Get complete information related to latest Licenses Service Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Licenses Service Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Licenses Service Tenders.
Tender For electrification work in connection with provision of one common room for datalogger, eld, fuse alarm system monitoring and storing s&t critical maintenance spares at various stations/automatic huts on bsl division.
Tender For supply of various spare parts for psi department - input contactor, add on aux contact, dvr contactor, auxiliary contactor, air break, in open execution, auxiliary contactor, auxiliary contactor, auxiliary contactor, air break, in open execution, auxiliary contactor with surge suppressor, auxiliary contactor with surge varistors, open/close contactor, dc supply supvn aux contactor, aux contactor, dc contactor, dc contactor, dc contactor, aux contactor, dc contactor, aux contactor, aux. contactor, add on contact block, add on contact block, add on contact block, auxiliary contactor, auxiliary contactor, fcbcs i/p contactor, dvr contactor, dvr contactor, bch i/p contactors, bch i/p contactors, contactor, contactor, contactor, dcdb incomer contactor, winding temperature indicator, oil temperature indicator, winding temperature indicator, oil temperature indicator, remote wti/oti, for wdg temp,oil temp, for tap position, winding temperature, fire alarm, mpcb, time delay relay, rtcc supply, indication supply, out of step, trip circuit supervision, trafo fault relay, dcdb earth fault relay, transformer protection relay, mtr,86, relay, auxiliary relay, aux relay, 8 step apfc relay with rs-485 port, led indication lamp (22.5mm) (iec/is 60947-5-1), led indication lamp (22.5mm) (iec/is 60947-5-1), led indication lamp (22.5mm) (iec/is 60947-5-1), led indication lamp (22.5mm) (iec/is 60947-5-1), led indication lamp (22.5mm) (iec/is 60947-5-1), led indication lamp (22.5mm) (iec/is 60947-5-1), led indication lamp (22.5mm) (iec/is 60947-5-1), led indication lamp (22.5mm) (iec/is 60947-5-1), led indication lamp (22.5mm) (iec/is 60947-5-1), led indication lamp (10mm), 25 mm ring, door limit switch, 2.5sqmm, open/close interlock release emergency stop p.b, release emergency stop p.b, push button with spring return, push button actuator red mushroom head nonilluminated, for alarm cancellation, raise/lower command/lamp test push button, overload relay, c/o relay, bridge rectifier, counter, smps, mechnical interlock (3 lock+2 key), i/p voltmeter, o/p voltmeter, digital voltmeter with builtin selector switch, dc voltmeter, digital voltmeter with inbuilt selecter switch, digital voltmeter with inbuilt selecter switch, anolog voltmeter, o/p ammeter, battery ammeter, digital ameter with builtin selector switch size 96x96sqmm, 3 , ammeter with inbuilt selector switch., dc voltage monitoring relay, voltage monitor relay with phase sequence, voltage monitoring relay nominal, voltage monitoring relay (phase & voltage control), fcbc o/p relay, fcbc o/p relay, fcbc boost relay, fcbc voltage sensing relay, relay (air breaker auxiliary contactor relay) (relay with base), multi function meter ctr-1/5a,cl-1 with comm.port rs-485nominal voltage, 415v ac aux voltage-230v ac/ 125-250v having following parameter v, a, f, pf, power, kwh, with tod etc., multifuction meter with builtin selector switch, 230vac aux supply;96sqmm, rs-485portcl-1, digital kwh meter., digital kwh meter., digital kwh meter., on delay timer, on delay timer, on delay timer, on delay timer, hrc fuse (rectifier fuse), bs type hrc bolted/closed slot, fuse base bs type hrc bolted /off settag, bs type hrc bolted/closed slot, control circuit fuse, control fuse with base, control fuse with base, fuse link, control hbc fuse, control hbc fuse base, input fuses, rectifier fuses, capacitor fuse, fuse for lighting, motor fuse, local/remote switch, breaker control switch (trip neutral close), motor switch, auto/manual selector switch, cooler auto/manual selector, door switch, local/remote, breaker cotrol switch with key (spring return), auto/manual selector switch, auto/manual selector switch, auto/main selector switch, local/remote selector switch, vcb auxiliary switch, local/remote switch, interlock switch with mech. lock, auxialry switch, charger on/off switch- cam type front panel mounting knob handle, ac i/p voltage selector switch, breaker control switch, miniature circuit breaker, miniature cir
