Tender For supply of overhauling & maintenance of cp transformer rectifier units , ac amp. meter, for detailed description refer price breakup sheet , ac volt meter, for detailed description refer price breakup sheet , dc volt meter, for detailed description refer price breakup sheet, dc amp. meter, for detailed description refer price breakup sheet, voltmeter ( psp meter ), for detailed description refer price breakup sheet, main rectifier diodes, iav 150 amp, piv - 1200 v , type- 150 lf 120 , "lightning arrestor( la) both input and output side, rms voltage rating - 500v ,rms current rating - 1.5 ka, type- lt 0.5 oe eqv", thyrister module (scrm) consisting two antiparrallel thyrister, for detailed description refer price breakup sheet, auxiliary transformer for control circuit power supply, for detailed description refer price breakup sheet, filter capacitor bank in dc output , 2500 micro farad , 150v x 6 electrolytic capacitors, relay for providing remote contacts for mcb tripped & ac supply fail faults , coil - 240 v ac coil resistance 10 k contacts 2no+2nc , 8 pin plug in type, relay for providing remote contacts for oil tank or instrument , chamber high temp. fault. coil - 240 v ac coil resistance 10 k contacts 3no+3nc , 11 pin plug in type, thermostate with adjustable temp. setting with nc contacts ( 30 to 110 setting ), indicator lamp , housed in 22.5 mm dia, 240 v, led type red colour, auto or manual mode selector rotary type, 4 pole , 2 way ,63 amps, 240 v, ac type srpm 5417b or pa 17463b, coarse manual output control switch , rotary type, 1 pole , 6 way ,63 amps, 240 v, ac type pa7163f, fine manual output control switch rotary type, 1 pole , 4 way ,63 amps, 240 v, ac type srpm 615dor pa 5163 d, coarse current limit settor switch cam type, 2 pole ,6 way ,6 amps, 240 v, type s6-61072, fine current limit settor switch, cam type, 2 pole ,6 way ,6 amps, 240 v, type s6-61072, reference electrode selector switch, cam type 2 pole ,4 way ,6 amps, 230 v, type s6-61070, local or remote control mode selector switch,toggle type 2 pole , 2 way ,6 amps, 240 v, , on or off toggle switches in various lamp and meter circuits. 1/2 pole , 2 way ,6 amps, 240 v, , current transformer for ammeter a1 ratio - 50/1, burden - 5 va ,class - 1, contactor 32 amp.bch make 3p +(1p no) with add on 240 v ac coil , breather ( 19.45 mm dia), output voltage setter potentiometer in local auto mode 2.5 k ohm 3 watt ww, output current setter potentiometer in local auto mode 1 k ohm 3 watt ww, oil temp. indicator range ( 0 to 150 o c ), 4-20ma converter module for dc output voltage signal input - 0-75v dc , output - 4 to 20 m a , max load - 600 ohm , accuracy - +-0.5 %, aux supply - 240 v, ac type-520 t, base or channel mounting type , 4-20ma converter module for dc output current signal input - 0-75a (75 mv) dc , output - 4 to 20 m a , max load - 600 ohm , accuracy - +-0.5 %, aux supply - 240 v, ac type-520 t, base or channel mounting type , "auto transformer with coarse and fine tappings for manual control dc of output, input -265 v , coarse taps- 7 nos. fine taps- 04 nos. capacity - 8000 va, insulation - class -a (oil cooled ) ", "main transformer with shield double wound primary- 240 +/- 10 %, secondary- (0-110 v), capacity - 10,000 va, insulation - class -a (oil cooled )", filter choke in dc output , 7.5 mh at 100 amp., control box for card fixing ceco-108 & ceco 105 d1 (and extra card connector having 40 slots), current or voltage control firing card control card , type- ceco- 105d1 , "remote control interface card control card ,type- ceco -108 ", "current limit setter card control card , type- ceco -35a- 2.5 v , 75a/75mv -33.33", "voltage current sensor card control card , type -ceco -19c ", pulse driver card ceco - 118 c, surge suppressor r-c network across scrs 75 ohm, for detailed description refer price breakup sheet, "fuse fail indicator module for diodes and output fuses six channel type with led indicators and 1 common no+nc contacts ,sensing
Tender For corrigendum : procurement of spares for 220kv gis installed in dhauliganga power station - single phase common point assembly with 2 ds and 1 es type b105 without any mechanism , single phase feeder disconnector assembly with 1 ds and 2 es type b105 without any mechanism , single phase current transformer-1 line side type b105 , single phase surge arrestor type b105 , freight
Tender For supply of surge arrestor (pos no-9), as per clw spec no-clw/es/3/0016 or latest & as per abb document:- hatw 205558r0033 or latest clw drg no-clw/es/3/sk1/0016 or latest and clw/es/3/sk2/0016 or latest clw drg no- clw/es/3/sk1/0016 or latest and clw/es spec:clw spec no- clw/es/3/0016 or latest as per drg.no. clw/es/3/sk1/0016 or latest and clw/es/3/sk2/0016 specn: clw spec no-clw/es/3/0016 or latest & as per abb document:- hatw 205558r0033 or latest
Tender For corrigendum : tender for supply of bi directional amplifier and accessories : : -tetra 400 wireless bda 15dbm output , antenna ibs 380 430 mhz gain 10dbi , indoor panel antenna ibs 380 430 mhz , n male connector for 1 2 rf cable , jumper cable type rf , surge arrestor , two way power splitter 380 430mhz , power splitter , rf cable 1 2 low loss corrugated frls