Tender For ge/smb/t-07/2025-26 repair improvement replacement to lt feeder pillar box panels and other allied connected works at zone ii and iii under mil stn samba
Tender For repair/ maint of lt distribution panel, feeder panel box, apfc panel, ug cables, and other connected works at af stn dinjan under ge (af) mohanbari
Tender For supply of electrical materials for the repair and maintenance of streetlights as per the boq - t-5 power/energy saver 2x24w choke, t-5 power/energy saver 24w ftl tuberod, 2x24 t5-holder, t5 power saver 2x24 fixture acrylic transparent cover, t5 power saver 4x24 fixture acrylic transparent cover, 150w hpsv choke, 150w hpsv lamp, capacitor 33mfd 250vac 50 hz, electronic ignitor suitable for 150w hpsv lamps, 150w holder, led driver 50w bis certified, led mcpcb plate 50w, led mcpcb plate 100w, led mcpcb plate 150w, supplyingof isi marked and approved make of moulded case circuit breaker(mccb) suitable for 3phase,3pole,50hz,415 volts, ac supply with respective interrupting capacity(ka) at 415 volts cited against their range standard conforming to is - 8828: 8.1mccb with breaking capacity 25 ka at 415 v: current rating -125 amps & 70% -100% adjustable, supply, installation, testing and commissioning of sovp device should have single high capacity varistor in the l-n plug and encapsulated spark gap for n-pe, l-n sovp should have a rated voltage of minimum 320v ac to handle indian power supply conditions. sovp should have visual indication on replaceable varistor and spark gap modules as well as a potential free contact on the socket for remote indication. sovp device should be wired up as per tt configuration of wiring in accordance with en 61643-11 standards. both the l-n and n-pe, spds should be rated for handling 30ka of nominal 8/20 s surge current.: sovp for pole light sub feeder panels - type 2 pluggable spd 3+1, rating l-n/n-pe uc 255/320 v in 30/60ka ka, lmax 30ka/60 ka, up 1.5kv, supplying of isi marked and accepted standard of miniature circuit breaker(mcb)ofcseries suitable for 240/415volts,50cycle,10 ka value ac supply confirming to is:8828:1996,iec:60898 :2002 but without enclosures: single pole 63 amp., astronomical timer with dst feature, contactor 3 pole 90 amp 50hz 415volts with no-nc contacts, tpn connector 150a, supply of approved make powder coated sheet steel encloser spn mcb db inclusive of busbar,neutral bar,earth bar & two earth terminals etc. complete as per is:13032 (exclusive of mcb & isolator): 8 way double door, supply, installation, testing and commissioning of sovp device should have single high capacity varistor in the l-n plug and encapsulated spark gap for n-pe, l-n sovp should have a rated voltage of minimum 320v ac to handle indian power supply conditions. sovp should have visual indication on replaceable varistor and spark gap modules as well as a potential free contact on the socket for remote indication. sovp device should be wired up as per tt configuration of wiring in accordance with en 61643-11 standards. both the l-n and n-pe, spds should be rated for handling 30ka of nominal 8/20 s surge current.: sovp for pole light - type 2 pluggable spd 1+1, rating l-n/n- pe uc 230/400 v in 5 ka, imax 10 ka, up 1.2kv, led batten tubelight 20w, supplying of approved make tpn mcbdb metal double door with provision for fpmcb/isolator/rccb/rcbo as incomer and sp mcbs as outgoing inclusive of busbar,neutral bar,earth bar & two earth terminals etc. complete as per is:13032 (exclusive of mcb & isolator ): 8 way (8+24), 8 sq.mm multistrand pvc insulated copper wire bundle 90mtr, 1.sq.mm aluminium single core wire bundle of 100mtr. isi marked, xlpe insulated power cable( conforming is-7098 part-1) 1100 volt grade 2-core isi marked with alu. stranded/solid conductor: 16 sq.mm unarmoured, xlpe insulated power cable( conforming is-7098 part-1) 1100 volt grade 4-core isi marked with alu. stranded/solid conductor: 16 sq.mm unarmoured, xlpe insulated power cable( conforming is-7098 part-1) 1100 volt grade 1-core isi marked with alu. stranded/solid conductor: 25sq.mm unarmoured, wooden ladder 21ft, toolkit set consisting of different sizes l-keys, screw drivers, testers and plier set., taperoll box consisting of 30pcs (conforms to is: 7809 (part 3, sec 1),self extinguishing,protects from electrolyt
Tender For corrigendum : ge/smb/t-07/2025-26 repair improvement replacement to lt feeder pillar box panels and other allied connected works at zone ii and iii under mil stn samba
Tender For special repair improvement to ht and lt transmission lines lt panels feeder box and other connected items and including other allied works for domestic area at af stn singarsi
Tender For corrigendum : s/e of 2 no. 16mt. high mast lights and cabling, repairing of lt line, s/f of ledstreetlights, repairing of ledstreetlights and high mast flood lights, s/i of 10no. water cooler and related work at nmy muzaffarnagar
Tender For corrigendum : repair replacement of old unsv led security light fittings lt ug cable brackets poles lt indoor panel outdoor feeder pillar box mccb repair and maint of lt oh ug line apfc panels lt switchgears and other connected works at alhilal mil stn
Tender For s/f of 02 nos water cooler with accessories, rep / ext of l.t. line, pole painting, tightening of over head line guarding repairing of ledstreetlight, repairing of 2 nos. high mast with old led flood light driver access etc works at nmy garaura