Tender For supply of upgradation of fmn fire fighting model room d d - composite fire extinguisher , fire blanket , stored pressured mist extinguisher , pressure monitoring system on portal fire extinguisher , combo unit fire fighting , mobile fire training unit , fire extinguisher training unit , blaze cut auto fire suppression system , video projection system , led screen for display of trg movies , auto fire alarm suspension system
Tender For supply and fixing of various materials at various type t/fs installed at various sub-stations under etd-iii, prayagraj - the following work is required for smooth operation of various type t/fs installed at various 132 kv substations under etd-iii, prayagraj., supply and fixing of winding temperature indicator (anolog type) of temp range from (0-150) oc, 5a, ac/dc both and consist of two fexible capillary tubes of 05 meter long and 03 no. mercury bulb switch for alarm, trip and cooling control system of power transformer of standard make. work includes fixing of capillary inside the temperature sensing element within the tank and proper termination of connection at both ends., supply and fixing of oil temperature indicator (analog type) of temp range (0-150) dc, sa, ac/dc both and consist of two flexible capillary tubes of 05 meter long and 03 no. mercury bulb switch for alarm & trip of power transformer of standard make. work includes fixing of capillary inside the temperature sensing element within the tank and proper termination of connection at both ends. this work also include replacement of damage oil temp indicator mounted on main tank (including all supply., the following supply & work are reqired for smooth operation of cooling fan installed at various type t/fs at various 132 kv substations, prayagraj. the details of work listed below., supply and fixing of main switch of 3p/1w, 415v, 16a rating and mcb of 4 pole, 415 16a ration for 3 phase incoming supply for cooling fans., supply and fixing of 415 volt, 16a, 4 no. contactor for main supply of cooling fans installed at various type t/fs work includes proper connection of contactor with acdb or ac cubical installed in the switchyard., supply and fixing of fan control contactors of rating 230v, 9a for auto function of cooling fans and 03 no. relays of rating 230v, 9a, 02 no-02 nc for supply monitoring for cooling fan., fixing of 3pole mcb of rating 230v, 10a to be fixed on the front side of marshaling box (mcb) provided by contractor on their own cost., supply and fiixng of thermal overload relay (type 3us5000) of rating (0.5-1a) for cooling fan of transformer on the front side of the marshaling box., wiring of all interconnection with proper ferrules and lugs of suitable size with 4mm2 flexible insulated copper conductors for power connection and with 2.5mm2 flexible insulated copper conductor for control connection in the marshaling box up to completion of works satisfactorily. (works includes supply and fixing of cable gland (all size), rail base, ferrule, lugs, supply and fixing of rubber beat for marshalling box, repairing of box with front door as required for proper operation of marshalling box, selector switch as per requirement will be provided/done by contractor on their own cost.
Tender For insulation monitoring relay rated 415 volts, 3 phase neutral isolated voltage - range 0 to 500 volts ac, insulation measuring range 0 to 500 volt ac, insulation measuring range 10 kilo ohm to 150 kilo ohm, control supply 230 volts 10%, 50 hz having fault memory test reset button and alarm lead as per rdso specification no rdso/pe/spec/0192 - 2018 (rev-1). make: m/s bender- ir 470ly-21a or equivalent of m/s abb or m/s contrel or m/s woka or m/s-sc hneider or m/s-siemens or m/s-dold or m/s-lauritz knudsen (formerly k.a l&t). (to be supplied with oem' s proof of purchase along with test certificate [ warranty period: 30 months after the date of delivery ]