). useful for determination of sulphate, phosphate, chloride, zn, ag, etc. by astm procedure. (j). extendable for measurement of inhibition growth of semantic microbial agent .brands-systronic,techlab,elko, digital conductivity meter with conductivity cell type cc-03b. (a). conductivity range : 0 to 20,200 m s*, to 2,20 & 200 m s*, (b) readability : 0.05% of range, (c) accuracy ; +_1% of range, (d) repeatability;+_1% of range, (e) data presentation: 31/2 digit 7 segment led of 12.7 mm height, (f) operating frequency: 1000hz, (g) temp. compensation: 0 to 500 c manual, (h) cell constant: 0.05, 0.1 or 1.0 (selectable), (i) out put: 20mv full scale into 10kz resistive impedance, (j) accessories: cell stand with cell holding clip.brands-systronic,techlab,elko, digital ph meter with combined ph electrode type cl - 51b (a). ph range: 0 to 14, +_1999 emf (mv), (b) readability : 0.1 ph, 1emf(mv), (c) accuracy ; +_0.01 ph, +_1 emf (mv), (d) repeatability;+_0.01 ph, +_1 emf, (e) temp. compensation: 0 to 1000 c manual, (f) data presentation: 31/2 digit 7 segment led of 12.7 mm height with polarity, (g) accessories: stand with electrode holding clamp, buffer tablets and polythine bottle, (h) physical dimensions: size 295 x 165 x 140 & weight - approximate 3, (i) manual 2 point calibration for ph, digital salinity meter (micro processor based water analyzer with magnetic stirrer), (a) measures directly ph, emf, temperature, electrolyte conductivity(ec), total dissolved solid (tds), dissolve oxygen (do), sanitary colorimeter (abs & %t) and turbidity in water sample one at a time. (b) data presentation: 2 lines 16 character dot matrix lcd modules, (c) light weight portable and easy to carry on field, (d) operates on rechargeable battery & mains supply, (e) ph: range- 0-14, readability- 0.001, accuracy - +_0.001,repeatability - +_0.1, (f) emf (mv): range- +_1999,9, readability - 0.1, accuracy - +_0.1, repeatability- +_0.1, (g) temp: range - 0-1000 c, readability - +_0.1, accuracy - +_0.5, repeatability - +_0.1, (h) ec; : range - 0-200 ms (5 ranges), readability - 0.05% of range, accuracy - +_0.1 of range, repeatability - +_0.5% of range, (i) tds: range- 0 to 100 ppt 5 range with pds factor 0.5, readability - +_0.05% of range, accuracy - +_1% of range, repeatability - +_0.5% of range, (j) do: range - 0-20, readability - 0.1, accuracy - +_0.1, repeatability - +_0.1 (k) colorimeter: range- +_2 abs & 0 to 100% t, readability - 0.001, accuracy - +_0.05 abs, repeatability - +_0.01 abs, (l) turbidity: range - 0 to 100 ntu, readability - 0.001, accuracy - +_2%, repeatability - +_0.1% (m) salinity ranger: 0 to 40 ppt, accuracy - +_1%, temp, compensation - 0 to 500c, sensor- ise (chloride) & re- bnc, (n) accessories: ce, dip type conductivity cell of 1.0 cell constant, do probe, thermo probe, magnetic stirrer, mains operated electromagnetic stirrer gi 631, stirring capsules, electrode stand with holding clamp, gas permeable membranes and 10mm & 30mm test tubes., zerological water bath superior quality(manufactures specification should be uploaded), ph meter (pocket type), brands-tamp,techlab,scientix, tds meter (pocket type) ,brands-tamp,techlab,scientix, magnetic stirrer superior quality (manufactures specification should be uploaded), heating mantle superior quality (manufactures specification should be uploaded), rainguage with measuring cylinder superior quality (manufactures specification should be uploaded), water purifier (dew drops)superior quali
 Loading, Please wait...

Connect us via What's Up